22

137945_Rev_F   7.29.10

Figure 38.   Brick Kit Contents

Optional Antique Brick Kit 

# 155648

Figure 39.  

Disengage the 

compression latches 

to remove the glass 

frame.

Figure 41.  Install Side Panel

Figure 40.   Install Lower Rear Panel

CAUTION!  

THE BRICK PANELS AND LOG PARTS ARE EX-

TREMELY FRAGILE. HANDLE WITH CARE.  

Read these instructions before beginning the installation.  
1.  Remove the Top Plate. 

 Simply lift it up off of the stove 

body. It is not fastened.

2.  Remove the Glass Frame.

  Disengage the two com-

pression latches located at the top of the firebox and 

lift the glass frame up and off of the stove. See fig. 39.

3.  If installed, remove the Logset. 

 These parts are not 

fastened. Simply lift them out of the firebox. You do 

not have to remove the embers.

4.  Install the Lower Rear Panel.

  Position it up against 

the back wall, resting on the burner skirt. Fig. 40.

5.  Install a Side Panel.

  Tilt the panel, bottom edge first, 

into position against the side wall. The panel will 

stand on its own against the wall, fitting snugly be-

tween the rear panel and the front wall of the firebox. 

Fig. 41.

6.  Install the Upper Rear Panel. 

Simply rest it on the 

other two panels. Fig. 42.

7.  Install the other Side Panel.
8.  Reinstall the Logset. 

 Refer to the Owner’s Manual if 

necessary. BE CERTAIN THAT NO EMBER STONES ARE 

BLOCKING THE PILOT ASSEMBLY OPENING. Refer to fig. 

36.

9.  Replace the Glass Frame.

 Slide the frame down the 

slot in the front of the firebox. Be sure to push the 

frame into the slot in the bottom to ensure it is fully 

seated. The gasket at the top of the frame should be 

flush with the top of the firebox.

  Pull the compression latches out to engage with the 

top lip of the glass frame.

10. Replace the Top Plate.

Figure 42.  Install Upper Rear Panel

Lower Rear Panel 

220990

Right Panel 

220999

Upper Rear Panel 

220745

Left Panel 

220998

Содержание GF 300 BV

Страница 1: ...or future reference QUEFAIRESIVOUSSENTEZUNEODEURDEGAZ Ne pas tenter d allumer l appareil Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez App...

Страница 2: ...stalled and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUM...

Страница 3: ...tion 23 Illustrated Parts Breakdown 24 Replacement Parts List 25 Warranty Statement 26 Lighting Instructions 27 J tul GF BV Allagash Natural Vent Gas Stove 300 Manufactured and Distributed by J tul No...

Страница 4: ...a Propane 12 0 WC 2 99 kPa 14 9 WC 3 71 kPa Manifold Pressure MIN MAX Natural Gas 1 2 WC 30 kPa 3 8 WC 95 kPa Propane 2 9 WC 722 kPa 11 0 WC 2 74 kPa Piezo Ignitor Standing Pilot 13 330 mm Rear Exit 2...

Страница 5: ...thority in determining if a proposed installation is acceptable Any requirement that is requested by the local authority having jurisdiction that is not specifi cally addressed in this manual defaults...

Страница 6: ...ation Due to the high operating temperatures this appliance should be located out of traffic and away from furniture draperies etc Maintain proper clearance to combustible mantels and fireplace trim C...

Страница 7: ...turer s instructions and within the terms of their listing Refer to the manufacturer s instructions for approved clearances from the vent pipe to combustible materials Minimum Alcove Dimensions Mainta...

Страница 8: ...through a roof must have a flashing storm collar thimble and a Type B cap is required See diagrams page 10 Venting on the Allagash CANNOT be less than 4 in diameter or greater than 4 in diameter Any...

Страница 9: ...When installing at an altitude above 2000 the mini mum vertical rise becomes 12 from the draft hood Figure 6 GF 300 BV venting through a masonry chimney Listed termi nation cap required Storm collar...

Страница 10: ...ion cap required NOTE Installation at altitude greater than 2000 re quires minimum 12 ft vertical rise from Draft Hood NOTE Installation at altitude greater than 2000 re quires minimum 12 ft vertical...

Страница 11: ...TH THE REQUIREMENTS OF THE PRO VINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1 B149 1 AND 2 INSTALLATION CODE AVERTISEMENT CET EQUIPEMENT DE CONVERSION SERA...

Страница 12: ...e rear of the firebox When correctly positioned there will be 1 2 13 mm clearance be tween the burner plate and the front of the firebox See fig 15 11 CHANGE THE PILOT ORIFICE From within the firebox...

Страница 13: ...Install the identification labels to the stove so that they can be seen by any person that may be ser vicing the stove Label A apply to back of stove Label B apply to stove s rating plate Small valve...

Страница 14: ...2 0 14 9 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing on that system at test pressures in excess of 1 2 psig 3 5 kP...

Страница 15: ...Left Log Figure 23 Install Middle Log Figure 24 Position embers loosely and maintain 1 4 clearance from the burner skirt edges 1 4 6 mm 1 4 6 mm Pilot Assembly KEEP CARRY OVER PORTS CLEAR PN 220727 P...

Страница 16: ...ssory wiring diagram Flame Appearance Air Shutter Adjustment The GF 300 BV gas stove is shipped from the factory equipped to burn Natural gas If the stove has been converted for use with propane the A...

Страница 17: ...ated in the center of the valve face Fire intensity can be adjusted up to 50 between the LOW and HIGH settings See fig 29 NO SMOKE OR SOOT SHOULD BE PRESENT CHECK LOG PLACEMENT IF ANY SOOT OR SMOKE IS...

Страница 18: ...ure the stove is cold and there are NO hot embers 5 This appliance has a continuous burning pilot flame Exercise caution when using products having combus tible vapors Always shut off gas supply while...

Страница 19: ...e Compartment Convection Airways and optional Blower to BE CERTAIN THAT THE FLOW OF COMBUSTION AND VENTILATION AIR IS UNOBSTRUCTED The firebox should be vacuumed annually to remove any surface build u...

Страница 20: ...using the two M6 hex nuts and a 10 mm wrench See fig 34 3 Attach the Blower to the stove with the screen open ing to the rear using the two M6 flange head hex bolts as shown in fig 35 4 Attach either...

Страница 21: ...on is not desired place the blower control switch in the MANUAL position M6 x 20 mm Hex Bolts Male Quickconnector Female Figure 35 Attach Blower to the stove bottom and connect wires to Snapstat and f...

Страница 22: ...ck wall resting on the burner skirt Fig 40 5 Install a Side Panel Tilt the panel bottom edge first into position against the side wall The panel will stand on its own against the wall fitting snugly b...

Страница 23: ...equipe ment L installation n est pas propre et complete jusqu a l operation de l appareil converti est cheque suivant les criteres etablis dans les instructions de proprietaire provi sionnees avec l...

Страница 24: ...10 Figure 44 GF 300 BV Allagash Illustrated Parts Breakdown NOTE Models beginning at Serial No 30000 are configured with a front mounted gas control valve ONLY USE REPLACEMENT PARTS PROVIDED BY AN AUT...

Страница 25: ...960 64 Glass Frame 22076292 65 Glass Gasket Tadpole 129124 Replacement Glass Kit 155599 66 Firebox Heat Exchanger 221192 67 Screw 8 x 1 2 Blk 117917 68 Nut M6 Flange 2 117968 69 Exhaust Baffle 220763...

Страница 26: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Страница 27: ...knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this appl...

Страница 28: ...ginning the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in spec...

Отзывы: