![Jøtul GF 300 BV Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/jotul/gf-300-bv/gf-300-bv_installation-and-operation-instructions-manual_2037795020.webp)
20
137945_Rev_F 7.29.10
Optional Blower # 155620
Figure 33. Blower Kit Components
THIS BLOWER MUST BE ELECTRI-
CALLY GROUNDED IN ACCOR-
DANCE WITH LOCAL CODES OR, IN
THE ABSENCE OF LOCAL CODES,
WITH THE CURRENT ANSI/NFPA
70, NATIONAL ELECTRICAL CODE
OR CSA C22.1-CANADIAN ELECTRI-
CAL CODE.
THIS UNIT IS SUPPLIED WITH
A THREE-PRONG (GROUNDING)
PLUG FOR PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO A PROP-
ERLY GROUNDED THREE-PRONG
RECEPTACLE. DO NOT CUT OR
REMOVE THE GROUNDING PRONG
FROM THE PLUG.
ALWAYS DISCONECT THE POWER
SUPPLY WHEN PERFORMING ANY
SERVICE ON THE FIREPLACE IN-
SERT.
1. Unpack and check the contents
of the blower kit.
Contact your dealer if any damage is evident or parts
are missing. See fig. 33.
2. Attach the Snapstat Bracket
to the studs located un-
derneath the stove in the middle of the firebox floor
using the two M6 hex nuts and a 10 mm wrench. See
fig. 34.
3. Attach the Blower
to the stove with the screen open-
ing to the rear using the two M6 flange head hex
bolts as shown in fig. 35.
4. Attach either Snapstat wire connector
to either
Snapstat terminal. See fig. 35.
5. Install the Snapstat
by sliding it all the way into the
slot in the Snapstat Bracket as shown in fig. 34.
6. Connect the female Control Switch
quick-connector
to the male control switch wire harness already
installed in the stove. See fig. 35.
7. Connect power cord
to the nearest outlet.
Contents
1. Blower
2. Snapstat Wire Harness
3. Control Switch Wire Harness
4. Snapstat
5. Snapstat Bracket
6. M6 Flange Nuts, (2)
7. M6 x 12 Hex Bolts, (2)
Tools Required
• 10 mm wrench
Figure 34. Attach Snapstat Bracket.
Snapstat
Bracket
Hex Head
Flange Nuts
CONNECT THE GAS SUPPLY TO THE
STOVE BEFORE INSTALLING THIS
BLOWER. IF NECESSARY, USE A 90°
ELBOW OFF THE GAS VALVE TO CREATE
ADEQUATE GAS LINE CLEARANCE.
BE SURE ALL WIRE CONNECTIONS
HAVE BEEN MADE BEFORE
CONNECTING TO POWER SUPPLY.
2
3
6
5
4
1
7