High Altitude Adjustment

Installations burning natural gas and located at altitudes 

from 2000 - 4500 ft. (610 M - 1370 M), require compensa-

tion for the thinner air (less volume of air per cubic foot). 

Higher altitudes affect the atmospheric pressure and heat 

value of gaseous fuels.  The lower oxygen content in the 

air and the lower gas viscosity require the use of a differ-

ent orifice to achieve efficient, clean combustion at the 

burner tube.  

For high altitude installations consult the local gas 

distributor or the authority having jurisdiction for proper 

rating methods.  If the installer must convert the unit to 

adjust for varying altitudes, 

use Jøtul High Altitude Kit, 

#155810-NG.  

DO NOT DERATE THE BURNER FOR PROPANE.

In the U.S:  

THE DERATING KIT MUST BE INSTALLED BY 

AN AUTHORIZED SERVICE TECHNICIAN IN ACCORDANCE 

WITH THE MANUFACTURER’S INSTRUCTIONS AND ALL 

CODES AND REQUIREMENTS OF THE AUTHORITY HAV-

ING JURISDICTION. THE INFORMATION STICKER MUST 

BE COMPLETED BY THE INSTALLER AND APPLIED TO THE 

APPLIANCE AT THE TIME OF THE CONVERSION. THE QUALI-

FIED SERVICE AGENCY PERFORMING THIS WORK ASSUMES 

RESPONSIBILITY FOR THIS DERATING.

In Canada: 

This unit has been tested for installation at 

high altitudes in accordance with Canadian test standard 

CAN/CGA-2.17. THE DERATING SHALL BE CARRIED OUT IN 

ACCORDANCE WITH THE REQUIREMENTS OF THE PROVIN-

CIAL AUTHORITIES HAVING JURISDICTION AND IN ACCOR-

DANCE WITH THE REQUIREMENTS OF THE CAN1-B-149.1 

AND .2 INSTALLATION CODE.

 

 

AVERTISEMENT:

Cet equipement de conversion sera installe par une 

agence qualkfiee de service conformenment aux instruc-

tions du fabricant et toutes exigences et codes apple-

cables de l’autorises avoir la juridiction.  Si l’informaiton 

dans cette Instruction n’est pas suivie exactement, un 

feu, explosion ou production de protoxyde de carbone 

peut resulter le dommages causer de propriete, perte ou 

blessure personnelle de vie.  L’agence qualifiee’ de service 

est esponsable de l’installation propre de cet equipe-

ment.  L’installation n’est pas propre et complete jusqu’a 

l’operation de l’appareil converti est cheque suivant les 

criteres etablis dans les instructions de proprietaire provi-

sionnees avec l’equipement.  

Derating Procedure

1.  Follow Steps 1-10 of the Fuel Conversion procedure 

outlined on pages 11 and 12.

2.  Replace the original orifice with the #40 orifice in the kit.

3.  Fill out the high altitude conversion label from the kit 

and attach to the rating plate or gas valve.

4.  Reassemble the firebox components.

5.  It may be necessary to adjust the air shutter on the 

burner tube.  See AIR SHUTTER/FLAME APPEARANCE on 

page 16 for more details.

Figure 43.  Change the Burner Orifice.

Replace with #40 

orifice 

Mobile Home Installation

The GF 300 BV can be installed for use in a mobile home 

in the U.S. and Canada provided:
1.  The stove is secured to the floor of the mobile home. 

Use Jøtul Floor Bracket Kit #750304.

2.  Provision must be made to secure an electrical ground 

between the stove and the mobile home chassis.

3.  The stove is installed in accordance with Title 24 CFR, 

Part 3280-  Manufactured Home Construction and 

Safety Standard, in the U.S. In Canada, comply with CSA 

Z240.4, Gas Equipped Recreational Vehicles and Mobile 

Housing.

4.  Always contact your local officials about installation 

restrictions and requirements in your area.

THIS APPLIANCE MAY BE INSTALLED AS AN OEM INSTALLA-

TION IN A MANUFACTURED (MOBILE) HOME AND MUST 

BE INSTALLED IN ACCORDANCE WITH THE MANUFAC-

TURER’S INSTRUCTIONS AND THE MANUFACTURED HOME 

CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, 

PART 3280. THIS APPLIANCE IS ONLY FOR USE WITH THE 

TYPE OF GAS THAT IS INDICATED ON THE STOVE’S RATING 

PLATE.  A GAS CONVERSION KIT IS PROVIDED WITH THE GF 

300 DV GAS STOVE.

THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMAR-

KET PERMANENTLY LOCATED, MANUFACTURED (MOBILE) 

HOME, WHERE NOT PROHIBITED BY LOCAL CODES. 

CET APPAREIL PEUT ETRE INSTALLE DANS UN MAISON 

PREFABRIQUEE (MOBILE) DEJA INSTALLEE A DEMEURE SI 

LES REGLEMENTS LOCAUX LE PERMETTENT.  CET APPAR-

EIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE 

GAS INDIQUES SUR LA PLAQUE SIGNALETIQUE.  NE PAS 

L’UTILISER AVEC D’AUTRES GAS SAUF SI UN KITDE CON-

VERSION CERTIFIE EST INSTALLE.

Содержание GF 300 BV

Страница 1: ...or future reference QUEFAIRESIVOUSSENTEZUNEODEURDEGAZ Ne pas tenter d allumer l appareil Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez App...

Страница 2: ...stalled and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUM...

Страница 3: ...tion 23 Illustrated Parts Breakdown 24 Replacement Parts List 25 Warranty Statement 26 Lighting Instructions 27 J tul GF BV Allagash Natural Vent Gas Stove 300 Manufactured and Distributed by J tul No...

Страница 4: ...a Propane 12 0 WC 2 99 kPa 14 9 WC 3 71 kPa Manifold Pressure MIN MAX Natural Gas 1 2 WC 30 kPa 3 8 WC 95 kPa Propane 2 9 WC 722 kPa 11 0 WC 2 74 kPa Piezo Ignitor Standing Pilot 13 330 mm Rear Exit 2...

Страница 5: ...thority in determining if a proposed installation is acceptable Any requirement that is requested by the local authority having jurisdiction that is not specifi cally addressed in this manual defaults...

Страница 6: ...ation Due to the high operating temperatures this appliance should be located out of traffic and away from furniture draperies etc Maintain proper clearance to combustible mantels and fireplace trim C...

Страница 7: ...turer s instructions and within the terms of their listing Refer to the manufacturer s instructions for approved clearances from the vent pipe to combustible materials Minimum Alcove Dimensions Mainta...

Страница 8: ...through a roof must have a flashing storm collar thimble and a Type B cap is required See diagrams page 10 Venting on the Allagash CANNOT be less than 4 in diameter or greater than 4 in diameter Any...

Страница 9: ...When installing at an altitude above 2000 the mini mum vertical rise becomes 12 from the draft hood Figure 6 GF 300 BV venting through a masonry chimney Listed termi nation cap required Storm collar...

Страница 10: ...ion cap required NOTE Installation at altitude greater than 2000 re quires minimum 12 ft vertical rise from Draft Hood NOTE Installation at altitude greater than 2000 re quires minimum 12 ft vertical...

Страница 11: ...TH THE REQUIREMENTS OF THE PRO VINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1 B149 1 AND 2 INSTALLATION CODE AVERTISEMENT CET EQUIPEMENT DE CONVERSION SERA...

Страница 12: ...e rear of the firebox When correctly positioned there will be 1 2 13 mm clearance be tween the burner plate and the front of the firebox See fig 15 11 CHANGE THE PILOT ORIFICE From within the firebox...

Страница 13: ...Install the identification labels to the stove so that they can be seen by any person that may be ser vicing the stove Label A apply to back of stove Label B apply to stove s rating plate Small valve...

Страница 14: ...2 0 14 9 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing on that system at test pressures in excess of 1 2 psig 3 5 kP...

Страница 15: ...Left Log Figure 23 Install Middle Log Figure 24 Position embers loosely and maintain 1 4 clearance from the burner skirt edges 1 4 6 mm 1 4 6 mm Pilot Assembly KEEP CARRY OVER PORTS CLEAR PN 220727 P...

Страница 16: ...ssory wiring diagram Flame Appearance Air Shutter Adjustment The GF 300 BV gas stove is shipped from the factory equipped to burn Natural gas If the stove has been converted for use with propane the A...

Страница 17: ...ated in the center of the valve face Fire intensity can be adjusted up to 50 between the LOW and HIGH settings See fig 29 NO SMOKE OR SOOT SHOULD BE PRESENT CHECK LOG PLACEMENT IF ANY SOOT OR SMOKE IS...

Страница 18: ...ure the stove is cold and there are NO hot embers 5 This appliance has a continuous burning pilot flame Exercise caution when using products having combus tible vapors Always shut off gas supply while...

Страница 19: ...e Compartment Convection Airways and optional Blower to BE CERTAIN THAT THE FLOW OF COMBUSTION AND VENTILATION AIR IS UNOBSTRUCTED The firebox should be vacuumed annually to remove any surface build u...

Страница 20: ...using the two M6 hex nuts and a 10 mm wrench See fig 34 3 Attach the Blower to the stove with the screen open ing to the rear using the two M6 flange head hex bolts as shown in fig 35 4 Attach either...

Страница 21: ...on is not desired place the blower control switch in the MANUAL position M6 x 20 mm Hex Bolts Male Quickconnector Female Figure 35 Attach Blower to the stove bottom and connect wires to Snapstat and f...

Страница 22: ...ck wall resting on the burner skirt Fig 40 5 Install a Side Panel Tilt the panel bottom edge first into position against the side wall The panel will stand on its own against the wall fitting snugly b...

Страница 23: ...equipe ment L installation n est pas propre et complete jusqu a l operation de l appareil converti est cheque suivant les criteres etablis dans les instructions de proprietaire provi sionnees avec l...

Страница 24: ...10 Figure 44 GF 300 BV Allagash Illustrated Parts Breakdown NOTE Models beginning at Serial No 30000 are configured with a front mounted gas control valve ONLY USE REPLACEMENT PARTS PROVIDED BY AN AUT...

Страница 25: ...960 64 Glass Frame 22076292 65 Glass Gasket Tadpole 129124 Replacement Glass Kit 155599 66 Firebox Heat Exchanger 221192 67 Screw 8 x 1 2 Blk 117917 68 Nut M6 Flange 2 117968 69 Exhaust Baffle 220763...

Страница 26: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Страница 27: ...knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this appl...

Страница 28: ...ginning the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in spec...

Отзывы: