6.3 Chimney System

The Jøtul F 500 V3 is designed to burn cleanly and 

efficiently when used according to the guidelines in this 

manual.  In order to maintain proper performance, you 

should inspect the chimney and chimney connector at the 

beginning of each heating season and then every other 

month during the heating season. Clean the chimney 

whenever creosote and fly ash accumulation exceeds 1/4 

inch in any part of the system.

Chimney brushes are available from your local Jøtul 

dealer or hardware supply store. Your dealer can also 

refer you to a reputable, professional chimney sweep 

who will have all the equipment to ensure a complete 

and proper job. Failure to keep the chimney system 

free of creosote and build-up could result in a serious 

chimney fire.

6.4 Enamel Care

•  DO NOT ATTEMPT TO CLEAN HOT ENAMEL SURFACES. 

Clean only cold enamel surfaces with a soft damp cloth 

and polish with a clean dry cloth. Most stains can be 

removed with a solution of baking soda and vinegar.  Let 

this solution sit on the stain for a minute or two before 

rubbing it dry with a damp cloth. Organic cleaning 

commercial cleaning solutions, such as Citra-Solv®, can 

also be effective.

•  DO NOT USE SOAPY OR ABRASIVE SOLUTIONS. These can 

cause stains. Coffee, tea, and fruit jucies will also cause 

stains.

•  AVOID CONTACT WITH METAL OBJECTS. Trivets, kettles, 

or pots, can damage the enamel

 WARNING: 

 

DO NOT OPERATE THIS STOVE WITH THE ASH 

DOOR OPEN. 

  This condition will lead to overfiring which is 

dangerous and can damage the stove. Such 

damage is not covered under warranty. Only 

empty the ash drawer before refueling, when 

the fire is low or extinguished. The ash door 

should be open only long enough to empty the 

drawer and then securely closed. Inspect the 

gasket on the ash pan door regularly and replace 

as necessary. 

 

6. Maintenance

See Appendix A, page 24, for 

Combustor Maintenance and 

Replacement instructions. 

Regular maintenance will prolong the life of your 
stove and ensure satisfactory performance. 

6.1 Annual Stove Inspection

•  Empty stove of all soot and ashes. Only use a 

vacuum for this job if the vacuum is specifically 

designed to handle ashes.

•  Inspect the stove seams. Use a utility light to 

inspect the stove inside and out for cracks or 

leaks.  Replace all cracked parts and repair any 

cement leaks with furnace cement.  Always wear 

safety gloves when handling the ash pan. 

•  Inspect the Catalytic Combustor. See Appendix A, 

page 24.

6.2 Ash removal

Ash removal will be required periodically 

depending on how frequently the stove is used. 

Conveniently, the Jøtul F 500  V3 is equipped with 

an ash pan for easy ash removal without the 

need to open the front door.  

  The ash pan door is located under the front 

ashlip of the stove. To open the ash door, rotate 

the door handle counterclockwise to unlatch the 

door and clockwise to latch the door.  Always use 

stove gloves when handling the ash pan. Always 

close the ash door before leaving to dispose of 

the ashes when the stove is burning. 

    Ashes should be placed in a metal container 

equipped with a tight sealing lid. The container 

should be placed on a noncombustible floor or 

on the ground, well away from all combustible 

materials, pending final disposal. If the ashes are 

disposed of by burial in soil or otherwise locally 

dispersed, they should be retained in the closed 

container until all cinders have thoroughly cooled. 

Only use a vacuum for this job if the vacuum is 

specifically designed for ashes. 

    It is advisable to always keep a one inch  bed 

of ashes on the firebox floor to help maintain a 

hot charcoal bed and insulate the bottom.

Содержание Classic F 500 V3

Страница 1: ...make them available to anyone using or servicing this wood heater This wood heater contains a catalytic combustor that requires periodic inspection and repair for proper operation See this manual for...

Страница 2: ...tove Inspection 13 6 2 Ash Removal 13 6 3 Chimney System 13 6 4 Enamel Care 13 6 5 Glass Care Glass Replacement 14 6 6 Gaskets 14 7 Accessories 15 8 Illustrations Figures 16 21 Clearance Chart and Dia...

Страница 3: ...NDING WHEN ADDING FUEL Avoid creating a low pressure condition in the room where the stove is operating Be aware that operation of an exhaust fan or clothes dryer can create a low pressure area and co...

Страница 4: ...ws The maximum horizontal run is 36 915mm and a recommended total length of stove pipe should not exceed 10 feet Horizontal runs must slope upward 1 4 6 35mm per foot toward the chimney Where passage...

Страница 5: ...collar Larger chimney flues should be relined with a listed or code approved liner The masonry chimney must have a fireclay liner or equivalent with a minimum thickness of 5 8 16mm and must be instal...

Страница 6: ...be installed to resize the flue The fireplace installation must also conform to the tested clearances to surrounding trim and mantels See clearance specifications on pages 22 23 In addition a fireplac...

Страница 7: ...50 5 deep 1168mmx1283mm can be used only if the left side door is locked to prevent use Door Lock Kit 155850 is available for this purpose from your dealer 4 2 Clearances to Walls and Ceilings The fo...

Страница 8: ...ned 2 All chimney components including chimney sections supports spark arrestor etc shall comply with the Standard for Factory built Chimneys for Residential Type and Building Heating Appliances UL 10...

Страница 9: ...as the stove The monitor should be located as far away as possible from the stove to avoid alerts when the doors are opened 5 3 Wood Fuel and Performance Use dry wood The F 500 V3 is designed to burn...

Страница 10: ...d into the atomosphere When the combustor is functioning no smoke will be observed exiting the chimney This is evidence that the stove is operating in the so called sweet spot wherein optimum efficien...

Страница 11: ...or the most efficient burn is between 400 and 600 204 C 316 C 2 Take the magnet off of thermometer and replace into the correct orientation as shown in fig 13c 13e 3 Place the thermometer fully into h...

Страница 12: ...full open position far right To minimize any smoke spillage open the door slightly before opening fully This will allow air flow to stabilize within the firebox and chimney flue Use a stove tool or po...

Страница 13: ...h to empty the drawer and then securely closed Inspect the gasket on the ash pan door regularly and replace as necessary 6 Maintenance See Appendix A page 24 for Combustor Maintenance and Replacement...

Страница 14: ...pattern as you would tighten the lugs on an automobile wheel 6 6 Gaskets Check door and glass panel gaskets for tightness To check the seal of the front door close and latch the door on a dollar bill...

Страница 15: ...ed with Rear Heat Shield 154332 not included Outside Air Kit 154335 Provision for outside air may be required by your local building codes The outside air kit includes a 3 inch adapter used to connect...

Страница 16: ...F 500 V3 Oslo 4 20 16 Fig 1a Fig 1b Fig 4 Masonry chimney penetration Fig 3 Chimney height 3 2 10 Rule Fig 2 Chimney connector assembly 8 Illustrations Fig 5 Chimney thimble components 24 3 4 629mm...

Страница 17: ...ns 2 50 mm Min width 50 5 1283mm Min width 56 1422 mm 18 460 mm 8 200 mm 8 200 mm 18 460 mm Min depth 50 1 2 1283 mm Min width 54 1 4 1378 mm Fig 6 Fireplace chimney construction Fig 7 Prefabricated c...

Страница 18: ...ature Monitor FULLY CLOSED FAR LEFT FULLY OPEN FAR RIGHT Combustion Monito r DO NOT REMOVE THIS SET SCREW Fig 13b Fig 13c Removemagnetfromcurrentorientation Fig 13d Orient magnet Incorrect Orientation...

Страница 19: ...e bottom 1 Bend the flattened heat shield on the perforations as shown painted side down 2 Use a 10 mm wrench to remove the two bolts from the bottom of the ash compartment Unpainted Side Up Fig 16 Bo...

Страница 20: ...F 500 V3 Oslo 4 20 20 F 500 V3 Illustrated Parts Breakdown Purchase replacement parts only from a J tul Authorized dealer...

Страница 21: ...le Cast Straight 10243892 31 Spring Door Handle 126164 32 Coiled Spring Pin 5x24 118070 33 Washer Door Handle 117587 34 Gasket Round LD2 375 Graphite 225695 35 Insulation Blanket Burn Plates 128903 36...

Страница 22: ...e Protected surface Single wall pipe 18 460mm 12 300mm Double wall pipe 6 150mm 6 150mm Fireplace Mantle and Trim Clearance no shielding reduction permitted Stove Side to Side Trim 1 thick or less 12...

Страница 23: ...ce Parallel to the Wall Unprotected Surface Corner Installation Protected Surface Corner Installation E F A G C F A G F A D F D D D B F F F F D A D F D D D F D D PER NFPA 211 or CAN CSA B365 Important...

Страница 24: ...periodically monitor the operation of the catalytic combustor to ensure that it is functioning properly and to determine when it needs to be replaced A non functioning combustor will result a loss of...

Страница 25: ...nd the front plate inside the stove as in fig 19 2 Use the 3mm hex key to remove the two M6x40 set screws on the left and right sides See fig 20 2 Wearing gloves grasp each side and lift the front of...

Страница 26: ...F 500 V3 Oslo 4 20 26 Fig 24 Left and Right Side insulation panel removal and replacement Fig 23 Lift combustor from the chamber Expansion gasket RRefactory member...

Страница 27: ...lue 3 If the overall R value of the system is greater than the R value of the specified floor protector the alternate is acceptable Example The specified floor protector should be 3 4 thick material w...

Страница 28: ...sions and Limitations Notice This warranty is void if installation or service is performed by someone other than an authorized installer or service agency or if installation is not in conformance with...

Страница 29: ...EASONABLY COULD HAVE BEEN DISCOVERED This warranty is given by J tul North America Inc 55 Hutcherson Drive Gorham Maine 04038 USA Return to Applied Ceramics Customer Service Department 5555 Pleasantda...

Страница 30: ...eplacement STEEL COMBUSTOR fails to function the prorated warranty will allow replacement at the following special price schedule Year 3 130 00 Year 4 140 00 Year 5 150 00 Year 6 160 00 Year 7 and aft...

Страница 31: ...F 500 V3 Oslo 4 20 31 This page is intentionally left blank...

Страница 32: ...box 1411 N 1602 Fredrikstad Norway www jotul us 139946_R10 April 2020 For Your Records Record the following information to help your dealer determine what you will need should your stove ever require...

Отзывы: