4.5 GENERAL ALARM
INTERFACE TO SHIP WHISTLE/SIREN
In order to use the ship whistle as a part of the General Alarm system the Compact MPA is providing a dry closing contact
(NO) output that generates a control output signal synchronised with the GA tone sequence at terminals 82 and 84. Ref.
drawing in 9.3.
4.6 MUTE OF EXTERNAL GENERAL ALARM
DURING EMERGENCY PA
During an active Emergency PA, the Compact MPA outputs a dry closing contact (NO) output at terminals 85 and 87 as a
mute signal for an alternative external GA system. This signal is activated together with the internal GA mute functionality.
4.7 GENERAL ALARM
WARNING (FLASHING) LIGHT
An active General Alarm in the Compact MPA system is also indicated with a dry closing contact (NO) output at terminals 66
and 68 for activation of external GA warning lights. This is mandatory in high noise environments. Ref. drawing in 9.3.
140
Power -
142
Audio +
User Interface 4
Bidirectional
Electronically balanced audio input
2Vrms
15k Ω
144
Audio -
146
RS485 -
Bidirectional
Data communication tranceiver
channel RS485
5V
100 Ω
148
RS485 +
150
Power +
Output
Power supply output
24VDC
140 mA
152
Power -
153
Audio +
Mic. Station 1
Input
Electronically balanced audio input
10 mV
5 kΩ
155
Audio -
157
PTT
Dry contact input
≈20 VDC
2 mA
159
PTT ref-
154
Audio +
Mic. Station 2
Input
Electronically balanced audio input
10 mV
5 kΩ
156
Audio -
158
PTT
Dry contact input
≈20 VDC
2 mA
160
PTT ref-
161
485 -
RS 485
(To amp 1671)
Bidirectional
Data communication tranceiver
channel RS485
5V
100 Ω
163
485 +
165
485 -
Data communication tranceiver
channel RS485
5V
100 Ω
167
485 +
169
485 -
Data communication tranceiver
channel RS485
5V
100 Ω
171
485 +
162
RX B
RS 422 – RX
(Not used)
164
RX A
166
RX B
168
RX A
170
RX B
172
RX A
173
100V_P
100V line from amplifier
(Zone 1 / Relay 1)
Input
100VAC
2.5A
174
100V_N
100VAC
2.5A
175
100V_P
100V line from amplifier
(Zone 2 / Relay 2)
Input
100VAC
2.5A
176
100V_N
100VAC
2.5A
177
100V_P
100V line from amplifier
(Zone 3 / Relay 3)
Input
100VAC
2.5A
178
100V_N
100VAC
2.5A
179
100V_P
100V line from amplifier
(Zone 4 / Relay 4)
Input
100VAC
2.5A
180
100V_N
100VAC
2.5A
181
100V_P
100V line from amplifier
(Zone 5 / Relay 5)
Input
100VAC
2.5A
182
100V_N
100VAC
2.5A
183
100V_P
100V line from amplifier
(Zone 6 / Relay 6)
Input
100VAC
2.5A
184
100V_N
100VAC
2.5A
All cables used for external interfaces are to be twisted pair, outer screen, 0.75 mm² minimum.
Содержание MPA 1600
Страница 21: ...22 User and Installation Manual Compact MPA DNH HP15T...
Страница 50: ...51 User and Installation Manual Compact MPA 9 ANNEX A 9 1 COMPACT MPA CABINET MECHANICAL LAYOUT...
Страница 51: ...52 User and Installation Manual Compact MPA 9 2 WALL BRACKET KIT...
Страница 53: ...54 User and Installation Manual Compact MPA 9 3 COMPACT MPA CABINET EXTERNAL CONNECTION...
Страница 54: ...55 User and Installation Manual Compact MPA...
Страница 62: ...www jotron com...