4. Steriliza�on Func�on ---- Free from Cross-contamina�on
5.
Nebulizer
Treatment Func�on---- Making the Treatment More Convenient
6. Oxygen Concentra�on Monitoring Systems----A Defense Line to Guard Life
The above test report shows that: the nearby negative-ion concentration of
JorVet J1550 ICU Unit
is up
to 6 million ones/cm
3
standard, which has reached the medical-level Negative-ion emission standard.
It is truly air purifying, and is effectively helpful for the rehabilitation and recovery of pets.
A UVC ultraviolet ray is the one that truly has germicidal effect, and C ultraviolet of which is easily
absorbed by DNA of organisms, especially, ultraviolet ray of 253.7nm is the best. UV sterilizer is a
purely physical method of disinfection, which is characterized by simple and convenient operation, high
efficiency, no secondary pollution, easy for management and automation etc.
JorVet ICU Unit
uses ultraviolet sterilizer, which is characterized by strong radiation
intensity, high
stability and high transmittance to quartz glass tube. The transmittance is of ≥87% and the radiation
intensity is at 253.7-254μm and remains stable. Furthermore, high brightness mirror
sterilization
reaction chamber design is adopted. Compared with similar products from abroad, the sterilization
strength increases by 18% - 27%.
---- Generally, the bactericidal action of ultraviolet ray on bacteria and viruses can achieve sterilization
rate of 99% - 99.9% in one to two seconds.
---- The broad-spectrum of ultraviolet sterilization is the highest, and it can efficiently kill almost all
bacteria and viruses.
---- The ultraviolet sterilizer has no secondary pollution. No chemicals will be added in ultraviolet
sterilization, thus, water and its surrounding environment will not be polluted secondly. Furthermore, it
will not change any ingredients in the water.
---- The operation of ultraviolet sterilizer is safe and reliable: traditional disinfection technologies such
as chloride or ozone, the disinfectants themselves are highly toxic and flammable substances, while
there is no such potential safety hazard in ultraviolet sterilization system.
JorVet ICU Unit
is equipped with an external silent medical atomizer, and biomedical engineering
research shows: when the atomized particles are about 10 microns, medicines can only deposit in
the mouth and throat, when the atomized particles are about 3-6 microns, medicines can enter into the
bronchus, and when the atomized particles are less than 2 microns, medicines can enter into the finest
bronchus and alveoli. The
JorVet J1550 ICU Unit
can produce 0.5-4 micron atomized particles of
medicine. Meanwhile, intelligent control quantity of atomization is provided for your selection,
and the maximum atomizing volume is up to 0.5ml/min. The atomization in the ICU is even,
and the inhalation effect of atomized medicines is obvious. The medical atomizer is
characterized by low noise, which complies with pet ICU noise standard.
An increase in carbon dioxide concentration is accompanied by a decrease in oxygen concentration. Being
anoxic under low oxygen and high concentration of carbon dioxide for a long time will cause pulmonary
edema, cerebral edema, metabolic acidosis, electrolyte imbalance, shock, hypoxic encephalopathy, etc.
When the carbon dioxide concentration reaches 1000PPM above, it will cause dizziness, drowsiness and
reduced resistance to pets; when the carbon dioxide concentration reaches 2000-5000PPM, it will cause
mild nausea, poor breathing, rapid heartbeat and electrolyte imbalance to pets, and seriously affect the
health of pets and their postoperative rehabilitation; and when the carbon dioxide concentration is over
5000PPM, it will cause severe hypoxia, coma and even death.
08
09
The negative ion generator boosts low voltage to negative high voltage DC through the voltage
booster circuit. DC high voltage from the tip of carbon brush is used to produce high corona and
lots of high-speed electrons are released. Since electronics cannot exist in the air for a long time
(the life of existing electrons is n S level), they will be captured by oxygen molecules (O
2
) in the air
immediately, and then negative ions are formed; the working principle of which is the same as
natural phenomenon (negative ions are produced when there is thunder and lightning).
Test equipment: KEC-990 air ion concentration tester, HG3830 high voltage test bench
In case of no electricity, no abnormalities occur after
being placed for 72 hours at ambient temperature of
+25°C and relative humidity of 95%.
In case of no electricity, no abnormalities occur after
being placed for 72 hours at ambient temperature of
+70°C
In case of no electricity, no abnormalities occur after
being placed for 72 hours at ambient temperature
of-20°C.
Starting at 100cm (39.37”) from the ground, free fall onto
the board, it will still function properly.
Drop test
II Principle of Operation
Low-temperature
characteristics
High-temperature
characteristics
Humidity resistance
Storage temperature
Operating humidity range
Operating temperature range
-20°C~+70°C
40%~85%
-10°C~+40°C
Rated power
Input current
<
1W
<
80mA