Jorvet J1550 Скачать руководство пользователя страница 6

4. Steriliza�on Func�on ---- Free from Cross-contamina�on

5. 

Nebulizer

 Treatment Func�on---- Making the Treatment More Convenient

6. Oxygen Concentra�on Monitoring Systems----A Defense Line to Guard Life

The above test report shows that: the nearby negative-ion concentration of 

JorVet  J1550  ICU  Unit

 is up 

to 6 million ones/cm

3

 standard, which has reached the medical-level Negative-ion emission standard. 

It is truly air purifying, and is effectively helpful for the rehabilitation and recovery of pets.

A UVC ultraviolet ray is the one that truly has germicidal effect, and C ultraviolet of which is easily 
absorbed by DNA of organisms, especially, ultraviolet ray of 253.7nm is the best. UV sterilizer is a 
purely physical method of disinfection, which is characterized by simple and convenient operation, high 
efficiency, no secondary pollution, easy for management and automation etc.

JorVet ICU Unit

 uses ultraviolet sterilizer, which is characterized by strong radiation 

intensity, high 

stability and high transmittance to quartz glass tube. The transmittance is of ≥87% and the radiation 
intensity is at 253.7-254μm and remains stable. Furthermore, high brightness mirror 

sterilization 

reaction chamber design is adopted. Compared with similar products from abroad, the sterilization 
strength increases by 18% - 27%.
---- Generally, the bactericidal action of ultraviolet ray on bacteria and viruses can achieve sterilization 
rate of 99% - 99.9% in one to two seconds.
---- The broad-spectrum of ultraviolet sterilization is the highest, and it can efficiently kill almost all 
bacteria and viruses.
---- The ultraviolet sterilizer has no secondary pollution. No chemicals will be added in ultraviolet 
sterilization, thus, water and its surrounding environment will not be polluted secondly. Furthermore, it 
will not change any ingredients in the water.
---- The operation of ultraviolet sterilizer is safe and reliable: traditional disinfection technologies such 
as chloride or ozone, the disinfectants themselves are highly toxic and flammable substances, while 
there is no such potential safety hazard in ultraviolet sterilization system.

JorVet  ICU  Unit

 is  equipped  with  an  external  silent  medical  atomizer,  and  biomedical  engineering 

research shows: when the atomized particles are about 10 microns, medicines can only deposit in 
the mouth and throat, when the atomized particles are about 3-6 microns, medicines can enter into the 
bronchus, and when the atomized particles are less than 2 microns, medicines can enter into the finest 
bronchus  and  alveoli.  The 

JorVet J1550 ICU Unit

 can  produce  0.5-4  micron  atomized particles  of 

medicine.  Meanwhile,  intelligent  control  quantity  of  atomization  is  provided  for  your selection, 
and  the  maximum  atomizing  volume  is  up  to  0.5ml/min.  The  atomization  in  the  ICU  is even, 
and  the  inhalation  effect  of  atomized  medicines  is  obvious.  The  medical  atomizer  is 
characterized by low noise, which complies with pet ICU noise standard.

An increase in carbon dioxide concentration is accompanied by a decrease in oxygen concentration. Being 

anoxic under low oxygen and high concentration of carbon dioxide for a long time will cause pulmonary 

edema, cerebral edema, metabolic acidosis, electrolyte imbalance, shock, hypoxic encephalopathy, etc. 

When the carbon dioxide concentration reaches 1000PPM above, it will cause dizziness, drowsiness and 

reduced resistance to pets; when the carbon dioxide concentration reaches 2000-5000PPM, it will cause 

mild nausea, poor breathing, rapid heartbeat and electrolyte imbalance to pets, and seriously affect the 

health of pets and their postoperative rehabilitation; and when the carbon dioxide concentration is over 

5000PPM, it will cause severe hypoxia, coma and even death.

08

09

The negative ion generator boosts low voltage to negative high voltage DC through the voltage 

booster circuit. DC high voltage from the tip of carbon brush is used to produce high corona and 

lots of high-speed electrons are released. Since electronics cannot exist in the air for a long time 

(the life of existing electrons is n S level), they will be captured by oxygen molecules (O

2

) in the air 

immediately, and then negative ions are formed; the working principle of which is the same as 

natural phenomenon (negative ions are produced when there is thunder and lightning).

Test equipment: KEC-990 air ion concentration tester, HG3830 high voltage test bench

In case of no electricity, no abnormalities occur after 

being placed for 72 hours at ambient temperature of 

+25°C and relative humidity of 95%.

In case of no electricity, no abnormalities occur after 

being placed for 72 hours at ambient temperature of 

+70°C
In case of no electricity, no abnormalities occur after 

being placed for 72 hours at ambient temperature 

of-20°C.
Starting at 100cm (39.37”) from the ground, free fall onto 

the board, it will still function properly.

Drop test

II Principle of Operation

Low-temperature

characteristics

High-temperature

characteristics

Humidity resistance

Storage temperature

Operating humidity range

Operating temperature range

-20°C~+70°C

  40%~85%  

-10°C~+40°C

Rated power
Input current

1W

80mA

Содержание J1550

Страница 1: ...J1550 JorVet ICU User Manual Professional Veterinary Equipment Supplier Jorgensen Laboratories Inc 1450 N Van Buren Ave Loveland CO 80538 800 525 5614 info jorvet com www jorvet com...

Страница 2: ...s moderately sized piece of pet medical equipment will easily fit into most veterinarians practices and pet hospitals Its characteristics and compact structural design function perfectly to serve its...

Страница 3: ...tank has water half of the maximum level 1 Provides bacteria free and thermostatic incubation cocoon for young pets 2 Allows for body temperature recovery fluid infusion atomization treatment incubati...

Страница 4: ...er on the left side of ICU Insert the power plug into the socket on the ICU 2 Screw off the cup lid and nozzle pour medicine liquid into the nebulizer cup 3 Screw on the cup lid and nozzle and put the...

Страница 5: ...5KVd c 3 5KV DC 0 5KV DC Anion concentration At DC12V 6 106 PCS cm3 10 Insulation resistance Power line external box 20M 500V DC Dielectric streangth Power line external box AC 1800V 60HZ 5mA 3S No b...

Страница 6: ...than 2 microns medicines can enter into the finest bronchus and alveoli The JorVet J1550 ICU Unit can produce 0 5 4 micron atomized particles of medicine Meanwhile intelligent control quantity of atom...

Страница 7: ...nd cannot exceed the set value for three minutes It will trigger the alarm system and start the intelligent ventilation system at the same time being ventilated with the outside air and thus improve t...

Страница 8: ...umidifying If an additionally purchased cooler is connected start the cooling function for dehumidifying Indicator lamp control The humidity indicator lamp is always on at the time of humidifying The...

Страница 9: ...on and Steriliza on Control Part 9 Illumina on Intensity Control 10 O2 concentra on monitoring Press illumination adjustment key to adjust ten grades of illumination intensity See fig 7 9 1 The highe...

Страница 10: ...he humidifier For separate cleaning of the humidifier it is not necessary to remove control racks See the chapter of separate cleaning of the humidifier above If the humidifier is definitely damaged o...

Страница 11: ...r Atomizing time and volume depend on concentration of atomizing liquid Repeat the atomization operation procedure if not completely atomized once The humidity is not increased after raising the set p...

Страница 12: ...icitly expressed quality conditions Advance replacement warranty service Your warranty service may involve advance replacement warranty service If the hardware is found to be defective after diagnosis...

Отзывы: