Adjusting the heat
NOTICE!
When the kettle is heating, pressure is built up inside the jacket. This pressure can be observed
at the pressure gauge at the rear of the kettle.
Automatic water level control in steam generator
Water level in the steam generator is monitored by the kettle control system. Water will be added auto-
matically if necessary to maintain the correct level.
Manual draining of condensate
Steam-heated kettles only
Under normal operating conditions, condensate is bled off automatically.
Under certain conditions or as a result of incorrect installation, condensate can build up in the bottom of
the kettle.
This causes a loud noise when steam is passed through the condensat.
In such instances, the condensate can be drained through a valve at the bottom of the kettle jacket.
Fig. 0-12 Valve for condensate out
CAUTION!
Beware of hot steam/water when valve is opened!
Step
Action
1
Switch off the heating and position the kettle vertically.
2
Wait until pressure in the steam chamber reaches 0 bar.