ENGLISH
Menu 06 SET BUZZER
Use keys 1 and 2 to mute the buzzer each time the
remote control buttons are pressed, then press key 7
to confirm and move to the next page. The acoustic
warning signal on the buzzer remains enabled for alarm
signals.
Menu 07 P1 TO LOAD
Press Key
1
to confirm pellet load start.
When finished, the message DONE will be displayed
to confirm correct data entry. Next, the level page
automatically returns to the Menu Page.
MENU 6 - SET DISPLAY
MENU 7 - LOAD PELLET
When finished loading, message CLEAN BASKET
appears on the main screen to remind the user to clean
the brazier before re-igniting the stove. Press Key
3
to cancel the message and return to the main screen
where message OFF is displayed.
Maximum load time is 90 seconds. This operation can
be interrupted by pressing Key
3
.
The pellet loader must be used when the auger is empty, after a NO PELLETS alarm, or after
maintenance or cleaning of the container.
After completing the Load Pellet sequence in Menu 7, the firebox must be emptied, i.e. the stove must be started
up with a clean firebox.
THE BRAZIER MUST BE FULLY EMPTY EACH TIME THE STOVE IS TURNED ON.
NEVER empty the cleaning pellets from the firebox into the pellet tank.