Alarm code

Alarm test

Alarm cause

Main solution

AL06

NO
PELLET

• 

The temperature falls below the OPERATING 

THRESHOLD setting whilst the stove is running.

• 

Check that the level of PELLETS inside the 

hopper is sufficient

• 

Check the PELLET load times are set 

correctly

• 

Check the OPERATING THRESHOLD 

setting

• 

It may be necessary to load the pellets 

again from Menu 07 before restarting 

the stove. The complete emptying of the 

hopper usually involves the emptying 

of the load auger too; this will lead to a 

start-up with insufficient pellets and trigger 

a NO LIGHTIN- alarm. After completing 

the Load Pellet sequence in Menu 7, the 

firebox  must  be  emptied,  i.e.  the  stove 

must be started up with a clean firebox.

AL07

SAFETY
THERMAL

• 

Tripped thermal safety switch.

• 

Check that the exchange fan is working 

properly

• 

Check to see if the stove is dirty, and clean 

it if necessary

• 

Check the value of the load PELLET 

settings

• 

Check that the safety thermostat and 

relative electrical connections are all intact

AL08

FAILURE
DEPRESS

• 

Tripped safety depressimeter.

• 

Check to see if the combustion product 

exhaust duct is blocked.

• 

Check the component is intact and the 

relative electrical connections correspond 

to the electrical wiring layout

• 

The silicon pipe is not connected to 

connector H.

AL09

DRAFT
MIN

•  The comburent air flow is not within the set range. 

• 

Check that the comburent air inlet is open 

and not partially clogged  .

• 

Check that the chimney pot or the entire 

flue are not dirty and this will reduce the 

fume flow considerably.

• 

Check the heat exchanger and Fire 

Flector deflector are clean (top part of the 

combustion chamber).

• 

Check that the stove combustion chamber 

door is firmly closed.

• 

Make sure that the holes of the pellet 

burning pot are not clogged.

AL11

TRIAC
AUGER

• 

The pellet loader gear motor is continuously enabled.

• 

After the stove is switched off, wait for 

its complete cooling, then turn it on 

again; it may be necessary to replace the 

motherboard or the gear motor. 

AL12

ENCODER
AUGER

• 

The control unit does not detect the correct number of 

revolutions of the gear motor.

•  Contact  the  specialised  Technical 

Service Center.

AL13

FLAME
ANOMAL-

• 

During the stabilisation phase (Flame present) the 

fumes temperature does not exceed the Pr18 FLAME 

DELTA

• 

Check the pellet load and fume exhaust 

fan values, they may be incorrect and not 

keep the flame burning after start up.

AL14

SAFETY 
PELLET

• 

Tripped pellet safety probe, if installed.

• 

Check the pellet load values, they may be 

excessive and cause overheating inside 

the stove cladding.

• 

Check the heat exchange fan is working 

properly, otherwise it can cause 

overheating inside the stove cladding.

• 

Check that the installation room is well 

ventilated.

• 

Check that the slots on the back of the 

stove are clean to allow input of cooling air.

Содержание Radio Control

Страница 1: ...SM095 EN REV05 2016_04 RADIOCONTROL USER MANUAL To be kept by the purchaser Remote radio control for air heating products...

Страница 2: ...uct Please carefully read and keep this sheet before using the equipment The manual provides information and suggestions necessary for correct product use Knowing and observing these instructions will...

Страница 3: ...5 BATTERY INSTALLATION AND REPLACEMENT 8 02 6 RADIO CHANNEL SETTINGS 9 02 7 KEYBOARD LOCK 9 02 8 DISPLAY BACKLIGHT 10 CHAP 03 OPERATING MODE 11 03 1 APPLIANCE OPERATIONS 11 03 2 REMOTE CONTROL USE AS...

Страница 4: ...d by Jolly Mec Caminetti S p A The descriptions and illustrations provided in the following publication are not binding Jolly Mec Caminetti S p A reserves the right to make any modifications that may...

Страница 5: ...g value 3 ON OFF ESC RESET OFF Turns on WORK Turns off ALARM Resets the alarm MENU Returns to the previous level 4 Temperature selection OFF Lets you set Room temperature WORK Lets you set Room temper...

Страница 6: ...e auger gear motor and electrical resistance are running Room probe request Day chronothermostat program Auger gear motor Chronothermostat Week chronothermostat program Fume fan Electrical resistance...

Страница 7: ...next to the keys indicate the set output level Led On Output level 1 1 1 and 2 3 2 5 Remote control connection to the console Radio wave transmission between the radio control and control unit by natu...

Страница 8: ...check whether the batteries are charged Otherwise replace them with new ones of the same type To replace the batteries remove the cover on the back of the radio control insert the batteries in the spe...

Страница 9: ...ssociated channel Without turning device power off simultaneously press keys 1 and 2 and set the various channels from 0 to 7 in sequence until the correct channel is found If the channel set in the e...

Страница 10: ...isplayed Press Keys 1 or 2 to adjust backlight off delay time in seconds After setting the required value press Key 3 to confirm and exit settings If DELAY OFF 0 factory settings are not changed the s...

Страница 11: ...ng mode i e at the heat output level until the set ambient temperature is exceeded by 0 5 C a condition required to trigger the ECO function To restart the heating mode the ambient temperature must de...

Страница 12: ...e operations in work mode meaning until the temperature read by the room probe reaches the set value p0 The number indicated next to the letter P indicates the output level at which the device is runn...

Страница 13: ...selecting the required output level press Key 3 to return to the main page To change the required temperatures press Key 4 on the main page to immediately open the relevant section The set value can b...

Страница 14: ...he remote control as a room probe 5 SET STAND BY STAND BY mode lets you turn off the appliance when room request according to the set configuration is met In STAND BY display message the appliance is...

Страница 15: ...ys 1 and 2 and press Key 7 to set the displayed value and move to the next page Menu 01 DAY CLOCK To select the current day use Keys 1 and 2 and press Key 7 to set the displayed value and move to the...

Страница 16: ...2 to adjust the delay time When the appliance is OFF set DELAY TURN ON for deferred appliance start or with the appliance in WORK set DELAY TURN OFF to program shutdown The function is disabled when...

Страница 17: ...Y Use Keys 1 and 2 to set the end time for the first operating time range permitted by the function and press Key 7 to confirm the selection and move to the next page M2 3 005 TEM ROOM PROG 1 Use Keys...

Страница 18: ...in the first time range and then press Key 7 to confirm the selection and move to the next page M2 4 005 MONDAY PROG 1 Use Keys 1 and 2 to select to enable or disable the program created for the displ...

Страница 19: ...press Key 7 to confirm the selection and move to the next page M02 05 005 TEM ROOM PROG 1 Use Keys 1 and 2 to set the room temperature value to be reached in the first time range and then press Key 7...

Страница 20: ...nished the message DONE will be displayed to confirm correct data entry Next the level page automatically returns to the Menu Page MENU 4 SET PROBE MENU 5 SET STAND BY Menu 05 DELTAOFF STAND BY Use Ke...

Страница 21: ...EAN BASKET appears on the main screen to remind the user to clean the brazier before re igniting the stove Press Key 3 to cancel the message and return to the main screen where message OFF is displaye...

Страница 22: ...e settings Information for the assistance technician are provided from page 4 to page 8 Press Button 5 to go to page 8 Press Button 3 to go back a level MENU 8 STATE STOVE MENU 09 TECHNIC SETTINGS The...

Страница 23: ...1 and 2 to adjust fume exhaust speed between 09 and 09 corresponding to 3 each unit and press Key 7 to confirm and move to the next page MENU 11 READ MEMORY Menu 11 TOTAL HOURS Total operating hours a...

Страница 24: ...product serial number is displayed in this page Menu 11 BATCH The product lot number is displayed in this page Press button 5 to move from one alarm page to the other four Menu 11 FLOW EXCLUDED The n...

Страница 25: ...nuity interruptions AL03 HOT EXHAUST The fumes temperature is over 270 C Check the position of the fumes probe Check to see if the air exchange fan is running properly Check to see if the stove is dir...

Страница 26: ...The comburent air flow is not within the set range Check that the comburent air inlet is open and not partially clogged Check that the chimney pot or the entire flue are not dirty and this will reduc...

Страница 27: ...back of the stove are clean to allow input of cooling air AL16 SERVICE 24H The device continuously remained on for over 24 hours Thoroughly clean all the parts firebox ash pan exchanger glass firebox...

Страница 28: ...ethods CEI EN 61000 3 2 Electromagnetic compatibility Part 3 Section 2 Part 4 Sections 2 4 5 6 8 9 11 29 Some device specifications are listed below Description Value UM Operating room temperature 0 6...

Страница 29: ...ENGLISH NOTES 29...

Страница 30: ...30...

Страница 31: ...ENGLISH 31...

Страница 32: ...SM095 EN REV05 2016_04 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: