MAIN STATUS MESSAGE MEANINGS

During normal operations, the radio control screen displays the time, room temperature, output level and a message that indicates device 

status when the message is displayed. An illustration of the main display screen appears below. 

Pricipal messages that can appear on the remote control and their meanings are summarised in the following table:

MESS-

TEXT

Description

OFF

Message displayed when the appliance is off. It can be switched on in manual mode, using a 

GPRS system or chronothermostat settings.

SMOKES
INITIAL

Message displayed during the initial ventilation phase before ignition.

ON

Message displayed during the phases which involve pre-heating of the spark plug and pre-

loading of the pellets.

WAIT
FLAME

Message is displayed during the stand-by time before the pellets are ignited. The fumes 

temperature must reach a set value for the device to be considered ON.

fLAME
ON

Message displayed when the device is on. This message remains on the screen for a short 

period of time while the flame stabilises and pellet ignition in the brazier is completed.

WORK

Message displayed during device operations in work mode, meaning until the temperature read by 

the room probe reaches the set value..

p0

The number indicated next to the letter P indicates the output level at which the device is running

BASKET
CLEANING

Message displayed during the clean brazier automatic cycle that is run at regular intervals while 

the stove is running. A forced ventilation cycle of the fumes extractor removes any excess 

unburned materials from the brazier.

final
CLEANING

Message displayed during the shutdown phase.

eco
modulaT-

Message displayed when the room temperature value is reached. The appliance automatically 

switches to economy mode.

OK
STBY

The previous screen is alternated when, after a period of running in ECONOMY mode, the 

device enters STAND-BY and shutdown conditions are met.

OFF
WAITING-

Message displayed when, during the start phase, the switch off button is pressed. Device 

shutdown during the switch-on phase is not permitted.  Therefore, the command is saved and 

will be run at the end of the stabilisation phase.

COOLING
WAITING-

Message displayed during the shutdown phase for STAND-BY mode

WAIT
RESTART

Message displayed when, during the shutdown phase, the switch on button is pressed. Device 

start during the shutdown phase is not permitted.  Therefore, the command is saved and run 

when the fume temperature drops under 80°C.

Содержание Radio Control

Страница 1: ...SM095 EN REV05 2016_04 RADIOCONTROL USER MANUAL To be kept by the purchaser Remote radio control for air heating products...

Страница 2: ...uct Please carefully read and keep this sheet before using the equipment The manual provides information and suggestions necessary for correct product use Knowing and observing these instructions will...

Страница 3: ...5 BATTERY INSTALLATION AND REPLACEMENT 8 02 6 RADIO CHANNEL SETTINGS 9 02 7 KEYBOARD LOCK 9 02 8 DISPLAY BACKLIGHT 10 CHAP 03 OPERATING MODE 11 03 1 APPLIANCE OPERATIONS 11 03 2 REMOTE CONTROL USE AS...

Страница 4: ...d by Jolly Mec Caminetti S p A The descriptions and illustrations provided in the following publication are not binding Jolly Mec Caminetti S p A reserves the right to make any modifications that may...

Страница 5: ...g value 3 ON OFF ESC RESET OFF Turns on WORK Turns off ALARM Resets the alarm MENU Returns to the previous level 4 Temperature selection OFF Lets you set Room temperature WORK Lets you set Room temper...

Страница 6: ...e auger gear motor and electrical resistance are running Room probe request Day chronothermostat program Auger gear motor Chronothermostat Week chronothermostat program Fume fan Electrical resistance...

Страница 7: ...next to the keys indicate the set output level Led On Output level 1 1 1 and 2 3 2 5 Remote control connection to the console Radio wave transmission between the radio control and control unit by natu...

Страница 8: ...check whether the batteries are charged Otherwise replace them with new ones of the same type To replace the batteries remove the cover on the back of the radio control insert the batteries in the spe...

Страница 9: ...ssociated channel Without turning device power off simultaneously press keys 1 and 2 and set the various channels from 0 to 7 in sequence until the correct channel is found If the channel set in the e...

Страница 10: ...isplayed Press Keys 1 or 2 to adjust backlight off delay time in seconds After setting the required value press Key 3 to confirm and exit settings If DELAY OFF 0 factory settings are not changed the s...

Страница 11: ...ng mode i e at the heat output level until the set ambient temperature is exceeded by 0 5 C a condition required to trigger the ECO function To restart the heating mode the ambient temperature must de...

Страница 12: ...e operations in work mode meaning until the temperature read by the room probe reaches the set value p0 The number indicated next to the letter P indicates the output level at which the device is runn...

Страница 13: ...selecting the required output level press Key 3 to return to the main page To change the required temperatures press Key 4 on the main page to immediately open the relevant section The set value can b...

Страница 14: ...he remote control as a room probe 5 SET STAND BY STAND BY mode lets you turn off the appliance when room request according to the set configuration is met In STAND BY display message the appliance is...

Страница 15: ...ys 1 and 2 and press Key 7 to set the displayed value and move to the next page Menu 01 DAY CLOCK To select the current day use Keys 1 and 2 and press Key 7 to set the displayed value and move to the...

Страница 16: ...2 to adjust the delay time When the appliance is OFF set DELAY TURN ON for deferred appliance start or with the appliance in WORK set DELAY TURN OFF to program shutdown The function is disabled when...

Страница 17: ...Y Use Keys 1 and 2 to set the end time for the first operating time range permitted by the function and press Key 7 to confirm the selection and move to the next page M2 3 005 TEM ROOM PROG 1 Use Keys...

Страница 18: ...in the first time range and then press Key 7 to confirm the selection and move to the next page M2 4 005 MONDAY PROG 1 Use Keys 1 and 2 to select to enable or disable the program created for the displ...

Страница 19: ...press Key 7 to confirm the selection and move to the next page M02 05 005 TEM ROOM PROG 1 Use Keys 1 and 2 to set the room temperature value to be reached in the first time range and then press Key 7...

Страница 20: ...nished the message DONE will be displayed to confirm correct data entry Next the level page automatically returns to the Menu Page MENU 4 SET PROBE MENU 5 SET STAND BY Menu 05 DELTAOFF STAND BY Use Ke...

Страница 21: ...EAN BASKET appears on the main screen to remind the user to clean the brazier before re igniting the stove Press Key 3 to cancel the message and return to the main screen where message OFF is displaye...

Страница 22: ...e settings Information for the assistance technician are provided from page 4 to page 8 Press Button 5 to go to page 8 Press Button 3 to go back a level MENU 8 STATE STOVE MENU 09 TECHNIC SETTINGS The...

Страница 23: ...1 and 2 to adjust fume exhaust speed between 09 and 09 corresponding to 3 each unit and press Key 7 to confirm and move to the next page MENU 11 READ MEMORY Menu 11 TOTAL HOURS Total operating hours a...

Страница 24: ...product serial number is displayed in this page Menu 11 BATCH The product lot number is displayed in this page Press button 5 to move from one alarm page to the other four Menu 11 FLOW EXCLUDED The n...

Страница 25: ...nuity interruptions AL03 HOT EXHAUST The fumes temperature is over 270 C Check the position of the fumes probe Check to see if the air exchange fan is running properly Check to see if the stove is dir...

Страница 26: ...The comburent air flow is not within the set range Check that the comburent air inlet is open and not partially clogged Check that the chimney pot or the entire flue are not dirty and this will reduc...

Страница 27: ...back of the stove are clean to allow input of cooling air AL16 SERVICE 24H The device continuously remained on for over 24 hours Thoroughly clean all the parts firebox ash pan exchanger glass firebox...

Страница 28: ...ethods CEI EN 61000 3 2 Electromagnetic compatibility Part 3 Section 2 Part 4 Sections 2 4 5 6 8 9 11 29 Some device specifications are listed below Description Value UM Operating room temperature 0 6...

Страница 29: ...ENGLISH NOTES 29...

Страница 30: ...30...

Страница 31: ...ENGLISH 31...

Страница 32: ...SM095 EN REV05 2016_04 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: