12
03.3
MAIN STATUS MESSAGE MEANINGS
During normal operations, the radio control screen displays the time, room temperature, output level and a message that indicates device
status when the message is displayed. An illustration of the main display screen appears below.
Pricipal messages that can appear on the remote control and their meanings are summarised in the following table:
MESS-
TEXT
Description
OFF
Message displayed when the appliance is off. It can be switched on in manual mode, using a
GPRS system or chronothermostat settings.
SMOKES
INITIAL
Message displayed during the initial ventilation phase before ignition.
ON
Message displayed during the phases which involve pre-heating of the spark plug and pre-
loading of the pellets.
WAIT
FLAME
Message is displayed during the stand-by time before the pellets are ignited. The fumes
temperature must reach a set value for the device to be considered ON.
fLAME
ON
Message displayed when the device is on. This message remains on the screen for a short
period of time while the flame stabilises and pellet ignition in the brazier is completed.
WORK
Message displayed during device operations in work mode, meaning until the temperature read by
the room probe reaches the set value..
p0
The number indicated next to the letter P indicates the output level at which the device is running
BASKET
CLEANING
Message displayed during the clean brazier automatic cycle that is run at regular intervals while
the stove is running. A forced ventilation cycle of the fumes extractor removes any excess
unburned materials from the brazier.
final
CLEANING
Message displayed during the shutdown phase.
eco
modulaT-
Message displayed when the room temperature value is reached. The appliance automatically
switches to economy mode.
OK
STBY
The previous screen is alternated when, after a period of running in ECONOMY mode, the
device enters STAND-BY and shutdown conditions are met.
OFF
WAITING-
Message displayed when, during the start phase, the switch off button is pressed. Device
shutdown during the switch-on phase is not permitted. Therefore, the command is saved and
will be run at the end of the stabilisation phase.
COOLING
WAITING-
Message displayed during the shutdown phase for STAND-BY mode
WAIT
RESTART
Message displayed when, during the shutdown phase, the switch on button is pressed. Device
start during the shutdown phase is not permitted. Therefore, the command is saved and run
when the fume temperature drops under 80°C.