26
CHAP.08 USE AND MAINTENANCE FOR THE USER
08.1
APPLIANCE START AND USE
Before switching on the device for the first time it is necessary to
remove from inside all documentation and accessories that come
together in the supply and read the instructions for use, especially
the parts about the recommended fuels and other most relevant
issues.
The commissioning service has to be done by a specialised
Technical Service Center.
Before operating the stove, put the comburent air regulation lever to
position 1 (
F
ig
. 1
).
Small pieces of wood
(for models QL10 and QL15 maximum LxHxP
30x4x4 cm and for models TL10 and TL15 maximum LxHxP 25x4x4
cm)
must be used to light the fire, stacking them on the fireplace grate
(as seen in
F
ig
. 3
).
Standard fire-lighters can be used to make the starting phase easier
(never use ethyl alcohol or other inflammable liquids). The door can
be left slightly open during the fire starting phase.
Once finished the first load, you can put in wood in the quantities as
given at the end of the paragraph, in the centre of the fire floor in
parallel with the back wall of the stove (
F
ig
. 4
)
.
To maximise stove
performance and avoid the dispersion of fumes from combustion, the
stove must be filled in when the flame extinguishes. Before placing
the wood on the fire base, it is recommended to break and evenly
distribute the cinders using a cinder tray.
For the following uses, follow the same procedure given above after
first cleaning the stove and after letting excess ashes on the fire floor
fall into the drawer below and emptying it thereafter (considering that
a layer of ash can contribute to start the stove in an easier way).
The stove potentiality and the duration of the wood load are governed
by the quantity of wood filled in.
The appliance’s combustion is intermittent and it is obtained by
positioning a new load of wood on the fireplace at the end of
combustion of the previous charge.
To achieve the declared nominal heat output, adjust the unit as
follows:
- QL10 model: charge 2 blocks of approx. 0,8 kg each with the
primary air closed (
F
ig
. 2
) (Max length 30 cm and width approx.
8-10 cm per side. Use of pieces of chopped wood is recommended)
;
- TL10 model: charge 2 blocks of approx. 0,8 kg each with the
primary air closed (
F
ig
. 2
) (Max length 25 cm and width approx.
8-10 cm per side. Use of pieces of chopped wood is recommended)
;
- QL15 model: charge 2 blocks of approx. 0,8 kg each with the
primary air closed (
F
ig
. 2
) (Max length 30 cm and width approx.
8-10 cm per side. Use of pieces of chopped wood is recommended)
;
- TL15 model: charge 2 blocks of approx. 0,8 kg each with the
primary air closed (
F
ig
. 2
) (Max length 25 cm and width approx.
8-10 cm per side. Use of pieces of chopped wood is recommended)
.
The hearth must always be closed, except when the wood is added, to avoid the leakage of smoke. Always open
and close the door gently, and make sure the handle is locked firmly in place.
To prevent damage to the Fireflector (not included in the warranty) always avoid overloading the fireplace or throwing pieces
of wood into the combustion chamber.
WARNING
F
ig
. 1
F
ig
. 2
F
ig
. 3
F
ig
. 4
OPEN
CLOSE
Содержание QL10