background image

20

 

07.3 

INSTALLATION ROOM VENTILATION

According to reference regulation UNI10683, 4 Pa depression must be verified between the installation room interior and exterior. 

Prepare adequate ventilation openings in the room where the product is installed to permit at least 50 m³/h clean comburent air flow not 

taken from polluted rooms. The ventilation openings, if fitted with insect-proof mesh, must be easily removable and undergo periodic 

cleaning to ensure clear air flow passage.

If the comburent air inlet is directly connected to the stove, it may be necessary to make adjustments to the control unit, especially during

the start-up phase, as the temperature and humidity of outdoor air not only varies during the period of use of the product, but also come

into direct contact with the pellets and the ignition element, generating different fuel burning times.

Jolly Mec allows the ducting system at the input of the combustion air within and not over the following limits: the length can’t be longer

that 1000 mm, the diameter has to have at least the same section of the stove/boiler connection, it is possible only one 90° change of

direction, the center-to-center distance of the combustion air input pipe can be ± 300 mm.

 As per the fuel product exhaust system, air vents are also extremely important and must be given the appropriate

consideration and respect.

The installer is directly liable for all electrical system parts, generation hook-up to the system, ventilation and the fume 

exhaust system and MUST, at the end of installation work, issue a declaration of conformity as per Ministerial Decree 37/08.
On the other hand, the purchaser MUST assign all work to a qualified professional technician.
The device must be installed and used in accordance with all local and national laws and EC Regulations.

WARNING

In the event of a black-out, suitable sizing of the fume exhaust system guarantees sufficient draught to exhaust the fumes generated by 

combustion without the use of the electric exhaust fan.
If the performance of the fume exhaust system is not excellent, it is possible to adjust the operating settings of the stove to overcome 

draught defects by a maximum of 15% of the fume exhaust device; this adjustment is however the exclusive competence of the 

specialised Technical Service Center.
One airtight reading point is recommended on the flue to check emissions after installation and measure draught.
Supporting the weight of the flue with the appliance union is strictly forbidden. Use specific stands or independent supports for this 

purpose.
To install other combustion devices in the same room where the pellet appliance is installed, refer to UNI 10683 and UNI 7129 installation 

regulations.
The minimum flue height must be over 3,0 m.
Blocking of wall exhaust terminals at any height and any distance from openings, doors and/or windows is not permitted and a very 

important rule to follow.
Installation of external fireplaces must be performed using insulated double-walled pipes, to prevent the formation of condensate; it must 

also be possible to inspect the base of the fireplace for routine maintenance which must be done at least once a year.
A windproof chimney cap must be installed; in the presence of adverse weather conditions, especially high winds, this accessory allows 

the stove flue draught system to operate much easier.
A minimum flue draught between 10 and 14 Pa must be guaranteed. This value must be measured using specific and controlled 

instruments each time the appliance and flue undergo maintenance. 

With strong winds and the chimney cap installed in the reflux 

area (see 

F

ig

.2

, zone bordered by the dotted line A for roofs with 

ß>10° slant) of the roof or without complying with the distances 

foreseen by UNI 10683 situations may arise where the stove 

does not work which will trigger the no depression alarm.
It is not possible to make corrections or reset the stove operating 

values to override the alarm.

 It is only recommended to connect the comburent air ducting system to the stove if absolutely necessary. Very

cold air and humidity may cause difficulties during the stove ignition phase.

NOTE

 

It is not allowed to install coaxial systems for the smoke output.

WARNING

.

130 cm

.

50 cm

ß>10°

A

90°

F

ig

. 2

Содержание I-DEA2 QUADRA

Страница 1: ...SM121 EN REV01 2017_08 INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Pellet operated air heating stove I DEA2 QUADRA I Dea2 Quadra ...

Страница 2: ...ly read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing these instructions will allow you to fully and safely enjoy the potential your equipment can offer you ...

Страница 3: ... 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 COMPONENTS 16 06 4 DIMENSIONS 17 CHAP 07 POSITIONING AND CONNECTIONS FOR THE INSTALLER 18 07 1 SETTING UP OF EXTERNAL AIR INTAKES AND ELECTRIC CURRENT 18 07 2 FLUE OR FUME EXHAUST SYSTEM 19 07 3 INSTALLATION ROOM VENTILATION 20 07 4 ASSEMBLY S...

Страница 4: ...opriate This manual cannot be given to third parties for perusal without the written permission of Jolly Mec Caminetti S p A The technical directions for installation contained in this manual should be considered as basic requirements Regulations in some countries may be more restrictive in this instance comply fully with the regulations prevailing in the country of installation all laws and local...

Страница 5: ...old electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted with gas diesel or solid fuel burners and electrical connections EN 62233 Measurement methods for electromagnetic fields of electrical appliances for home use and similar goods regarding human exposure EN 5...

Страница 6: ... right to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER LIABILITY AND WARRANTY CONDITIONS Upon the delivery of this manual Jolly Mec S p A cannot be held liable whether civil or criminal for accidents due to partial or total non compliance with the specifications herein contained The manufacturer is espec...

Страница 7: ... sensory or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of the deriving dangers Children are not allowed to play with the device Cleaning and maintenance are meant to be performed by the user and not by unsupervised children The settings and programming of ...

Страница 8: ...nce with the laws and standards in force in the State Region or Area in which the machine is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly prohibited The system installer MUST issue a Declaration of compliance for the work performed after commissioning the system in accordance with the laws in force related to system safety standards T...

Страница 9: ...ours of operation shall be reset at the end of the Technical intervention and indicated on the Servicing Report 02 4 EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL Every operator performing maintenance on the machine must wear safety garments and personal protective equipment 1 Protection headphones 2 Gloves hand protections 3 Respiratory mask 4 Face mask or goggles 5 Accident prevention boots ...

Страница 10: ...e 03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manual and must wear work gloves and safety footwear For safety reasons unauthorised persons must not be in the area while the product is being moved The product must be moved only with a trolley or pall...

Страница 11: ...our and DO NOT disperse the packaging into the environment but take it to waste disposal centres for recycling All packaging can be recycled as it consists of wood polyethylene film polystyrene and cardboard WARNING 04 2 DISPOSAL OF THE MACHINE The stove is mainly composed of ferrous materials but it may also contain piping insulating materials electrical parts etc refractory materials When you no...

Страница 12: ... product from the IR remote control Timer controlled thermostat used to set the start up and switch off times Ambient temperature setting and viewing of the current ambient temperature on the display Output levels possibility to adjust the heat output to five different levels and to set the Silent mode Operating mode displays real time product operating modes They are also fitted with PELLET hoppe...

Страница 13: ... de CO Emisión de CO Tensione Frequenza nominale Rated voltage frequency Spannung Nennfrequenz Tension Fréquence nominale Tensión Frecuencia nominal Temperatura dei fumi Flue gas temperature Abgastemperatur Température des fumées Temperatura de los humos Leggere e seguire le istruzioni di funzionamento Read and follow the operating instructions Lesen und befolgen Sie die Betriebsanleitungen Lire e...

Страница 14: ...Rated voltage 230 V Rated frequency 50 Hz Electrical absorption Switching on nominal power reduced power stand by 355 65 38 2 W Device mass 125 Kg Standard hopper capacity 25 Kg Flue draught 10 Pa Fume exhaust diam 80 mm Average fume Temperature at nominal output 174 2 C Average fume Temperature at reduced output 103 2 C CO 13 O2 at nominal output 164 mg m3 CO 13 O2 at reduced output 574 mg m3 CO2...

Страница 15: ...ot use pellets that are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction depending on the quality of the pellets used and or by the dosage of the quantity will be covered by the warranty PELLET QUALITY IS VERY IMPORTANT PLEASE READ THIS SECTION CAREFULLY WARNING CERTIFIED PELL...

Страница 16: ...witch 7 Electronic control unit 8 Pellet loading auger gear motor 9 Pellet loading auger 10 IR receiver 11 Combustion chamber grid 12 Firebox 13 Ash drawer 14 Combustion chamber door 15 Emergency console 16 Safety thermostat with manual reset 17 Electrical socket with fuses and Main electric switch 18 Room temperature probe 19 Heating fan 20 Combustion and fume exhaust fan Ø80 mm 21 Comburent air ...

Страница 17: ...17 ENGLISH 06 4 DIMENSIONS All measurements are in mm I Dea2 Quadra A 846 B 1153 C 276 I Dea2 Quadra C A B ...

Страница 18: ...haust pipes and flue can be easily accessed for maintenance Fig 1 illustrates minimum distances that must be observed all measures must be in mm The lateral distance from the adjacent wall according to installation is to be maintained on both sides 1 Electrical socket 2 External air inlet see chap 07 4 3 Comburent air intake 4 Rear panel 5 Side panel As indicated in the national reference standard...

Страница 19: ...ere are deviations or curves for easier quicker and safer installation we recommend using double walled stainless steel pipes The use of pipes in fibre cement for connecting the equipment to the flue is forbidden Exhaust pipes must not run through rooms where the installation of combustion equipment is forbidden The union must be connected to the flue in such a way as to ensure they remain airtigh...

Страница 20: ...ce of the fume exhaust system is not excellent it is possible to adjust the operating settings of the stove to overcome draught defects by a maximum of 15 of the fume exhaust device this adjustment is however the exclusive competence of the specialised Technical Service Center One airtight reading point is recommended on the flue to check emissions after installation and measure draught Supporting...

Страница 21: ...tion room in this case a ventilation opening needs to be designed in compliance with the specifications in paragraph 07 3 4 All models may be connected to the fume pipes with rear fume outlet Fig 1 or with upper fume outlet Fig 2 see AD132 For the construction of fume pipes please comply with the specifications in CHAP 07 2 Assembly of the humidifier optional 1 Open the door using the handle suppl...

Страница 22: ...vent that the control unit does not switch on even after turning the switch to I ONE check that the fuses are intact 1 Control unit 2 Earth 3 Power socket with cord included 4 Switch 5 Fuse Ø5X20 F4A 250V IEC 127 II Electrical connections must be carried out by skilled personnel according to the regulations in force 2014 30 UE and 2014 35 UE WARNING JP2 JP8 JP9 JP1 JP3 JP6 BROWN BLUE BLUE BROWN 5 ...

Страница 23: ...RNING BROWN BLUE VIOLET WHITE WHITE PINK WHITE BLUE BLUE BLUE RED BLUE BLUE ORANGE RED WHITE BLACK BLACK RED BLUE JP2 JP8 JP9 JP1 JP3 JP6 2 1 3 4 5 6 7 8 9 10 11 12 13 14 Number Description 1 Control display 2 Electronic card 3 Bipolar switch 4 Electric power cord with schuko socket 5 Smoke fan 6 Electrical heating element 7 Exchange fan Number Description 8 Bulb type safety thermostat 9 Fume pres...

Страница 24: ... harmful gases Where it is impossible to wall up the distribution pipes they can be hidden with a suspended ceiling fake beams or casing The space A between the vents and the wall must be hermetically sealed with silicone to prevent leaking air from blackening it due to heat for instance smudges above radiators To duct air into the other rooms connect the pipe to the stove s rear outlets in order ...

Страница 25: ... efficient combustion All the operations for managing machine functions are handled by the supplied radio remote control see manual SM119 attached 08 2 CONTROL UNIT The motherboard is connected to the display mounted on the stove and manages all its functions Furthermore the main functions of the motherboard can be managed through the IR remote control The electronic control unit features a timer ...

Страница 26: ...operating the fan speed for the hot air depends on the output levels the higher the output level the faster the air will be pumped through the front outlet By setting the chronothermostat it is possible to create time slots for programmed ignitions and shutdowns In case of alarm before each new ignition it is compulsory to empty and clean the combustion pot from any combustion residual and from an...

Страница 27: ...completely cold on average 20 minutes 2 Open the trapdoor on the right 3 Unscrew the thermostat reset button lid on the back of the appliance see Fig 1 positions B 4 Press the button until you hear a CLICK 5 Refit the hood 6 Reset the alarm from the radio remote control by pressing the ON OFF button and waiting for the OFF message 7 Start up again the appliance If the alarm persists contact the sp...

Страница 28: ...ty and creates functional problems for the stove With low quality or non certified pellets the frequency with which the bottom of the hopper needs cleaning to remove sawdust could become more frequent The pellets must be fed into the hopper using a scoop Do not empty the sack directly into the hopper Check for obstructions in the flue and in the external air intake before starting the machine afte...

Страница 29: ...litate and improve device cleaning use an ash vacuum not supplied with the stove but available from retailers and or specialised Technical Service Centers ORDINARY CLEANING THE INSTRUCTIONS BELOW REGARDING THE TIMING AND METHODS USED FOR THE VARIOUS PARTS TO BE CLEANED MUST BE CAREFULLY FOLLOWED 1 Stove door opening To open the stove combustion chamber door use the handle supplied with the product...

Страница 30: ...e the upper part of the burner Fig 5 6 7 8 It is compulsory to clean the firebox thoroughly making sure no holes are clogged Eliminate the wastes on the firebox by overturning them and use a pointed object to remove any scales by hitting the firebox internal walls and shaking it eventually Before replacing the firebox check there is no ash or dirt in the firebox housing Vacuum this area thoroughly...

Страница 31: ...light pressure to lift the pellet hopper cover pulling upwards to release the magnet closure Fig 17 18 Empty the pellet container every 500 1000 Kg of pellet burnt and check that no sawdust has accumulated on the bottom Clean the bottom of the container carefully After a long period of inactivity empty the container and auger completely 5 Fume inspection cleaning Remove the inspection cover under ...

Страница 32: ...mes dirty with black smoke the brazier is probably dirty or the combustion air must be increased Be careful not to use overly aggressive products to avoid ruining the paint Never spray detergents directly onto the parts to be cleaned Fig 21 22 If the stove requires more frequent and deeper cleaning check the flue draught performance and the chimney cap A windproof chimney cap is strongly recommend...

Страница 33: ...ition After inserting the plug into the power socket press the switch O I on pos I 11 Pellet hopper loading Located on the side of the device the hopper is filled through an openable lid The hopper must be filled with pellets using a shove not supplied Fig 33 34 and not poured in directly from the bag 12 Topping up the humidifier Let open the combustion chamber door and lift up the strip of the hu...

Страница 34: ...special focus on horizontal segments Stove fume pass cleaning Cleaning of any deposits in the stove Cleaning of fans Check good ignition resistance operations Check electric electronic system integrity Check safety device thermostat and pressure switch status and efficiency Check the condition of the sealing gaskets paying special attention to the one on the closure of the combustion chamber door ...

Страница 35: ...ice thermostat and pressure switch status and efficiency T Check the condition of the sealing gaskets paying special attention to the one on the closure of the combustion chamber door T Check the condition of the ceramic glass T Check the pellet loading gear motor is working properly T Clean the bottom of the pellet hopper T KEY U routine maintenance by the customer user T extraordinary maintenanc...

Страница 36: ...ically The firebox is dirty preventing incoming air flow Clean it thoroughly and check it is clean each time you start it up The basket is positioned incorrectly The resistance is faulty The pellets burn incorrectly and unburnt elements gather in the basket the glass looks black and is very dirty Low flue draught do not use the fireplace it could be dangerous carefully clean the flue the stove and...