85-03-00954
7 |
P a g e
FV34 FEATURES - QUICK REFERENCE INFORMATION
EXTERNAL DIMENSIONS
: 39-5/8” Wide X 36-1/2” High X 14-1/2” Deep
MINIMUM FRAMING DIMENSIONS
: 40-5/8”” WIDE x 36-3/4” HIGH X 14-5/8” DEEP
GLASS SIZE
: NeoCeram Glass with non-reflective coating. Visible Glass measures 601 in
2
(29-1/2” W x 20-3/8” H).
MANTEL ALLOWANCE
: 8” Deep Mantel at 12” Above Top Convection Opening
VENT SYSTEM ALLOWANCE
: Top Vent Only. 4” exhaust and 6-5/8” combustion air intake coaxial vent pipe required.
18” Vertical Minimum with 6” max horizontal. 40 feet Vertical Maximum. 25’ maximum horizontal run allowed with 5’ min-
imum vertical starter section.
CONTROLS
: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Accent light and Blower oper-
ate on AC Power only. Thermostatic Remote Control Transmitter with Smart Thermostat Mode included.
BLOWER SYSTEM
: 105 CFM High Efficiency Motor Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No
switches, Fan Speed Controls or Light Dimmers are allowed in same circuit.
Accent Light System
: Accent Light System Included and can be turned on or off or dimmed using Remote Control
Transmitter.
BURNER SYSTEM
: Dual 304 Stainless Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS
: Externally controllable Rear Burner air shutter and Internal rotary Front Burner air
shutter.
LOG SET
: 9-piece, Premium Definition Log Set with Extreme glow and realism ember bed.
REFRACTORY PANELS
: Premium Detailed Red Clinker Fiber Brick Panels; Black, Copper, Mocha Enamel Panel Op-
tions.
NATURAL GAS INFORMATION
: Factory equipped for Natural Gas. 5”WC Minimum inlet pressure required. For NG ap-
plications, Front Burner Orifice Size is #49 and the Rear Burner Orifice Size is #44.
LPG INFORMATION
: LP conversion kit #HA-30-00507 is required. 12”WC Minimum inlet pressure required. For the FV34
LPG application, both front are rear burner orifices are to be drill size 3/64”. For higher altitude, adjustment to orifice size
may be necessary.
INITIAL STARTUP ADVICE
PAINT CURING CYCLE RECOMMENDATION
: It is recommended that you run this Fireplace on maximum flame height
and Blowers OFF, for 1 cycle of 2 hours ON and 2 hours OFF, initially, to cure the paint and expel any burn off odors. Ex-
pect small amounts of visible smoke and smell during curing cycle. Open all door and windows during initial cure cycle.
BLOWER BREAK-IN PERIOD
: The integrated blowers in this Insert may exhibit some bearing noise and electrical static
noise during the first few hours of operation. This is normal during the break-in period. The burner flames must be on dur-
ing these cycles.