GENERAL INFORMATION
Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced and highly
efficient system brings in outside air for combustion, has a separate exhaust vent and efficiently heats and re-circulates room air.
The Mendota system maintains high air quality, maximizes efficiency and assures proper operation in today's "air-tight" homes.
SAFETY AND STRUCTURAL CONCERNS:
The FV34 Fireplace must be installed and serviced by a Mendota approved serviceperson. Any adjustments to burner, pilot,
logs or coal bed must be made by a Mendota approved service person. If pilot goes out, always wait five (5) minutes before
attempting to relight pilot.
VENTING REQUIREMENTS:
This Mendota Fireplace can be vented using many available LISTED DIRECT VENT coaxial pipe (4”X 6-5/8”) off the top.
Ap-
proved brands of vent components include DuraVent, Amerivent, ICC, Selkirk and Security vent pipes and venting com-
ponents.
Closely follow venting locations, directions and requirements. Observe the restrictions relating to vent position on
exterior of home. Be sure all vent pipe sections are fully twist-locked and leak-proof. Be sure 1000
º
Silicate Stove Sealant is
used on the inner pipe joints of all Simpson DuraVent pipe components and all adjustable pipe sections.
The Mendota Direct Vent Fireplace may be placed within 16 inches of adjacent sidewalls. The fireplace may be placed directly
on concrete or wood flooring. If the appliance is to be installed on carpeting, vinyl or other combustible material other than wood
flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. An 8”
combustible mantel may be installed at a minimum of 12" above the top of the heat outlet (36-1/16”) up from the floor level of this
fireplace) and no more than 8" out from wall at that height. Non-combustible (marble, brick, stone, etc.) mantels can be installed
at any desired height above the top convection air opening. Combustible Mantels of any depth with a sheet metal protector plate
in its under-side may only be installed
outside
the “NON-COMBUSTILBE ZONE” above the top convection air opening.
Never block off convection air openings or paths. Always use Mendota decorative fronts and Mendota approved vent systems
and vent caps.
A non-combustible hearth protector with a total insulation rating of R-1 is required when installing this fireplace directly on the
floor and must extend a minimum of 18" in front of the fireplace. For every 1 inch the fireplace is raised off the floor, the depth of
the hearth protector may be reduced by 2 inches. If fireplace is raised off the floor 6" or more, no hearth protector is required.
HEATING PERFORMANCE:
With its high heat output this Mendota Fireplace will heat a large area of your home if located properly to maximize heat/ air cir-
culation. Air movement options for maximizing heat circulation that can be considered are the continuous operation of central
heating furnace blowers or ceiling fans.
The most efficient method for overall heat distribution within a single room is a
ceiling fan.
The heat output of the Fireplace can be reduced to a low 7,000 BTUH by turning off the Rear Burner and reducing
flame height using the remote control. Blower can be turned down or turned off to reduce heat distribution.
AESTHETIC CONSIDERATIONS:
Burning or static fireplaces are a major aesthetic focus in any room. Locate your gas fireplace as you would a television set.
The Mendota Hearth Gas Fireplace will be a continuing source of comfort and fascination. Corner installations will afford you
the greatest potential for viewing in many rooms. We suggest installing this Mendota Fireplace a minimum of 12 inches above
the floor by utilizing an elevated hearth. This fireplace may be installed in an elevated position as long as 72 in. minimum dis-
tance is provided between the floor level of this fireplace and the room’s ceiling surface.
ELECTRICAL REQUIREMENTS:
Electronic Ignition System, Dual Blowers and an Accent Light system are included in this Mendota Direct Vent Fireplace. These
devices require constant electrical power except during power outages. A 115-volt electrical service must be supplied at the
fireplace location at the time of installation, on the left side of this fireplace. It must be electrically grounded in accordance with
local codes, or in their absence, with the current edition of the National Electric Code ANSI/NFPA 70. Use of a wall switch con-
trol in the power supplied to this fireplace is NOT allowed.
Thermostatic function is included in the Remote Control Transmitter. Therefore, no Thermostat wire is required.
MANUAL GAS SHUTOFF VALVE INSTALLATION REQUIREMENT
A manual Shutoff Ball valve is factory installed in the appliance and is accessible through the air gap on the left of the
glass frame. Use the glass latch tool to operate the Shutoff Ball valve. If local building codes require, obtain an external
Wall Mounted Manual Gas Shutoff Valve approved per local gas plumbing codes and install per local gas plumbing codes