Service Manual
1-119
INSTALLATION
4. Installation
Location
Figure 4.1 Operation and Installation Space
,QVWDOOWKHLQGRRUXQLWDOORZLQJIRUSURSHU
clearance for operation and maintenance
DFFHVVDVVKRZQLQ)LJXUH
Rear Side
≥ 39-3/8
≥ 39-3/8
View from Top
Front Side
(5-1/8)
≥ 23-5/8
≥ 23-5/8
Electrical Box
(Unit: inch)
Service Access
Door (≥ □17-23/32)
In case that the
ceiling board can
not be detected
for servicing,
prepare a service
access door
below the indoor
unit for removing
the indoor unit.
&RQVLGHUWKHDLUGLVWULEXWLRQIURPWKHLQGRRUXQLWWRWKHVSDFHRIWKHURRPDQGVHOHFWDVXLWDEOHORFDWLRQ
so that uniform air temperature in the room can be obtained.
(3) Do not leave combustible materials inside the service space of the indoor unit.
$YRLGREVWDFOHVZKLFKPD\KDPSHUWKHDLULQWDNHRUWKHDLUGLVFKDUJHÀRZ
'RQRWLQVWDOOWKHLQGRRUXQLWLQDPDFKLQHVKRSRUNLWFKHQZKHUHYDSRUIURPRLORULWVPLVWÀRZVWRWKH
indoor unit.
7KHRLOZLOOGHSRVLWRQWKHKHDWH[FKDQJHUWKHUHE\UHGXFLQJWKHLQGRRUXQLWSHUIRUPDQFHDQGPD\
GHIRUPDQGLQWKHZRUVWFDVHEUHDNWKHSODVWLFSDUWVRIWKHLQGRRUXQLW
(6) Pay attention to the following points when the indoor unit is installed in a hospital or other facilities
where there are electronic waves from medical equipment.
(a) Do not install the indoor unit where the electromagnetic wave is directly radiated to the electrical
ER[FRPPXQLFDWLRQFDEOHRUZLUHGFRQWUROOHU
(b) Install the indoor unit and components as far away as practical or at least 9.8ft (3m) from any
electromagnetic wave radiator.
(c) Prepare a steel box and install the wired controller in it. Prepare a steel conduit tube and wire the
FRQWUROOHUFDEOHLQLW7KHQFRQQHFWWKHJURXQGZLULQJZLWKWKHER[DQGWKHWXEH
G ,QVWDOODQRLVH¿OWHUZKHQWKHSRZHUVXSSO\HPLWVKDUPIXOQRLVHV
7RDYRLGDQ\FRUURVLYHDFWLRQWRWKHKHDWH[FKDQJHUVGRQRWLQVWDOOWKHLQGRRUXQLWLQDQDFLGRUDONDOLQH
environment.
5. Installation
Work
5.1 Suspension
Bolts
'HWHUPLQHWKH¿QDOORFDWLRQDQGLQVWDOODWLRQ
orientation of the indoor unit with respect
WRWKHVSDFHDOORZHGIRUSLSLQJZLULQJDQG
maintenance access.
0RXQWVXVSHQVLRQEROWVDVVKRZQLQ
Figure 5.1.
5-29/32 to 6-5/16
Insert
(221 to 331 lbs)
I Beam
(inch)
Suspension Bolt
(W3/8 or M10)
Anchor Bolt
(W3/8 or M10)
Steel
Concrete
For Wooden Beam Suspension
Wooden Bar
(2-3/8 to 3-17/32 Square)
Wooden Beam
Nut
Nut
Square Washer
Square Washer
Suspension Bolt
For Concrete Slab
For Steel Beam
Figure 5.1 Mounting of Suspension Bolts
Содержание YVAHP072B31S
Страница 2: ......
Страница 10: ...viii Service Manual ...
Страница 16: ......
Страница 17: ...Service Manual 1 1 INSTALLATION 1 Installation ...
Страница 559: ...Service Manual 1 543 INSTALLATION 7 7RXFK DFN WR QLVK WKLV VHWWLQJ The screen returns to the Service Menu screen 7 ...
Страница 577: ...Service Manual 1 561 INSTALLATION 9 Touch Back to return to the Service Menu screen 9 ...
Страница 920: ......
Страница 921: ...Service Manual 2 1 OPERATION 2 Operation ...
Страница 983: ...Service Manual 2 63 OPERATION Clipped Ceiling Type Grille for Front Discharge 2SWLRQDO Decorative Panel 2SWLRQDO ...
Страница 1184: ...2 264 Service Manual OPERATION 7 Touch on Return to Group sel to return to Setting Group Selection 7 ...
Страница 1315: ...Service Manual 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Страница 1425: ...Service Manual 3 111 TROUBLESHOOTING Surge Absorber SA Surge Absorber SA Surge Absorber SA 3RVLWLRQ RI 6XUJH EVRUEHU 9 9 1 1 1 ...
Страница 1461: ...Service Manual 4 1 MAINTENANCE 4 Maintenance ...
Страница 1657: ...Service Manual 5 1 EXTERNAL INPUT OUTPUT AND FUNCTION SETTING 5 External Input Output and Function Setting ...
Страница 1728: ......
Страница 1729: ...Service Manual 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Страница 1738: ...6 10 Service Manual FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A ft 3 l b ...
Страница 1739: ...SERVICE PARTS LIST Service Manual 7 1 7 Service Parts List ...
Страница 1795: ......
Страница 1796: ... 2015 Johnson Controls Inc SM 15001 ...