Appendix 2: Reporting Codes
Section #
Definition
Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
Repeater 7 tamper/restore alarm
T/R
E(3)83-907 / R (3)83-907
TA-0907 / TR-0907
Repeater 8 tamper/restore alarm
T/R
E(3)83-908 / R (3)83-908
TA-0908 / TR-0908
Keypad Lockout - Incorrect access code entry
T/R
E(4)61-000 / R(4)61-000
JA-0000
Opening Events
User Openings - Disarmed by user
O/C
E(4)A1-UUU
OP-UUUU
Automatic Arming Canceled
O/C
E(4)64-UUU
CI-0000
Special Opening - System disarmed using: keyswitch, main-
tenance code, DLS software, wireless key
O/C
E(4)AA-000
OP-0000
Closing Events
User Closings - System armed by user, wireless key
O/C
R(4)A1-UUU
CL-UUUU
Partial Closing - 1 or more zones bypassed when armed
O/C
E(4)56-000
CG-0000
Special Closing - System armed via: quick arm, keyswitch, func-
tion key, maintenance code, DLS software
O/C
R(4)AA-000
CL-0000
Exit Fault
O/C
E(3)74-ZZZ
EA-ZZZZ
Automatic (Schedule) Closing
O/C
R (4)A3-000
CA-0000
System Trouble Events
General system tamper/restore (while armed)
MA/R
E(1)37-000/ R(1)37-000
ES-0000/EJ-0000
General system tamper/restore (while disarmed)
MA/R
E(1)37-000/ R(1)37-000
ES-0000/EJ-0000
Battery trouble/restore - Main panel
MA/R
E(3)A2-000 / R(3)A2-000
YT-0000 / YR-0000
Battery absent trouble/restore - Main panel
MA/R
E(3)11-000 / R(3)11-000
YM-0000 / YR-0000
Battery charging trouble/restore
MA/R
E(3)14-000/ R(3)14-000
YP-0000/ YQ-0000
Panel AC trouble/restore - Main panel
MA/R
E(3)A1-000 / R(3)A1-000
AT-0000 / AR-0000
Battery over voltage charge/restore
MA/R
E(3)14-000/ R(3)14-000
YP-000/YQ-000
Alternate Communicator
Alternate Communicator radio/SIM trouble/restore
MA/R
E(3)AA-001
R(3)AA-001
YX-0001 / YZ-0001
Alternate CommunicatorGSM Network trouble/restore
MA/R
E(3)AA-001
R(3)AA-001
YX-0001 / YZ-0001
Alternate Communicator Ethernet trouble/restore
MA/R
E(3)AA-001
R(3)AA-001
YX-0001 / YZ-0001
Alternate Communicator Receiver 1 absent/restore
MA/R
E(3)5A-001
R(3)5A-001
YS-0001 / YK-0001
Alternate Communicator Receiver 2 absent/restore
MA/R
E(3)5A-002
R(3)5A-002
YS-0002 / YZ-0002
Alternate Communicator Receiver 3 absent/restore
MA/R
E(3)5A-003
R(3)5A-003
YS-0003 / YZ-0003
Alternate Communicator Receiver 4 absent/restore
MA/R
E(3)5A-004
R(3)5A-004
YS-0004 / YZ-0004
Alternate Communicator Receiver 1 Supervisory trouble/restore
MA/R
E(3)5A-001/R(3)5A-001
YS-0001 / YK-0001
Alternate Communicator Receiver 2 Supervisory trouble/restore
MA/R
E(3)5A-002/R(3)5A-002
YS-0002 / YK-0002
Alternate Communicator Receiver 3 Supervisory trouble/restore
MA/R
E(3)5A-003/R(3)5A-003
YS-0003 / YK-0003
Alternate Communicator Receiver 4 Supervisory trouble/restore
MA/R
E(3)5A-004/R(3)5A-004
YS-0004 / YK-0004
Alternate Communicator SMS Config trouble/restore
MA/R
E(3)AA-001
R(3)AA-001
YX-0001 / YZ-0001
Remote Programming Begin/End
MA/R
E(6)27-000 / E(6)28-000
LB-0000 / LS-0000
FTC trouble/restore
MA/R
E(3)54-RRR/ R(3)54-RRR
YC-RRR/YK-RRR
Receiver not available trouble/restore
MA/R
E(3)5A-RRR/ R(3)5A-RRR
YS-RRR/YK-RRR
Receiver supervisory trouble/restore
MA/R
E(3)5A-RRR/ R(3)5A-RRR
YS-RRR/YK-RRR
Wireless Events
Wireless Zone Low Battery trouble/restore.
MA/R
E(3) 84-ZZZ
R(3) 84-ZZZ
XT-ZZZZ / XR-ZZZZ
- 48 -