1083163-UIM-J-0918
Johnson Controls Unitary Products
15
FIGURE 17:
Upflow Configuration
INDUCER ROT
A
TED FOR
LEFT
SIDE VENTING
UPFLOW
AS RECEIVED
INDUCER ROT
A
TED FOR
RIGHT
SIDE VENTING
When drain hose routing changes are required, be sure to cap all un-used openings.
If rerouting hoses - excess length should be cut of
f so that no sagging loops will collect
and hold condensate, which will cause the furnace to not operate.
Shorten
pressure
switch hose
Re-route and
shorten
pressure
switch hose
Shorten
rain
gutter
hose
Move rain
gutter hose
to this position
For 100 & 120 input furnaces, the condensate
drain is plumbed toward the left casing outlet from the factory.
For 040, 060 & 080K input furnaces, the condensate
drain is plumbed toward the right casing outlet from the factory.
Condensate drain may exit cabinet on either side.
1
2
1
2