The following messages apply to wiring this product.    

 

Setup and Adjustments

Make temperature or fan speed adjustments using the 
rotating dial, shown in Figure 3 and Figure 5.

Repair Information

Do not field repair the TM-21x1 Series Room 
Temperature Module. As with any electrical device, 
keep the air vents clean and free from dust and 
obstruction. To order replacement parts, contact the 
nearest Johnson Controls representative.

!

CAUTION: Risk of Electric Shock. 

Disconnect power supply before making 
electrical connections to avoid electric 
shock. 

Mise En Garde: Risque de décharge 
électrique.

 Débrancher l'alimentation 

avant de réaliser tout raccordement 
électrique afin d'éviter tout risque de 
décharge électrique.

!

CAUTION: Risk of Property Damage.

 

Do not run low voltage cable in the same 
conduit or wiring troughs with high 
voltage wires. Running low and high 
voltage wires in the same conduit or 
wiring troughs may damage the 
equipment or cause system malfunction.

 

MISE EN GARDE : Risque de dégâts 
matériels.

Ne pas faire courir un câble basse 
tension dans les mêmes gaines ou 
goulottes électriques que des câbles 
haute tension. L'installation de fils basse 
tension et haute tension dans les mêmes 
gaines ou goulottes électriques risque 
d'endommager l'équipement ou de 
provoquer des dysfonctionnements du 
système.  

!

CAUTION: Risk of Property Damage.

 

Do not apply power to the system before 
checking all wiring connections. Short 
circuited or improperly connected wires 
may result in permanent damage to the 
equipment. 

Mise En Garde: Risque de dégâts 
matériels. 

Ne pas mettre le système 

sous tension avant d'avoir vérifié tous les 
raccords de câblage. Des fils formant un 
court-circuit ou connectés de façon 
incorrecte risquent d'endommager 
irrémédiablement l'équipement.

IMPORTANT:

Use copper conductors only. Make 

all wiring connections in accordance with local, 
national, and regional regulations. Do not exceed 
the Temperature Module electrical ratings.

Содержание TM-2161

Страница 1: ...iode LED that indicates the current operating mode Installation Parts Included Two 6 32 x 7 8 in 22 mm wallbox mounting screws are included with the TM 21x1 Module Special Tools Needed For tightening and loosening the TM 11x1 Series Room Temperature Module security screw order the optional Allen head tool T 4000 119 from the nearest Johnson Controls representative IMPORTANT The TM 21x1 Series Room...

Страница 2: ...re 2 TM 2151 Dimensions in mm FIG 2151_dim Mode LED Occupancy Button 3 15 80 1 26 32 4 72 120 Figure 3 TM 2161 0002 and TM 2161 0007 Dimensions in mm FIG 2161_dim 1 38 35 4 72 120 3 15 80 Mode LED Occupancy Button Fan Speed Dial Setpoint Adjustment Dial FIG 2161_0005_dim 1 38 35 4 72 120 3 15 80 Mode LED Occupancy Button Setpoint Adjustment Dial Figure 4 TM 2161 0000 and TM 2161 0005 Dimensions in...

Страница 3: ...ing Location Considerations Mount the TM 21x1 Series Room Temperature Module on a wall in the room to be controlled where the occupant can easily read and adjust the setpoint dial or fan speed override adjustment dial Consider these additional guidelines in determining the best mounting location Avoid areas subject to excessive vibration electrical noise direct sunlight or the effects of radiant h...

Страница 4: ...turing an NTC Sensor with Temperature Setpoint Adjustment and Occupancy Override FIG 2161_0005_WIR 15 14 21 20 NTC Sensor Common Mode LED Occupancy Button 23 22 Room Temperature Module DC 5 V Temperature Setpoint Figure 9 Wiring to a Room Temperature Module Featuring an NTC Sensor with Temperature Setpoint Adjustment Occupancy Override and Three Speed Fan Override FIG 2161_0207_WIR 15 14 21 20 NTC...

Страница 5: ...Running low and high voltage wires in the same conduit or wiring troughs may damage the equipment or cause system malfunction MISE EN GARDE Risque de dégâts matériels Ne pas faire courir un câble basse tension dans les mêmes gaines ou goulottes électriques que des câbles haute tension L installation de fils basse tension et haute tension dans les mêmes gaines ou goulottes électriques risque d endo...

Страница 6: ...perature Output with Setpoint Adjustment Power Requirements 5 VDC Power Consumption N A Refer to individual component specification Inputs None Adjustments Temperature Setpoint Fan Speed Optional by Model Mode Indicator Green LED 5 V 4 mA Occupancy Button Momentary Contact Switch 5 V at 1 mA Output Temperature Sensing Element Resistance Temperature Device RTD Thermistor Negative Temperature Coeffi...

Страница 7: ...d III TM 21x1 0005 10k ohm potentiometer marked for 5F TM 21x1 0007 10k ohm potentiometer marked for 5F Fan Speed Adjustment Auto Off I II and III Accuracy 0 9 F 0 5 C Field Connection 18 to 22 AWG 1 00 to 0 65 mm diameter recommended Mounting Wallbox Mount Housing Material ABS PC Self Extinguishing HB UL94 Protection IP30 EN 60529 Ambient Operating Conditions 32 to 122 F 0 to 50 C 10 to 90 RH non...