background image

TM-11x1 Series Room Temperature Module Installation Instructions

2

Dimensions

TM-1141 Modules 

TM-1151 Modules  

TM-1161 Modules

  

TM-1191 Modules

 

 

Figure 1: TM-1141 Dimensions, in. (mm)

Figure 1: TM-1141 Dimensions, in. (mm)

3.15 (80)

1.26 (32)

4.72

(120)

F

IG

:T

M

4

1

_

d

im

Figure 2: TM-1151 Dimensions, in. (mm)

F

IG

:T

M

5

1

_

d

im

Mode

LED

Occupancy

Button

3.15 (80)

1.26 (32)

4.72

(120)

Figure 3: TM-1161 Dimensions, in. (mm)

F

IG

:T

M

6

1

_

d

im

1.38 (35)

4.72

(120)

3.15 (80)

Mode

LED

Occupancy

Button

Fan

Speed

Dial

Setpoint

Adjustment

Dial

Figure 4: TM-1191 Dimensions, in. (mm)

F

IG

:T

M

9

1

_

d

im

3.15 (80)

1.38 (35)

4.72

(120)

Setpoint

Adjustment

Dial

Содержание TM-11x1 series

Страница 1: ...speed fan override adjustment is available and models without a temperature sensor are provided for applications where the room temperature sensor is mounted inside the Fan Coil Unit Installation Parts Included Two 6 32 x 7 8 in 22 mm wallbox mounting screws are included with the TM 11x1 Module Special Tools Needed For tightening and loosening the TM 11x1 Series Room Temperature Module security sc...

Страница 2: ...141 Dimensions in mm 3 15 80 1 26 32 4 72 120 FIG TM41_dim Figure 2 TM 1151 Dimensions in mm FIG TM51_dim Mode LED Occupancy Button 3 15 80 1 26 32 4 72 120 Figure 3 TM 1161 Dimensions in mm FIG TM61_dim 1 38 35 4 72 120 3 15 80 Mode LED Occupancy Button Fan Speed Dial Setpoint Adjustment Dial Figure 4 TM 1191 Dimensions in mm FIG TM91_dim 3 15 80 1 38 35 4 72 120 Setpoint Adjustment Dial ...

Страница 3: ...th the allen head tool Mounting Location Considerations Mount the TM 11x1 Series Room Temperature Module on a wall in the room to be controlled Locate it where the occupant can easily read and adjust the setpoint dial or fan speed override adjustment dial Consider these additional guidelines to determine the best mounting location Avoid areas subject to excessive vibration electrical noise direct ...

Страница 4: ...e Setpoint Adjustment and Occupancy Override FIG TM61_WIR 15 14 21 20 NTC Sensor Common Mode LED Occupancy Button 23 22 15 14 21 20 23 22 Controller Room Temperature Module DC 5 V Temperature Setpoint Figure 8 Wiring to a Room Temperature Module Featuring an NTC Sensor with Temperature Setpoint Adjustment Occupancy Override and Three Speed Fan Override FIG TM61_WIR2 15 14 21 20 NTC Sensor Common M...

Страница 5: ...t ou de provoquer des dysfonctionnements du système CAUTION Risk of Property Damage Do not apply power to the system before checking all wiring connections Short circuited or improperly connected wires may result in permanent damage to the equipment Mise En Garde Risque de dégâts matériels Ne pas mettre le système sous tension avant d avoir vérifié tous les raccords de câblage Des fils formant un ...

Страница 6: ...k ohm potentiometer marked for 5F TM 11x1 0007 10k ohm potentiometer marked for 5F Fan Speed Adjustment Auto Off I II and III Accuracy 0 9 F 0 5 C Field Connection 18 to 22 AWG 1 00 to 0 65 mm diameter recommended Mounting Wallbox Mount Housing Material ABS PC Self Extinguishing HB UL94 Protection IP30 EN 60529 Ambient Operating Conditions Temperature 32 to 122 F 0 to 50 C Humidity 10 to 90 RH Non...

Отзывы: