background image

Published in U.S.A.

www.johnsoncontrols.com

TM-11x1 Series Room Temperature Module Installation Instructions

6

Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.

All other marks herein are the marks of their respective owners. © 2016 Johnson Controls, Inc.

Building Efficiency

507 E. Michigan Street, Milwaukee, WI  53202

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these 
specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or 
misuse of its products.

Setpoint Range

TM-1141-0000
TM-1151-0000

No setpoint range

TM-1161-0000
TM-1191-0000

10k ohm potentiometer marked for 55 to 85°F

TM-11x1-0002

10k ohm potentiometer marked for 55 to 85°F 
Fan Speed Adjustment: Auto, Off, I, II, and III

TM-11x1-0005

10k ohm potentiometer marked for +/- (5F°)

TM-11x1-0007

10k ohm potentiometer marked for +/- (5F°)
Fan Speed Adjustment: Auto, Off, I, II, and III

Accuracy

±0.9°F (±0.5°C)

Field Connection

18 to 22 AWG (1.00 to 0.65 mm diameter) recommended

Mounting

Wallbox Mount

Housing Material

ABS + PC, Self-Extinguishing HB UL94

Protection

IP30 (EN 60529)

Ambient Operating Conditions

Temperature

32 to 122°F (0 to 50°C)

Humidity

10 to 90% RH (Noncondensing)

Ambient Storage Conditions

Temperature

-40 to 158°F (-40 to 70°C)

Humidity

5 to 95% RH (Noncondensing)

Dimensions
(H x W x D)

TM-1141
TM-1151

4.72 x 3.15 x 1.26 in. 
(120 x 80 x 32 mm)

TM-1161
TM-1191

4.72 x 3.15 x 1.38 in. 
(120 x 80 x 35 mm)

Shipping Weight

0.44 lb (0.2 kg)

Compliance

Europe

CE Mark: EMC Directive, EN-61000-6-2

European Single Point of Contact:

NA/SA Single Point of Contact:

APAC Single Point of Contact:

JOHNSON CONTROLS
WESTENDHOF 3
45143 ESSEN
GERMANY

JOHNSON CONTROLS
507 E MICHIGAN ST
MILWAUKEE WI 53202
USA

JOHNSON CONTROLS
C/O CONTROLS PRODUCT 
MANAGEMENT
NO. 22 BLOCK D NEW DISTRICT
WUXI JIANGSU PROVINCE 214142
CHINA

TM-11x1 Series

 

Room Temperature Module (Part 2 of 2

)

Содержание TM-11x1 series

Страница 1: ...speed fan override adjustment is available and models without a temperature sensor are provided for applications where the room temperature sensor is mounted inside the Fan Coil Unit Installation Parts Included Two 6 32 x 7 8 in 22 mm wallbox mounting screws are included with the TM 11x1 Module Special Tools Needed For tightening and loosening the TM 11x1 Series Room Temperature Module security sc...

Страница 2: ...141 Dimensions in mm 3 15 80 1 26 32 4 72 120 FIG TM41_dim Figure 2 TM 1151 Dimensions in mm FIG TM51_dim Mode LED Occupancy Button 3 15 80 1 26 32 4 72 120 Figure 3 TM 1161 Dimensions in mm FIG TM61_dim 1 38 35 4 72 120 3 15 80 Mode LED Occupancy Button Fan Speed Dial Setpoint Adjustment Dial Figure 4 TM 1191 Dimensions in mm FIG TM91_dim 3 15 80 1 38 35 4 72 120 Setpoint Adjustment Dial ...

Страница 3: ...th the allen head tool Mounting Location Considerations Mount the TM 11x1 Series Room Temperature Module on a wall in the room to be controlled Locate it where the occupant can easily read and adjust the setpoint dial or fan speed override adjustment dial Consider these additional guidelines to determine the best mounting location Avoid areas subject to excessive vibration electrical noise direct ...

Страница 4: ...e Setpoint Adjustment and Occupancy Override FIG TM61_WIR 15 14 21 20 NTC Sensor Common Mode LED Occupancy Button 23 22 15 14 21 20 23 22 Controller Room Temperature Module DC 5 V Temperature Setpoint Figure 8 Wiring to a Room Temperature Module Featuring an NTC Sensor with Temperature Setpoint Adjustment Occupancy Override and Three Speed Fan Override FIG TM61_WIR2 15 14 21 20 NTC Sensor Common M...

Страница 5: ...t ou de provoquer des dysfonctionnements du système CAUTION Risk of Property Damage Do not apply power to the system before checking all wiring connections Short circuited or improperly connected wires may result in permanent damage to the equipment Mise En Garde Risque de dégâts matériels Ne pas mettre le système sous tension avant d avoir vérifié tous les raccords de câblage Des fils formant un ...

Страница 6: ...k ohm potentiometer marked for 5F TM 11x1 0007 10k ohm potentiometer marked for 5F Fan Speed Adjustment Auto Off I II and III Accuracy 0 9 F 0 5 C Field Connection 18 to 22 AWG 1 00 to 0 65 mm diameter recommended Mounting Wallbox Mount Housing Material ABS PC Self Extinguishing HB UL94 Protection IP30 EN 60529 Ambient Operating Conditions Temperature 32 to 122 F 0 to 50 C Humidity 10 to 90 RH Non...

Отзывы: