background image

TM-11x1 Series Room Temperature Module Installation Instructions

1

Applications

The TM-11x1 Series of Room Temperature Modules 
are designed for use with the TC-9102 Direct Digital 
Control (DDC) terminal unit controller. The setpoint dial 
enables the room occupant to adjust the working 
setpoint of the controller. On scaled models, the 
marked adjustment range is 55 to 85°F; the controller 
determines the actual setpoint. On Warmer/Cooler 
models, the adjustment range is /-

 

from the 

midpoint of the dial; the controller determines the 
equivalent setpoint temperature. 

With the occupancy button, the occupant can switch 
the controller’s operating mode between occupied and 
standby. In addition, the TM-11x1 Series offers the 
option of a temporary occupied mode during 
unoccupied mode. 

The TM-11x1 Series Room Temperature Module also 
features a Light-Emitting Diode (LED) that indicates the 
current operating mode.

For TC-9102 Fan Coil Unit controllers, a Room 
Temperature Module with a 3-speed fan override 
adjustment is available, and models without a 
temperature sensor are provided for applications 
where the room temperature sensor is mounted inside 
the Fan Coil Unit. 

Installation

Parts Included

Two #6-32 x 7/8 in. (22 mm) wallbox mounting screws 
are included with the TM-11x1 Module.

Special Tools Needed

For tightening and loosening the TM-11x1 Series Room 
Temperature Module security screw, order the optional 
Allen-head tool (T-4000-119) from the nearest 
Johnson Controls® representative.

IMPORTANT:

The TM-11x1 Series Room 

Temperature Modules are intended to provide an 
input to equipment under normal operating 
conditions. Where failure or malfunction of the 
TM-11x1 Temperature Module could lead to 
personal injury or property damage to the controlled 
equipment or other property, other precautions must 
be designed into the control system. Incorporate and 
maintain other devices, such as supervisory or 
alarm systems, or safety or limit controls intended to 
warn of or protect against failure or malfunction of 
the TM-11x1 Temperature Module.

TM-11x1 Series Room Temperature Module

Installation Instructions

Part No. 24-10225-4, Rev. C

Issued March 2016

24- 10225- 4,  Rev .  C

Содержание TM-11x1 series

Страница 1: ...speed fan override adjustment is available and models without a temperature sensor are provided for applications where the room temperature sensor is mounted inside the Fan Coil Unit Installation Parts Included Two 6 32 x 7 8 in 22 mm wallbox mounting screws are included with the TM 11x1 Module Special Tools Needed For tightening and loosening the TM 11x1 Series Room Temperature Module security sc...

Страница 2: ...141 Dimensions in mm 3 15 80 1 26 32 4 72 120 FIG TM41_dim Figure 2 TM 1151 Dimensions in mm FIG TM51_dim Mode LED Occupancy Button 3 15 80 1 26 32 4 72 120 Figure 3 TM 1161 Dimensions in mm FIG TM61_dim 1 38 35 4 72 120 3 15 80 Mode LED Occupancy Button Fan Speed Dial Setpoint Adjustment Dial Figure 4 TM 1191 Dimensions in mm FIG TM91_dim 3 15 80 1 38 35 4 72 120 Setpoint Adjustment Dial ...

Страница 3: ...th the allen head tool Mounting Location Considerations Mount the TM 11x1 Series Room Temperature Module on a wall in the room to be controlled Locate it where the occupant can easily read and adjust the setpoint dial or fan speed override adjustment dial Consider these additional guidelines to determine the best mounting location Avoid areas subject to excessive vibration electrical noise direct ...

Страница 4: ...e Setpoint Adjustment and Occupancy Override FIG TM61_WIR 15 14 21 20 NTC Sensor Common Mode LED Occupancy Button 23 22 15 14 21 20 23 22 Controller Room Temperature Module DC 5 V Temperature Setpoint Figure 8 Wiring to a Room Temperature Module Featuring an NTC Sensor with Temperature Setpoint Adjustment Occupancy Override and Three Speed Fan Override FIG TM61_WIR2 15 14 21 20 NTC Sensor Common M...

Страница 5: ...t ou de provoquer des dysfonctionnements du système CAUTION Risk of Property Damage Do not apply power to the system before checking all wiring connections Short circuited or improperly connected wires may result in permanent damage to the equipment Mise En Garde Risque de dégâts matériels Ne pas mettre le système sous tension avant d avoir vérifié tous les raccords de câblage Des fils formant un ...

Страница 6: ...k ohm potentiometer marked for 5F TM 11x1 0007 10k ohm potentiometer marked for 5F Fan Speed Adjustment Auto Off I II and III Accuracy 0 9 F 0 5 C Field Connection 18 to 22 AWG 1 00 to 0 65 mm diameter recommended Mounting Wallbox Mount Housing Material ABS PC Self Extinguishing HB UL94 Protection IP30 EN 60529 Ambient Operating Conditions Temperature 32 to 122 F 0 to 50 C Humidity 10 to 90 RH Non...

Отзывы: