background image

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy 
Sensing Capability Installation Instructions

2

Note:

Allow for vertical air circulation to the thermostat 

controller.

To install the thermostat controller:

1.

Use a Phillips-head screwdriver to remove the 
security screw if it is installed on the bottom of the 
thermostat controller cover.

Note:

Normally, the security screw comes packaged 

separately in a plastic bag with the thermostat 
controller. Skip this step if the screw is not installed on 
the bottom of the cover.

2.

Pull the bottom edge of the thermostat controller 
cover and open the thermostat controller as 
illustrated in Figure 1.

Note:

PIR models have a wiring connection between 

the cover and the Printed Circuit Board (PCB). This 
connection allows for proper wiring of the occupancy 
sensor. Carefully remove the wiring connection from 
the PCB by pulling up on the connector block. Do not 
attempt to remove the connector block by pulling on the 
wires.  

3.

Carefully pull the locking tabs on the right side of 
the thermostat controller mounting base and 
unlock the PCB. Open the PCB to the left as 
illustrated in Figure 2.

4.

Pull approximately 6 in. (152 mm) of wire from the 
wall and insert the wire through the hole in the 
thermostat controller mounting base.

5.

Align the thermostat controller mounting base on 
the wall and use the base as a template to mark 
the two mounting hole locations.

Note:

Be sure to position the thermostat controller 

mounting base so that the arrow on the base points 
upward to indicate the top of the thermostat controller.  

6.

Drill a 3/16 in. (5 mm) hole at each of the two 
marked locations and tap nylon anchors (included 
with the thermostat controller) flush to the wall 
surface.

Note:

Other means of anchoring the device may be 

desired, depending on the wall medium.

7.

Position the thermostat controller mounting base 
on the wall and use the two mounting screws 
(included with the thermostat controller) to secure 
the base to the wall surface as illustrated in 
Figure 3.

Note:

Be careful not to overtighten the mounting 

screws.  

8.

Swing the PCB back to the right and carefully snap 
it into the locking tabs on the thermostat controller 
mounting base.

Figure 1: Removing the

Thermostat Controller Cover

(T60xDFH-4+PIR Model Shown)

F

IG

:c

v

r_

rm

v

l

Figure 2: Opening the

Thermostat Controller PCB

F

IG

:p

rc

rc

tb

rd

PCB
Locking
Tabs

Figure 3: Securing the Thermostat Controller 

Mounting Base to the Wall

F

IG

:m

n

tb

s

Содержание T60xDFH 4 PIR Series

Страница 1: ...ge grills or stairwells and from behind doors away from steam or water pipes warm air stacks unconditioned areas not heated or cooled or sources of electrical interference For integrated Passive Infra...

Страница 2: ...the left as illustrated in Figure 2 4 Pull approximately 6 in 152 mm of wire from the wall and insert the wire through the hole in the thermostat controller mounting base 5 Align the thermostat contr...

Страница 3: ...mperature readings 3 Reinsert the screw terminal blocks onto the PCB Note If multiple wires are inserted into the terminals be sure to properly twist the wires together prior to inserting them into th...

Страница 4: ...Fan H Fan H Fan H Fan On High 2 Fan M Fan M Fan M Fan On Medium 3 Fan L Fan L Fan L Fan On Low 4 24 V Hot 24 V Hot 24 V Hot 24 VAC from Transformer 5 24 V Com 24 V Com 24 V Com 24 VAC Common from Tran...

Страница 5: ...Alarm Voltage Free Contact Remote NSB Motion Window OR Same 24 VAC Power Source for Auxiliary Output 24 VAC Maximum Separate 24 VAC Power Source for Auxiliary Output 24 VAC Maximum BO5 Aux BO5 Aux 24...

Страница 6: ...Pipe Applications Four Pipe Applications FIG T6023dfh3ooc 24 V Com 24 V Hot or 24 V Com 24 V Hot Cooling Valve or Heating Valve or Figure 8 Wiring T602DFH 4 and T603DFH 4 Thermostat Controllers for F...

Страница 7: ...perature scale to either Celsius or Fahrenheit and allow access to the Installer Configuration Menu See the Configuring the T60xDFH 4 and T60xDFH 4 PIR Series Thermostat Controller section Use the UP...

Страница 8: ...ehumidification operation If the thermostat controller is in Cooling demand the chilled water valve opens to 100 the thermostat controller stages Heating to maintain the room temperature at the Coolin...

Страница 9: ...PIR sensing device used If movements are detected by the PIR sensor and the door is closed the room is considered occupied The thermostat controller switches back to Stand By mode only if the door sw...

Страница 10: ...nu begins press and release the center key to scroll through the parameters listed in Table 4 3 When the desired parameter is displayed use the UP DOWN arrow keys to choose the desired selection optio...

Страница 11: ...eration in Four Pipe Applications Selection Option Control Curve Terminal Numbers Used See Table 1 and Figure 5 On Off Control Floating Control Proportional 0 to 10 VDC Control 0 Cooling Only See Figu...

Страница 12: ...16 Cooling with Reheat Two or Four Pipe Applications Temperature Increase Increments of 1F 0 5C Heating Setpoint Device Closed Cooling Setpoint Device Opened FIG clng_wth_rht Deadband Reheat On Off Fl...

Страница 13: ...ng Figure 20 This operation applies to the Occupied mode when the fan is set to Auto Figure 19 Heating Cooling with Reheat Four Pipe Applications Temperature Increase Increments of 1F 0 5C Heating Set...

Страница 14: ...at controller remains in the Occupied mode if the contact is open until the TOccTime expires Advanced PIR occupancy functions using a Normally Open N O or Normally Closed N C remote PIR motion sensor...

Страница 15: ...an input COC NH Changeover Contact Normally Heat A dry contact input is used to signal seasonal hot cold water changeover The contact closes when cold water is present Valid only for two pipe systems...

Страница 16: ...sequence of operation Default 1 Sequence of Operation Default Based on AutoMode Parameter Setting On Off 0 Cooling Only Off Cool Cool Cool 1 Heating Only Off Heat Heat Heat 2 Cooling and Reheat Off Au...

Страница 17: ...ive Range 0 5 to 24 0 hrs adjustable in 0 5 hour increments Unocc TM Sets the Unoccupied timer value PIR models Default 0 0 hours Time delay between the moment the thermostat controller toggled to Sta...

Страница 18: ...d between the return and supply air feeds that is directly influenced by the supply air stream 3 3 0F 1 7C 4 4 0F 2 2C 5 5 0F 2 8C 6 6 0F 3 3C 7 7 0F 3 9C 8 8 0F 4 4C 9 9 0F 5 0C 10 10 0F 5 6C Set typ...

Страница 19: ...s the desired humidity sensor calibration offset The offset can be added to or subtracted from the actual displayed room humidity T603 and T605 models This parameter can be used only if the dehumidifi...

Страница 20: ...perature error from the setpoint FL time Sets the maximum actuator stroke timing floating CntrlTyp T602 and T603 models Default 1 5 min Range 0 5 to 9 0 min adjustable in 0 5 minute increments Cph Set...

Страница 21: ...at Controllers with Dehumidification and Occupancy Sensing Capability Part 1 of 2 Power Requirements 19 to 30 VAC 50 60 Hz 2 VA Terminals 4 and 5 at 24 VAC Nominal Class 2 or Safety Extra Low Voltage...

Страница 22: ...2 2 No 24 Temperature Indicating and Regulating Equipment Industry Canada ICES 003 Europe CE Mark Johnson Controls Inc declares that this product is in compliance with the essential requirements and o...

Отзывы: