![Johnson Controls JRE Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/johnson-controls/jre-series/jre-series_installation-operation-and-maintenance_2024185004.webp)
W A T E R - S O U R C E H E A T P U M P S
JRE-Series
R e v. : A u g u s t 1 9 , 2 0 2 0
I n s t a l l a t i o n , O p e r a t i o n , M a i n t e n a n c e
4
General Information
WARNING!
To avoid equipment damage, do not use these
units as a source of heat during the construction process.
The mechanical components and filters used in these units
will quickly become clogged with construction dirt and debris
which may cause system damage.
WARNING!
Some units may be charged with refrigerants
other than 410A and are so labeled. Use appropriate
refrigerant handling techniques. Mixing refrigerants in units
is dangerous and can cause equipment damage. To avoid
the release of refrigerant into the atmosphere, the refrigerant
circuit of this unit must only be serviced by technicians who
meet local, state and federal proficiency requirements.
5. Verify curb is proper size for unit. Install curb
according to manufacturer's instructions prior to
installing unit.
6. Properly size supply and return duct work. Mount
supply air duct to curb before installing unit.
Inspection -
Upon receipt of shipment at the job site,
carefully check the shipment against the bill of lading.
Make sure all units have been received. Inspect the carton
or crating housing of each Rooftop Unit and inspect each
unit for damage. Assure that the carrier makes proper
notation of any shortages or damage on all copies of the
freight bill and that he completes a Carrier Inspection
Report. Concealed damage not discovered during
unloading must be reported to the carrier within 15 days
of receipt of shipment.
NOTE: It is the responsibility
of the purchaser to file all necessary claims with the
carrier.
Storage -
Upon the arrival of equipment at the job site,
immediately store units in a clean, dry area.
Store units
in an upright position at all times.
Stack unit model
numbers JRE-036 through JRE-120 no more than 2
units high. Do not stack units larger than model number
JRE-120.
Do not remove equipment from pallets until
equipment is required for installation
Unit Protection -
Cover rooftop units on the job site.
Cap the open ends of pipes. In areas where painting,
plastering, roofing, or the spraying of fireproof material
has not been completed, all due precautions must
be taken to avoid physical damage to the units and
contamination by foreign material.
Physical damage and
contamination may prevent proper start-up and may
result in costly equipment cleanup.
Pre-Installation -
Installation, operation and maintenance
instructions are provided with each unit. Before unit start-
up, read all manuals and become familiar with the unit
and its operation. Thoroughly check out the system before
operation.
Prepare rooftop units for installation as follows:
1. Compare the electrical data on the unit nameplate
with ordering and shipping information to verify that
the correct unit has been shipped.
2. Select an installation site on the roof which allows
adequate clearance for maintenance and servicing
of the unit. A minimum of two feet of clearance is
required on all service access and drain connection
sides of the unit.
3. Verify that refrigerant tubing is free of kinks or dents,
and that it has not been damaged during shipping.
4. Examine all pipes, fittings, valves and components
before installing the system. Remove any dirt found
on or in these components and assure that all
components are securely fitted.
�
WARNING!
�
�
WARNING!
�
�
CAUTION!
�
CAUTION!
Supply air duct is inaccessible from inside unit
once unit is installed.
WARNING!
The installation of water-source heat pumps and
all associated components, parts, and accessories which
make up the installation shall be in accordance with the
regulations of ALL authorities having jurisdiction and MUST
conform to all applicable codes. It is the responsibility of
the installing contractor to determine and comply with ALL
applicable codes and regulations.
�
WARNING!
�
WARNING!
This product can expose you to chemicals
including formaldehyde, which is known to the state of
California to cause cancer. For more information, go to
www.P65Warnings.ca.gov.
�
WARNING!
�