JRE-Series
R e v. : A u g u s t 1 9 , 2 0 2 0
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y
I n s t a l l a t i o n , O p e r a t i o n , M a i n t e n a n c e
3
Model Nomenclature
Curb
J R
0 3 6
H
D
1
C
A A A A B
1 2
4 5 6
7
8
9
10 11 12
13
14 15
JR = JOHNSON CONTROLS
SERIES
SERIES
REVISION LEVEL
VOLTAGE
CONTROLS
CABINET & FILTER
HEAT EXCHANGER OPTIONS
A = NONE
AIR DAMPER OPTIONS
A = NONE
POWER TERMINATION
B = DISCONNECT
C = DISC GFI OUTLET
STANDARD
C = CXM
BLOWER DRIVE PACKAGE
D = DXM2
L = CXM w/LON
M = DXM2 w/LON
N = CXM w/MPC
P = DXM2 w/MPC
B = MANUAL ADJUSTABLE FRESH AIR DAMPER
B = STANDARD
UNIT SIZE
036
048
060
072
096
120
144
168
240
ETL APPROVED
USA & CANADA
A = STANDARD RPM & STANDARD MOTOR
B = LOW RPM & STANDARD MOTOR
C = HIGH RPM & STANDARD MOTOR
D = STANDARD RPM & LARGE MOTOR
E = HIGH RPM & LARGE MOTOR
D = CIRCUIT BREAKER
E = CIRCUIT B GFI OUTLET
C = MOTORIZED FRESH AIR DAMPER
OPTION
RANGE
2”, (50mm) FILTER
MERV 8
4”, (50mm) FILTER
MERV 8
4”, (100mm) FILTER
MERV 13
THROWAWAY FILTER OPTIONS
1
B
C
3
D
E
EXTENDED
RANGE
STANDARD
RANGE
YES
NO
NO
NO
YES
NO
NO
NO
YES
YES
NO
NO
NO
YES
NO
NO
NO
YES
F = MODULATING ENTHALPY ECONOMIZER
F = HOT GAS BYPASS
REHEAT COIL
3-WAY MOTORIZED VALVE
PROPORTIONAL CONTROL
CIRCULATING PUMP
PUMP CONTACTOR
HOT GAS BYPASS
REHEAT OPTION COMPONENTS
E = ROOFTOP WATER SOURCE
HEAT PUMP
COMPRESSOR TYPE
E
3
{
NON-COATED AIR COILS
COATED AIR COILS
C
T
N
S
A
U
J
W
STANDARD
MOTORIZED VALVE
COPPER (CU)
COAX
CUPRO-NICKEL (CN)
COAX
E
P
D
F
REHEAT
H
Z
G
Y
INTERNAL
SECONDARY PUMP
COPPER (CU)
COAX
CUPRO-NICKEL (CN)
COAX
N = 575/60/3
D= CURRENT ALL SIZES
F = 460/60/3
H = 208-230/60/3
(FACTORY WIRED 208)
A C U R B
A A A A
1 2 3 4 5
9 10 11
12
Model Type
JRE 036 - 072 Standard Curb =
AAA
CURB TYPE and/or Cabinet Size
Curb Constructions
B = Standard 24” High - JRE
C = Horizontal Discharge/RH & LH
Field Changeable - Supply and Return
JRE 168 - 240 Standard Curb =
AAC
JRE 096 -144 Standard Curb =
AAB
G
8
Revision Level
G
= Current Revision
A = Standard 14” High - JRE
R T
6 7
ACURB
= Curb
Series Type
RT =
JRE Series
A
13
Curb Options
B = Welded
C = Welded Vibration Isolation
A = Knocked Down
S = Standard
N
14
Not Used
S
15
Standard
Note: Horizontal curb adapter for TRE only.
End return RH or LH supply, field changable.
Fits on top of digit 12 option A or B.
Digit 13 can be option A or C.