www.johnsonandstarley.co.uk

8. 

FLAME LOSS

 

Should the flame signal be lost 5 times in any 4 minute period then the 
boiler will lockout and an error code will be displayed in the centre of the 
display. Pressing the reset will enable the boiler to relight.

 

If the fault recurs, turn off the boiler and consult a CORGI registered 
installer.

9. 

BOILER OVERHEATING

 

In the event of the boiler overheating the boiler will lockout and an error 

code will be displayed in the centre of the display. Pressing the reset will 

enable the boiler to relight.

 

If the fault recurs, turn off the boiler and consult a CORGI registered 

installer. 

10.  WATER SYSTEM PRESSURE

 

The water system pressure is shown in the bottom right hand of the 

display.

 

If the pressure drops below 1.0 bar it will begin to flash indicating the 

system needs to be topped up by a competent person.

 

If the pressure continues to drop and reaches 0.6 bar, an error code 

will appear in the centre of the display and all heat demands will be 

blocked. This may indicate a leak and the system should be checked 

before being re-pressurised.

11.  CONDENSATE DRAIN

 

The condensate drain must not be modified or blocked.

 

Blockage of the condensate drain caused by debris or freezing, can 

cause the boiler to lockout.

 

If freezing is suspected and the pipe run is accessible, then an attempt 

to free the obstruction by pouring hot water on to the pipe may be 

made. If this fails to remedy the problem, the assistance of a CORGI 

registered installer should be sought.

12.  SERVICE & MAINTENANCE

 

It is recommended that a full maintenance check be carried out 

annually on the appliance. It is also recommended to take out a further 

service agreement on the expiry of the guarantee period.

 

You can obtain further information on this from your gas supplier.

 

The appliance should be checked /serviced by a CORGI registered 

installer. 

 

If you require service on your appliance please contact your local 

installer or gas supplier.

 

On completion of the service the installer should fill in the service 

section at the rear of the BENCHMARK log book. All installers 

registered with CORGI carry an identification card. This card will have 

an ID number which should be recorded in your logbook.

 

If you have any queries regarding your installer you can contact CORGI 

by telephone on 01256 372400.

13.  ESCAPE OF GAS

 

Should a gas leak be suspected contact your gas supplier with out 

delay.

 

Do not search for leak with a naked flame.

14.  CLEANING THE APPLIANCE

 

The appliance casing should only be cleaned with a damp cloth then 

dried. 

 

Do not use abrasive or solvent cleaners.

ER:26

ER:03

1.0

  bar

0.9

 bar

ER:37

Содержание RenoXtra 30C

Страница 1: ...o G For more information see www boilers org uk This is a certification mark Publication No ZZ 1312 May 2008 Product Identification No 87B 074 COMBI SERIES Xtra High Efficiency Combination Boilers www...

Страница 2: ...r Temperature Control P1 Domestic Hot Water Temperature Control P2 Power ON OFF Switch Space for optional programmer Reset Button Pre Heat Button 2 CONTROL PANEL The flip door at the bottom of the boi...

Страница 3: ...y If central heating is not required for any extended period turn the control knob P1 fully anti clockwise to the off position In this position the heating off symbol will be displayed the domestic ho...

Страница 4: ...s or freezing can cause the boiler to lockout If freezing is suspected and the pipe run is accessible then an attempt to free the obstruction by pouring hot water on to the pipe may be made If this fa...

Страница 5: ...if fitted BUTTON DESCRIPTION Time Automatic Run mode selection Prog Programme selection Res Reset clears all settings ON OFF selection in Programme mode Manual override selector in run mode 1h Summer...

Страница 6: ...very Day 1 times 1 2 3 4 5 6 Mon Sat 2 times 1 2 3 4 5 Mon Fri 3 times 6 7 Sat Sun 4 times 1 Monday 5 times 2 Tuesday 6 times 3 Wednesday 7 times 4 Thursday 8 times 5 Friday 9 times 6 Saturday 10 time...

Страница 7: ...off to on 27 CONTINUOUS OPERATION While in the run mode press the key twice to turn the output to permanently on The symbol appears in the display To revert back to timed operation press the until the...

Страница 8: ...Part L of the Building Regulations HOME COMFORT SOLUTIONS Company Details Website Address www johnsonandstarley co uk Email sales johnsonandstarley co uk marketing johnsonandstarley co uk Telephone Nu...

Отзывы: