3.  INITIAL LIGHTING

 

If turning on the boiler for the first time carry out the following steps:

 

 

Check that the electrical supply to the boiler is ON at the  

 

 

 

external isolator.

 

 

Ensure all hot taps are closed.

 

 

Set any remote controls as required.

 

 

Turn the CH and DHW controls to the minimum setting. Switch on  

 

 

the appliance at the on/off switch on the control panel. The boiler  

 

 

will then be in the STANDBY mode.

 

  Check the heating system pressure displayed in the RH lower  

 

 

corner of the display. This should read at least 1.0 bar. A sealed  

 

 

pressurised system must be filled by a competent person.

 

Only operate the boiler when you are sure that the system has been filled 

and pressurised. If you are in any doubt about the boiler being filled with 

water contact your installer.

4.  OPERATION OF CENTRAL HEATING

 

In order to turn on the central heating and adjust the temperature, turn the 

control knob P1 to the desired setting between off and max 82°C.

 

When the control knob is turned the central heating water temperature will 

flash and indicate the new temperature setting.

 

After a delay of 5 seconds the display will revert to a steady display of actual 

central heating water temperature. This will disappear if there is no central 

heating demand.

 

During a central heating demand the radiator symbol and the central heating 

water temperature will be illuminated on the display.

 

If central heating is not required for any extended period turn the control 

knob P1 fully anti-clockwise to the off position. In this position the “heating 

off “ symbol will be displayed, the domestic hot water and frost protection 

will still be active. This is also the “summer mode”. 

5.  OPERATION OF DOMESTIC HOT WATER

 

The domestic hot water temperature is adjustable between 30°C and 65°C 

by the control knob P2.

 

When the control knob is turned the DHW water temperature will flash and 

indicate the new temperature setting.

 

After a delay of 5 seconds the display will revert to a steady display of actual 

DHW temperature. This will disappear if there is no DHW demand.

 

During a DHW demand, the tap symbol and the DHW temperature will be 

illuminated on the display.

6.  PRE-HEAT BUTTON

 

With the pre-heat button selected the boiler is maintained in a hot condition 

to enable a fast response to any DHW demand. When selected, PRE-HEAT 

will be illuminated on the display.

 

If required this can be selected for all year round use, but will be of 

maximum benefit in the summer months, or when there is little or no 

demand for central heating, in which case the boiler would become cold 

without the pre-heat button selected.

 

The pre-heat function has a built-in intelligent function that will turn itself off 

if there is no DHW demand for a 24 hour period. If previously selected, once 

DHW water has been drawn off, the function will automatically re-enable.

7. 

RESET BUTTON

 

Should a fault occur this button can be pressed to reset the controls and 
initiate a new start up sequence.

1.0

  bar

82

˚

C

82

˚

C

65

˚

C

65

˚

C

Содержание RenoXtra 30C

Страница 1: ...o G For more information see www boilers org uk This is a certification mark Publication No ZZ 1312 May 2008 Product Identification No 87B 074 COMBI SERIES Xtra High Efficiency Combination Boilers www...

Страница 2: ...r Temperature Control P1 Domestic Hot Water Temperature Control P2 Power ON OFF Switch Space for optional programmer Reset Button Pre Heat Button 2 CONTROL PANEL The flip door at the bottom of the boi...

Страница 3: ...y If central heating is not required for any extended period turn the control knob P1 fully anti clockwise to the off position In this position the heating off symbol will be displayed the domestic ho...

Страница 4: ...s or freezing can cause the boiler to lockout If freezing is suspected and the pipe run is accessible then an attempt to free the obstruction by pouring hot water on to the pipe may be made If this fa...

Страница 5: ...if fitted BUTTON DESCRIPTION Time Automatic Run mode selection Prog Programme selection Res Reset clears all settings ON OFF selection in Programme mode Manual override selector in run mode 1h Summer...

Страница 6: ...very Day 1 times 1 2 3 4 5 6 Mon Sat 2 times 1 2 3 4 5 Mon Fri 3 times 6 7 Sat Sun 4 times 1 Monday 5 times 2 Tuesday 6 times 3 Wednesday 7 times 4 Thursday 8 times 5 Friday 9 times 6 Saturday 10 time...

Страница 7: ...off to on 27 CONTINUOUS OPERATION While in the run mode press the key twice to turn the output to permanently on The symbol appears in the display To revert back to timed operation press the until the...

Страница 8: ...Part L of the Building Regulations HOME COMFORT SOLUTIONS Company Details Website Address www johnsonandstarley co uk Email sales johnsonandstarley co uk marketing johnsonandstarley co uk Telephone Nu...