1.  Introduction: About Your Lift

The Oxford Standaid 140 is fully assembled, load tested and certified before being packed. 
The packing consists of a strong, purpose built carton and is used for both export and domestic 
markets to ensure the safe arrival of the lift.

Recycling of Packaging:

In an effort to reduce levels of waste and environmental impact, Joerns Healthcare operate a free 
of charge recycling service in the UK. This is specifically for the foam inserts that accompany the 
lift packaging - inside of the carton.

When you are ready to return the foam inserts, simply present them to the Joerns Delivery 
Service Driver on their next visit and they will return them to us for recycling.

Accompanying Documents:

A number of documents are supplied in a wallet packed with each lift and should be retained for 
future reference.

• Test Certificate 

• Dealer Guarantee Card

• User Manual 

• Customer Satisfaction Card

The TeST CerTIfICATe is an important document and is required for your insurance records. 
It is valid for 6 months and once expired, the lift should be inspected and serviced for the 
following six month period. Servicing and periodic LOLer testing can be carried out by your 
supplier. Please ensure your lift is included in their maintenance schedule.

The CE Mark:

The Oxford Standaid carries the Ce mark and comply with the following eC directives:

• Medical Device Directive (93/42/eeC)
• eMC Directive (89/336/eeC) (electrics only)
• Low Voltage Directive (73/23/eeC) (electrics only)

Statement of Intended Use:

The intended use of this lifting device is to transfer an individual from one resting surface to 
another (such as a bed to a chair). Moving a person in a sling over extended distances is not 
recommended.

The Oxford Standaid 140 is suitable for patients in the SITTING position only.

Содержание Oxford Standaid 140

Страница 1: ...User Instruction Manual Oxford Standaid 140 To avoid injury read user manual prior to use...

Страница 2: ...2 Assembly and Commissioning Instructions 4 3 Safety Precautions 6 4 Control Box Handset 8 5 Operating Instructions 9 6 Charging Instructions 11 7 Maintenance Schedule Daily Check List 13 8 Maintenan...

Страница 3: ...ach lift and should be retained for future reference Test Certificate Dealer Guarantee Card User Manual Customer Satisfaction Card The Test Certificate is an important document and is required for you...

Страница 4: ...t the finish from damage WARNING Some of the parts are heavy and will need to be lifted with care You may need assistance with the heavier assemblies 2 Apply the rear castor brakes by pushing the brak...

Страница 5: ...ever Insert screw and fully tighten Fig 1 5 Confirm the legs of the lift open and close satisfactorily by operating the leg adjustment handle in both directions 6 Clip the battery onto the control box...

Страница 6: ...working load of the lift is suitable for the weight of the patient ALWAYS carry out lifting according to the instructions in the user manual NEVER disconnect or bypass a control or safety feature beca...

Страница 7: ...a slope which exceeds 1 12 approximately 5 degrees Joerns Healthcare recommend a second helper is present when moving a patient on a slope DO NOT park a loaded lift on ANY sloping surface DO NOT use e...

Страница 8: ...Oxford Standaid 140 8 English 4 Control Box Handset Battery Level Indicator Emergency Raise Lower Emergency Stop Button Detachable Battery Pack Handset Fig 4 Fig 5...

Страница 9: ...engage as you move off 4 Raising and lowering the boom The movement of the boom is achieved by a powerful electric actuator which is controlled by a simple hand control unit The hand control has two b...

Страница 10: ...r detailed fitting instructions please refer to the user guide supplied with each sling WARNING Joerns Healthcare recommends that slings be checked regularly and particularly before each use for signs...

Страница 11: ...batteries to overcharge a Green Light Indicates main power is on b Yellow Light Indicates battery is charging c Battery will be fully charged when yellow light goes off NOTE Charging will take up to f...

Страница 12: ...e storage period ALWAYS make sure the mains power to the charger is switched off before connecting or disconnecting the power pack NEVER leave the power pack plugged in to the charger with the mains p...

Страница 13: ...recommend the following checks are carried out on a daily basis and before using the lift ENSURE the lift moves freely on its castors ENSURE the legs open and close correctly EXAMINE the sling hooks f...

Страница 14: ...ssis Check the operation of the hand control Check the fuse for correct rating and the fuse holder for firm fitting and possible damage LEG ADJUSTMENT Check the leg linkages are secure and the leg adj...

Страница 15: ...ST The load test should be carried out in accordance with the manufacturer s test procedures It is strongly recommended the testing is carried out by an authorised service dealer CERTIFICATION An auth...

Страница 16: ...Max Height 1585mm Spreader Bar Min Height 1090mm Height At Maximum Reach 1090mm Reach At Minimum Height 240mm Maximum Reach 240mm Turning Radius 1250mm Legs Open External Width 1240mm Internal Width 1...

Страница 17: ...tection Charger Type B Lift Type B Environmental Conditions Outside this environment functionality and safety may be compromised Operating Temperature 5 C to 40 C Relative humidity 20 to 90 30 C not c...

Страница 18: ...equipment as per EN 60601 1 Class 2 equipment The disposal of the charging and control unit should not be mixed with general household waste The disposal of batteries should not be mixed with general...

Страница 19: ...l of our products are commissioned by your dealer and are supported by them for future servicing The dealer or distributor operates the warranty programme so it is important to keep a record of their...

Страница 20: ...ing Inserts o User Handset o ________________________ o Battery Pack Checked for you by ________________________________ 2014 Joerns Healthcare 374 10075 Rev D DCO14 0003 Joerns Healthcare Limited Dra...