background image

15

WARRANTY

     

                                                                  

This product is warranted for a 2-year period for 
home domestic use from the date of the original
purchase. If found to be defective in materials 
or workmanship, the tool or the offending faulty
component will be replaced free of charge with
another of the same item. A small freight charge 
may apply.
The battery and charger only have a 1 year 
manufacturer’s warranty.
The warranty replacement unit is only made 
available by returning the tool to the place of 
purchase with a confirmed register receipt.  
Proof of purchase is essential.
We reserve the right to reject any claim where 
the purchase cannot be verified.
This warranty does not include damage or defects 
to the tool caused by or resulting from abuse, 
accidents, alterations or commercial or business use.

TROUBLESHOOTING

Problem

Probable cause

Suggested remedy

motor will not run

1. Switch in OFF position
2. No electrical power at wall
outlet
3. switch broke down
4. motor broke down
5. defective cable

1. Make sure saw is plugged in and switch is 
pressed
2. Check circuit breaker or fuse at electrical 
panel.
3. replace switch
4. contact service center for Replacing 
motor assembly.
5. replace cable

Motor hums but
cannot
run or runs slowly

1.Low voltage
2.Loose electrical connections
3.Wrong gauge wire or length of
extension cord
4.Shorted or open motor winding

1. Check voltage at wall outlet with voltmeter.
2. Check all electrical connections.
3. Check extension cord chart for proper 
extension cord usage.
4. contact service center for Replacing 
motor assembly.

Flow blows/circuit
breaker trips
repeatedly

1. circuit overloaded
2. Wrong gauge wire or length
of extension cord
3. Motor shorted or seized

1. Disconnect other electrical appliances 
from circuit or operate saw on its own 
branch circuit.
2. Check extension cord chart for proper 
extension cord usage.
3. contact service center for Replacing 
motor assembly.

Содержание JMBMS210G

Страница 1: ...SAFETY AND OPERATING MANUAL 210mm MITRE SAW JMBMS210G...

Страница 2: ...on sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in...

Страница 3: ...lose to the saw blade there is an increased risk of injury from blade contact c The workpiece must be stationary and clamped or held against both the fence and the table Do not feed the workpiece into...

Страница 4: ...own violently o Always use a clamp or a fixture designed to properly support round material such as rods or tubing Rods have a tendency to roll while being cut causing the blade to bite and pull the w...

Страница 5: ...5 1 2 5 3 6 4 7 8 9 10 11 12 13 15 14...

Страница 6: ...Bevel scale See Fig L2 22 Spindle lock See Fig M3 ACCESSORIES Work clamp 1 Dust bag 1 Wrench 1 Support stand 1 Blade 210 1 Extension rail 2 We recommend that you purchase your accessories from the sam...

Страница 7: ...EE FIG A To reduce build up of saw dust and maintain top efficiency of cutting the saw dust collection can be achieved by clipping adjust bag on the dust extraction port 16 A dust bag is provided for...

Страница 8: ...sure that the work clamp securing screws are tightened 4 MOUNTING HOLES SEE FIG E Before use the saw can be fixed to a firm level surface with the 4 mounting bolts not supplied Four holes are provide...

Страница 9: ...osition To release the head ready for operation apply downward pressure and pull out the lock pin a The head will be raised gently to upper position 2 STARTING THE SAW SEE FIG G Depress the trigger sw...

Страница 10: ...o push the saw head down by the handle 6 Continue to move the saw head down smoothly and make the cut exerting only gentle pressure on the downward stroke letting the saw do the work 4 MITER CUT SEEFI...

Страница 11: ...will not damage your power tool If the supply cord of this power tool is damaged it must be replaced by a specially prepared cord available through the service MAINTENANCE WARNING Remove the plug fro...

Страница 12: ...quare Re tighten the locking screws for straight guide SEE FIG K1 K2 Similarly check that the angle of the blade to the face of the rotary table is 90o If necessary adjust the tilt angle of the saw he...

Страница 13: ...lade securing bolt has a left hand thread Remove the blade we recommend the use of a stout glove for this Clean any saw dust and debris from the arbor and saw blade securing flanges To refit the blade...

Страница 14: ...evel lock lever and the slide rod securing knob must all be securely tightened 3 Use the transportation handle to lift the saw Do not lift the saw by the switch handle MAINTENANCE Remove the plug from...

Страница 15: ...ill not run 1 Switch in OFF position 2 No electrical power at wall outlet 3 switch broke down 4 motor broke down 5 defective cable 1 Make sure saw is plugged in and switch is pressed 2 Check circuit b...

Страница 16: ......

Отзывы: