3. REPLACING THE CARBON BRUSHES(SEE FIG. N1-N3)
Check the carbon brushes regularly. If the carbon brushes
are worn down to about 4mm,
replace them with the new set (not supplied). It must be
replaced in pairs.
With a suitable slotted screwdriver turn the cap anti-
clockwise until the carbon brush is released, replace the
brush and make sure that they locate well and are secured
within the brush retainer.
4. MOVING THE SAW
1) When transporting the saw with fixed locations, make
sure that the saw head is locked in the lower position.
2) The rotary table locking knob, the bevel lock lever and the
slide rod securing knob, must all be securely tightened.
3) Use the transportation handle to lift the saw. Do not lift
the saw by the switch handle.
MAINTENANCE
Remove the plug from the socket before carrying out any
adjustment, servicing or maintenance.
There are no user serviceable parts in your power tool. Never
use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth. Always store
your power tool in a dry place. Keep the motor
ventilation slots clean. Keep all working controls free of dust.
Occasionally you may see sparks
through the ventilation slots. This is normal and will not
damage your power tool.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
Содержание JMBMS210G
Страница 1: ...SAFETY AND OPERATING MANUAL 210mm MITRE SAW JMBMS210G...
Страница 5: ...5 1 2 5 3 6 4 7 8 9 10 11 12 13 15 14...
Страница 16: ......