12
in transit. (Ensure power is disconnected while making these
adjustments).
To confirm the 0o rotary table setting, set the rotary table at
0o and tighten the rotary table
locking knob. Check that the angle between the straight guide
and the blade is 90o using a
try square (b, not supplied) as shown in Fig. K1. If the angle
requires adjustment, loosen the
locking screws for straight guide, and align the fence against
the try square.
Re-tighten the locking screws for straight guide. (SEE FIG. K1,
K2)
Similarly, check that the angle of the blade to the face of the
rotary table is 90o. If necessary,
adjust the tilt angle of the saw head at the 90o position:
loosen the bevel lock (20) and adjust the 0° bevel adjustment
screw (c) to bring the saw blade into alignment with the
square. Loosen the head screw (c) holding the pointer of the
bevel scale (21) and adjust the position of the pointer so that
it accurately indicates zero on the scale. Retighten the screw.
Retighten the bevel lock (20) and the 0° bevel adjustment
screw . (SEE FIG. L1, L2)
20
20
b
7
b
21
Fig.H1
Fig.H2
Fig.I1
Fig.I2
Fig.K1
Fig.J2
Fig.J1
Fig.L2
Fig.L1
Fig.K2