Fault106
Array
over-voltage
Inverter
shutdown and
will
restart
automatically
after
malfunction
disappears.
DC
input
voltage
higher than
maximum
input
voltage
of
inverter.
Please
check
maximum
output
voltage
of
array
and
make sure this
voltage is below
inverter
maximum input
voltage.
Fault107
Array
over-current
Inverter
shutdown and
will
restart
automatically
after the fault
disappears.
Input
current
of
inverter
higher than
rated
maximum
value.
If this happen,
please
contact
SUPPLIER.
Fault108
Inverter
AC
output
over
current
Inverter
shutdown and
will
restart
automatically
after the fault
disappears.
1. Power
capacity of
pump motor
is higher
than rated
output.
2. Pump
motor
locked-rot
or, or
damaged.
1.
Please
inspect whether
pump motor is
normal.
2.
Please
inspect whether
pipeline system
is in accordance
with water pump
or not.
3. If this happen