34
module
E
Water level sensor
Optional, for Dry or Overflow protection.
F
GPRS module
Optional, Use for GPRS communication.
6.3 Cable Selection
Please select cable according to the following table.
Table 6-3 Specification of Cables for Electrical Connection
Inverter
Cable range
(
AWG
)
PV+
、
PV-
U
、
V
、
W
PE
U
、
V
、
W
JNP2K2L-V6
14-12
14-12
12
12
JNP3KL-V6
14-12
14-12
12
12
JNP3K7L-V6
14-12
14-12
12
12
JNP4KL-V6
14-12
14-12
12
12
JNP5K5H-V6
14-12
14-12
12
12
JNP7K5H-V6
14-12
14-12
12
12
6.4 Electrical connection on AC input side
Notice
!
It’s forbidden to connect several inverters in parallel to one set of pump!
Danger
!
Ensure that all cables have no charge before electrical operation!
Step 1: Connect the power grid cable with the accessory "power grid input connector" in