StopFreq
Stop frequency (Hz). Setting principle is stop frequency
when minimum flow is output.
F-Limit
Frequency limit, the maximum frequency that the inverter
can output. the default value is "50Hz"or"60Hz"
Load
For selection of load. This figure differs by different
pump.
D-mode
For choose the dry out protection mode. W hen water
sensor is applied, dry protection mode should be set to
detect dry protection. Default is
“DETECT”.
OF-F
For choose over flow warning function. Default is no
overflow warning. If you want to use this function, please
set to “on”. Default is “OFF”.
OF-Time
For choose over flow warning function. Over flow
recovery time, after the warnin g of over flow and inverter
shut down, the duration from shut down to restart.
Default value is 30. Default duration is 30 minutes.
M-Mode
If water output is abnormal, and caused by reversed
motor phase sequence, you can try to reset this model
from
“REV” to “FWD”. Default is “FWD”.
Facc
When the economic mode is selected, when the
operating frequency is lower than the access frequency,
the power grid is connected to ensure the maximum
power operation of the inverter. (This parameter setting
value must be greater than stop frequency)
The factory
default is 35Hz.
Pexit
During economic mode, when the solar power is higher
than the exit power, the power grid exit ensures that the