2.2 Display Functions
Start the Measuring System
NOTE! Make sure the telescoping measuring arm is
completely collapsed.
Start the display by pressing shortly on the
button. A
digital number 900 (900 mm) will appear in the display window
representing the start length of the tool (from the center of
the chassis attachment to the center of the measuring tip).
Important!
If display does not read 900 – switch off by holding down the
button for a few seconds and restart following the above
procedure.
Normal Position
This is the automatic position on the measuring tool after
starting it. Working area of the tool is now
900-2650 mm
.
Comparative Measuring
The digital reading can be reset for quick comparative checks
during normal length measuring operations by briefly pushing
the
button to select 0 mm. From this point any change in
length will register plus or minus in 1 mm gradients. Additional
comparative checking is possible by repeating the above
procedure at any time during comparative checking.
To resume normal length measuring i.e. 900-2650 mm settings,
simply depress the button
< 1 second.