background image

 

10 

Erforderliche Parameter fehlen oder sind falsch.

 

EG Konformitätserklärung (EC Declaration of Conformity)

 

 

 

 

Hiermit erklären wir, 
We her

ebyewith

 

declare, 

 

Johannes J. Matthies GmbH & Co. KG 
Hammerbrookstr. 97, Hamburg, Germany

 

 

dass die nachfolgend bezeichnete Maschine aufgrund ihrer Konzipierung und Bauart sowie in der von uns in Ver- 
kehr  gebrachten Ausführung  den  einschlägigen  grundlegenden  Sicherheits-  und  Gesundheitsanforderungen  der 
EG-Richtlinien entspricht. 
that the following machine

, as brought into circulation by us,

 complies with the appropriate basic safety and health 

requirements of the EC Directive based on

 

its design and type

, as brought into circulation by us

 

Bei einer nicht mit uns abgestimmten Änderung der Maschine verliert diese Erklärung ihre Gültigkeit. 
In case of alteration of the machine

,

 not agreed upon by us, this declaration will lose its validity. 

 

Bezeichnung der Maschine: 
Machine Description: 

Motorrad Hebebühne 
Motorcycle 

Bike LiftLifting Platform

 

 

Maschinentyp: 
Machine Type: 

JMP Lux 300 EH

 

Handelsmarke: 
Trade name 

JMP 

 

Maschinen-Nr.: 
Serial Number 

 

Einschlägige EG-Richtlinien: 
Applicable EC Directives: 

EG-Maschinenrichtlinie 2006/42/EC

 

EC Machinery Directive: 2006/42/EC 

EG-Niederspannungsrichtlinie 2006/95/EG

 

EC

-

 Low 

Vv

oltage 

Dd

irective 

2006/95/EC 

 

Angewandte harmonisierte 
Normen: 
Applicable Harmoni

sz

ed 

Standards: 

EN 1493:2010 
EN 60204-1:2006/A1:2009

 

Herstellerunterschrift/Datum: 
Authori

zs

ed Signature/Date: 

 

 

Angaben zum Unterzeichner: 
Title of Signatory:

.05.01.2016  ………………………………………………........................................

Dokumentationsbevollmächtiger

 

Stefan Onken (Product Manager)

 

Documentation representative

 

Hammerbrookstr. 97, 20097 Hamburg 

 

Diese Konformitätserklärung wurde vom TÜV Product Service vorbereitet. Ein Muster dieses Produktes hat die 
Anforde-

 

rungen  der  Konformitätsprüfung  erfüllt.  Diese Prüfung  wurde  beim TÜV  Product  Service  aufgrund  der 

zutreffenden  Vor-

 

schriften der genannten Richtlinien durchgeführt. 

This Declaration of Conformity has been prepared by TÜV Product Service. A specimen of this product meets the 
require-

 

ments of conformity test carried out by TÜV Product Service according with the applicable standards under 

the 

statmention

ed

 

directives. 

 

TÜV Product Service Prüfbericht Nr./TÜV Product Service 

Rr

eport 

Rr

eference 

Nn

o.:

 

70.520.15.124.01-00 

Date/Datum Jan. 18, 2016 
Revision 1 

Содержание Lux 300 EH

Страница 1: ... falsch EN Motorcycle Lifting Platform JMP Lux 300 EH DK Motorcykle Lift JMP Lux 300 EH PL Podośnik motocyklowy JMP Lux 300 EH ES Plataforma moto JMP Lux 300 EH IT Ponte sollevatore per motociclette JMP Lux 300 EH Johannes J Matthies GmbH Co KG Hammerbrookstr 97 20097 Hamburg Deutschland www jmproducts eu info jmproducts eu JM No 674 00 91 ...

Страница 2: ... EG Konformitätserklärung EC Declaration of Conformity 10 Contact partners Manufacturer Johannes J Matthies GmbH Co KG Hammerbrookstr 97 20097 Hamburg Tel 49 0 40 23721 0 Fax 49 0 40 2 37 21 363 Internet http www matthies de Email info matthies de Service and Repairs Matthias Workshop Service Hammerbrookstr 78 20097 Hamburg Tel 040 73 44 17 120 Fax 0 40 73 44 17 199 Internet http www matthies de E...

Страница 3: ...stable and securely fastened This may take place either with optional wheel support an optional assembly stand or via optional lashing Raise the platform slightly and make sure that the vehicle stands correctly and safely 1 9 When lifting and lowering the lifting platform the operator must maintain visual contact with the lifting platform 1 10 People may not loiter on the lifting platform at any t...

Страница 4: ... platform may only be lifted up short term to perform maintenance or repairs 5 4 The lifting platform may only be operated by persons who have received intensive training in the operation and safety instructions of the lifting platform The following uses are not permitted 5 5 Outdoor use 5 6 Lifting of vehicles or other devices which either exceed the permissible carrying weight of 300 kg or have ...

Страница 5: ...for damage 6 5 Electrical connections may only be installed by a qualified engineer During installation it is absolutely necessary to ensure a secure connection which is protected against mechanical burdens 7 Operation The lifting platform may only be operated with knowledge of the full content of the user manual Therefore please make absolutely sure that this manual is read in full before the lif...

Страница 6: ... catch must reactivate independently upon complete shutdown of the lifting platform o When fully raising the ramp the pump must be electrically deactivated via the built in limit switches see spare parts 33 and 34 under Point 10 Clean lifting platform Check limit switch see spare parts 33 and 34 under Point 10 Check for oil leakage If any of these safety measures should not function or if you are ...

Страница 7: ...ally to the highest possible position Remove the plug from the oil tank This must be almost full If necessary add HLP 10 JM No 558 9 70 The lifting platform cannot be lowered any more 1 Check if the safety catch is released and if this allows the lifting platform to be lowered 2 Is the lifting platform mechanically blocked Check the lifting platform for mechanical obstructions 3 Is there sufficien...

Страница 8: ... may only be performed by qualified technicians When replacing parts it is necessary to ensure that the only spare parts used are ones which fully match the original components in terms of quality and design If necessary please contact the Matthies Workshop Service or your sales partner to discuss the further steps to be taken ...

Страница 9: ...7 Erforderliche Parameter fehlen oder sind falsch Lifting platforms spare parts If you have any questions please contact the Matthies Workshop Service ...

Страница 10: ... connection Pump Transformer Pump control Magnet shutdown SB0 Pushbutton for emergency shutdown FU Fuse SB1 Pushbutton for lifting KM Network connection SB 2 Pushbutton for sinking YV Pressure relief valve SQ Upper limit switch TC Transformer VC AC DC converter MQ Solenoid ...

Страница 11: ...9 Erforderliche Parameter fehlen oder sind falsch 12 Hydraulics 1 Cylinder 6 Pump 2 Check valve 7 Pump motor 3 Overflow valve 8 Filter 4 Lowering valve 9 Oil tank 5 Throttle valve ...

Страница 12: ...me JMP Maschinen Nr Serial Number Einschlägige EG Richtlinien Applicable EC Directives EG Maschinenrichtlinie 2006 42 EC EC Machinery Directive 2006 42 EC EG Niederspannungsrichtlinie 2006 95 EG EC Low Vvoltage Ddirective 2006 95 EC Angewandte harmonisierte Normen Applicable Harmoniszed Standards EN 1493 2010 EN 60204 1 2006 A1 2009 Herstellerunterschrift Datum Authorizsed Signature Date Angaben z...

Отзывы: