5
Erforderliche Parameter fehlen oder sind falsch.
9. Fault diagnosis
The lifting platform cannot be lifted any more!
1.
Has the additional weight of 300 kg been exceeded?
2.
Has the lifting platform been correctly connected? Is there a supply voltage? Is it possible that the fuse has
blown?
3.
Has the circuit breaker of the lifting platform blown? Make sure that the lifting platform is separated from
the voltage network; check the fuses
4.
Is there sufficient hydraulic fluid available? Make sure that the lifting platform is separated from the voltage
network. Raise the platform manually to the highest possible position. Remove the plug from the oil tank.
This must be almost full. If necessary, add HLP 10, JM-No. 558.9.70.
The lifting platform cannot be lowered any more!
1.
Check if the safety catch is released and if this allows the lifting platform to be lowered.
2.
Is the lifting platform mechanically blocked? Check the lifting platform for mechanical obstructions
3.
Is there sufficient hydraulic fluid available? Make sure that the lifting platform
is separated from the voltage network. Raise the platform manually to the highest possible position.
Remove the plug from the oil tank. This must be almost full. If necessary, add HLP 10, JM-No. 558.9.70.
Should these steps not prove successful, please contact the Matthies Workshop Service or your sales partner.
Stoppers