6. Installation
6.1.
The installation and commissioning of the “JMP Lux 300 EH” lifting platform may only be performed by
qualified persons.
6.2.
The “JMP Lux 300 EH” lifting platform may only be installed and operated in dry interiors. A flat surface of
at least 250 x 200 cm is required for installation. In order to guarantee a secure footing for the lifting
platform and the mechanic working on it, the floor should be even. Otherwise, the platform must be fixed
to the ground with ground anchors.
6.3.
It is expressly forbidden to use the lifting platform in the following areas:
a)
Areas with an explosion or fire risk
b)
Areas which are wet or humid
c)
Exterior areas
6.4.
Electrical connections: An electrical connection of 230V/16A/50 Hz is ne
cessary for the “JMP Lux 300
EH” lifting platform. The “JMP Lux 300 EH” lifting platform is delivered to you in a preassembled state.
Please remove the lifting platform from the shipping container and perform a thorough visual inspection
of the lifting platform in order to detect any transport damage. Please also check all electrical and
hydraulic connections for damage.
6.5.
Electrical connections may only be installed by a qualified engineer. During installation, it is absolutely
necessary to ensure a secure connection which is protected against mechanical burdens.
7. Operation
The lifting platform may only be operated with knowledge of the full content of the user
manual. Therefore, please make absolutely sure that this manual is read in full before the
lifting platform is first commissioned!
The lifting platform may only be operated by duly qualified persons. Please note that any misuse can lead to
serious accidents!
7.1.
Raising / lowering
The lifting platform is controlled by a wired remote control system. The lifting platform will be raised / lowered
for the duration that the “UP ” / “DOWN ” button is pressed,.
As soon as the respective endpoint of the lifting platform has been reached, the
control system will be automatically switched off.
7.2.
Emergency switch
The lifting / lowering of the lifting platform can be interrupted with the emergency switch at any time. For
this, the emergency switch must be pressed down. To unlock it again, the switch must be turned to the
right.
7.3.
Safety latch
In the unlikely event of failure of the hydraulic unit, the lifting platform must be equipped
with a safety latch which, first and foremost, protects against an uncontrolled lowering of
the platform.
Emergency
switch