HYDRAULIC SYSTEM
3
3
3.5 Drive manifold
1
: Solenoid valve 4-way, 3-position (floating center
spool).
F
UNCTION
: Selection of the drive direction (FWD /
REV).
2
: Accumulator
See § 3.6.
Torque value for the 4 bolts securing the solenoid
valve : 9 N.m
3.6 Membrane accumulator
F
UNCTION
: Enables storage of a volume of oil destined
to the make up flow for the wheel motors during
reversal of the drive direction.
!
DANGER
Technical characteristics :
Never loosen the top seal screw.
Manifold schematic :
REV
Cap
Pressure
reservoir
Top seal
screw
Membrane
Obturator
Port
Inflating pressure
0,5 MPa (5 bar)
Gaz
Nitrogen
Maximum pressure
21 MPa (210 bar)
Nominal volume
0,16 litre
Port size
Ø 1/2" BSPP
FWD
MAV : FWD
MAR : REV