MACHINE CONTROLS
Section 1
Page 1-10
1001206597
METRO-LED
OPTIONAL CONTROL PANEL
METRO-LED MODULE
1. Lighting tower control module, controls
engine/genset and tower lights.
2. Mast function enable switch. Toggle
“up” and hold before toggling other
mast control switches
3. Mast raise/lower toggle switch.
Toggle switch “up” to raise mast.
Toggle switch “down” lower mast.
Note: Switch centre position is “off”.
4. Lighthead tilt toggle switch. Tilts light-
head up to 40° from the horizontal.
Note: Switch centre position is off.
5. Lighthead rotate toggle switch. Rotates
lighthead ±58° of the trailer centre-line.
Note: Switch centre position is “off”
RELEASE EMERGENCY-STOP BUTTON,
BEFORE OPERATING THE CONTROLLER.
OPTIONAL METRO-LED MODULE
AUTO-START INSTRUCTIONS
1. Complete all lighting tower operating
safety checks.
2. Switch battery and engine starter
isolators to “on” and the emergency
stop button is released.
3. Press the Auto button on the LED
controller to show the AUTO MODE
SELECT screen.
4. Use the UP and DOWN ARROWS to
scroll to 01 AUTO TIMER MODE.
5. Press the MENU/CONFIRM button.
6. Scroll to 03 TIMER SET using the UP
or DOWN arrows.
7. Press MENU/CONFIRM to open the
Timer Running Action screen.
3
2
5
1
4
1
2
3
4
5