- 18

 

-

 

 

2)

Half-cut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 8: PV module installed at long and short side with Clamp fitting method 

Module 

type 

Cell type 

Cell 

quantity 

Dimension(mm) 

A*B 

Frame 

Group 2

 

6 inch Poly 

6*20 

1665*992 & 1684*1002 

50

 

240

 

400

 

420 

40*35 & 35*35 

Group 5 

6 inch Poly 

6*24 

1987*992 & 2000*992 & 2008*1002  50

 

240

 

400

 

420 

40*35 & 35*35 

Group 8 

6 inch Mono 

6*20 

1665*992 & 1684*1002 

50 

240 

400 

480 

40*35 

Group 11 

6 inch Mono 

6*24 

1987*992 & 2000*992 & 2008*1002  50 

240 

400 

480 

40*35 

Table 8: Mechanical dimensions when modules installed at long and short sides with Clamp fitting method 

3. Wiring and connection 

a) Before this procedure, please read the operation instructions of the PV system carefully. 

Make  wiring  by  Multi-connecting  cables  between  the  PV  modules  in  series  or  parallel 
connection,  which  is  determined  by  user‟s  configuration  requirement  for  system  power, 

current and voltage. 

b) PV  modules  connected  in  series  should  have  similar  current,  and  modules  must  not  be 

connected  together  to  create  a  voltage  higher  than  the  permitted  system  voltage.  The 

maximum  number  of  modules  in  series  depends  on  system  design,  the  type  of  inverter 

used and environmental conditions. 

c) The maximum fuse rating value in an array string can be found on the product label or in 

the  product  datasheet.  The  fuse  rating  value  is  also  corresponding  to  the  maximum 

reverse current that a module can withstand, i.e. when one string is in shade then the other 

parallel  strings  of modules  will  be  loaded by  the  shaded  string  and  the  current  will  pass 

Содержание JKM***M-60

Страница 1: ...JinkoSolar Photovoltaic Module User Manual UL1703 ...

Страница 2: ...stallation introduction 2 2 1 Climate condition 2 2 2 Site selection 2 3 1 Fixation with screws 2 3 2 Fixation with clamps 2 2 3 Tilt angle selection 3 Wiring and connection 4 Maintenance and care 5 Electrical specification 6 Disclaimer of Liability 29 29 Edition 10 2018 41 7 Contact us 8 15 16 2 3 3 Fixation with clamps at short sides of the frames 2 3 4 Fixation with clamps at the long short sid...

Страница 3: ...0 Plus JKMxxxPP 60 J4 JKMxxxPP 60B J4 JKMxxxPP 60 W JKMxxxPP 60B W xxx 200 300 in increment of 5 Group 2 JKMxxxPP 60H JKMxxxPP 60H J4 JKMxxxPP 60HB xxx 200 310 in increment of 5 Group 3 JKMS xxxP 60 JKMSxxxP 60 J4 JKMSxxxP 60B JKMSxxxP 60B J4 JKMSxxxPP 60 JKMSxxxPP 60 J4 JKMSxxxPP 60B J4 JKMSxxxPP 60B JKMSxxxPP 60 W JKMSxxxPP 60B W xxx 200 275 in increment of 5 Group 4 JKMxxxP 72 JKMxxxP 72B JKMxx...

Страница 4: ...JKMxxxM 72B J4 JKMxxxM 72 W JKMxxxM 72B W xxx 250 400 in increment of 5 JKMxxxM 72L xxx 370 400 in increment of 5 Group 11 JKMxxxM 72H JKMxxxM 72HB xxx 250 410 in increment of 5 JKMxxxM 72HL xxx 370 410 in increment of 5 Group 12 JKMSxxxM 72 JKMSxxxM 72 J4 JKMSxxxM 72 W xxx 250 355 in increment of 5 Notes B module with black back sheet J4 the eagle black series module PP the eagle series module Pl...

Страница 5: ...Class A Fire Rating in America Module model Specific construction Marking Group 1 Group 12 Superstrate 3 2 4 0 mm thick EVA 0 25 0 65 mm thick Substrate 0 3 mm 0 451 mm thick Frame Types 40mm by 20mm or 40mm by 35mm or 700 0218 Module Fire Performance Type 1 1 3 Warnings PV modules generate DC electrical energy when exposed to sunlight or other light sources Active parts of module such as terminal...

Страница 6: ... module complies with the requirements of UL 1703 The installation work of the PV array can only be done under the protection of sun sheltering covers or sunshades and only qualified person can install or perform maintenance work on this module Follow the battery manufacture s recommendations if batteries are used with modules Do not use this module to replace or partly replace roofs and walls of ...

Страница 7: ...prohibited and there is a risk of damage to the module and cause injury for you Only PV modules with the same cell size should be connected in series During transporting modules please attempt to minimize shock or vibration to the module as this may damage the module or lead to cell micro cracks During all transportation situations never drop the module from a vehicle house or hands This will dama...

Страница 8: ...h other connectors Connector model name Allowable mating connector model name TL Cable01F TL Cable01M PV JK00MO PV JK00MO UTXCFA4A UTXCMA4A Helios H4 Assembled Helios H4 Assembled PV JK03M 1 PV JK03M 1 PV KST4 6II UR PV KBT4 6II UR PV JK03M 2 PV JK03M 2 PV JK03M F xy PV JK03M M xy PV KBT4 EVO2 6II UR PV KST4 EVO2 6II UR Insert module connectors fully and correctly An audible click sound should be ...

Страница 9: ...system design 2 2 2 Site selection In most applications Jinko Solar PV modules should be installed in a location where they will receive maximum sunlight throughout the year In the Northern Hemisphere the module should typically face south and in the Southern Hemisphere the modules should typically face north Modules facing 30 degrees away from true South or North will lose approximately 10 to 15 ...

Страница 10: ...ystems with batteries where the PV modules are attached to a permanent structure the tilt angle of the PV modules should be selected to optimize the performance based on seasonal load and sunlight In general if the PV output is adequate when irradiance is low e g winter then the angle chosen should be adequate during the rest of the year For grid connected installations where the PV modules are at...

Страница 11: ... conformance with the grounding device manufacturer s instructions 5 Common hardware items such as nuts bolts star washers lock washers and the like have not been evaluated for electrical conductivity or for use as grounding devices and should be used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices...

Страница 12: ...e Mounting hardware configuration Hardware Material Size Number provided Group 1 Group 12 Bolt Stainless steel M8 4 Spring washer Stainless steel M8 8 Nut Stainless steel M8 4 Alternate Mounting Method bolting mounting method using the 12provided mounting holes in the frame with a torque of 16 20Nm The following stainless steel mounting hardware should be included in the installation instructions ...

Страница 13: ...Rev C 11 ...

Страница 14: ...products only allow using clamps at long side of frames The module clamps should not come into contact with the front glass and must not deform the frame Be sure to avoid shadowing effects from the module clamps The module frame is not to be modified under any circumstances When choosing this type of clamp mounting ...

Страница 15: ...w illustration the mounting place distance is suggested bigger than J and less than K as showed below 1 Half cut Figure 3 half cut installed at long side with Clamp fitting method Module type Cell type Cell quantity Dimension mm A B J K Group 2 6 inch Poly 6 20 1665 992 1684 1002 400 420 Group 5 6 inch Poly 6 24 1987 992 2000 992 2008 1002 400 480 Group 8 6 inch Mono 6 20 1665 992 1684 1002 400 42...

Страница 16: ... 42 mm Aluminum alloy End Clamp 35 mm thickness 41 5 x 50 x 40 mm Middle Clamp 42 x 50 x 28 mm Table 3 above The specification material of clamp Module type Cell type Cell quantity Dimension mm A B J K Frame Group 1 Group 3 Poly 6 10 1650 992 1665 1002 400 420 40 35 35 35 Group 4 Group 6 Poly 6 12 1956 992 1979 1002 400 480 40 35 Group 7 Group 9 Mono 6 10 1650 992 1665 1002 400 420 40 35 35 35 Gro...

Страница 17: ...uirements for mounting with clamps please refer to the instructions in 2 3 2 and find detailed mounting information in the below Figure 5 6 The mounting place distance is suggested bigger than J and less than K as shown below 1 Half cut Figure 5 above PV module installed at short side with Clamp fitting method Module type Cell type Cell quantity Dimension mm A B J K Frame Group 2 6 inch Poly 6 20 ...

Страница 18: ...5 35 Group 4 6 6 inch Poly 6 12 1956 992 1979 1002 50 240 40 35 Group 10 12 6 inch Mono 6 12 1956 992 1979 1002 50 240 40 35 Table 6 above Mechanical dimensions when modules installed at short side with Clamp fitting method 2 3 4 Fixation with clamps at the long short sides this method has not been UL 1703 certified When installing modules using clamps on the long side short side of the frame the ...

Страница 19: ...and less than N for long sides as shown below 1 Normal PV module Figure 7 PV module installed at long and short side with Clamp fitting method Module type Cell type Cell quantity Dimension mm A B J K M N Frame Group 1 3 6 inch Poly 6 10 1650 992 1665 1002 50 240 400 420 40 35 35 35 Group 7 9 6 inch Mono 6 10 1650 992 1665 1002 50 240 400 420 40 35 35 35 Group 4 6 6 inch Poly 6 12 1956 992 1979 100...

Страница 20: ...e PV system carefully Make wiring by Multi connecting cables between the PV modules in series or parallel connection which is determined by user s configuration requirement for system power current and voltage b PV modules connected in series should have similar current and modules must not be connected together to create a voltage higher than the permitted system voltage The maximum number of mod...

Страница 21: ...onductor to the module frame using the hole and hardware provided Note that a stainless steel bolt is used between the ground wire and module frameas illustrated in following figure This washer is used to avoid corrosion due to dissimilar metals Tighten the screw securely It is recommended that the applied torque is 2 3 to 2 8Nm Module Mounting hardware configuration Hardware Material Size Number ...

Страница 22: ...o consideration before designing the wiring layout m Jinko Solar requires the negative grounding of the inverter when a system is installed with standard non Eagle line PV solar modules Alternatively a charge equalizing device may be used to mitigate the effects of the Potential Induced Degradation PID phenomenon that can occur in specific environments that the array is installed in 4 Maintenance ...

Страница 23: ...nergy output 5 Electrical specification The module electrical ratings are measured under Standard Test Conditions which are 1000W m2 irradiance with AM 1 5 spectrum and 25 deg 77 F ambient temperature The module might produce more or less voltage or current than rated value in uncertainty condition Tables below are electrical characteristics of PV products at STC and the tolerance of Isc Voc Vmp a...

Страница 24: ...1 36 3 36 6 36 8 37 0 37 3 37 5 37 7 Short circuit Current Isc A 8 09 8 18 8 25 8 31 8 41 8 48 8 56 8 65 8 71 8 76 8 85 Maximum system Voltage 1000VDC Dimensions Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Large cell PV module 1665x1002x40mm 65 55 39 45 x1 57 inch Half cut PV module 1665x992x40mm 65 55 39 05 x1 57 inch Large cell Half cut PV module 1684x1002x40mm 66 30 39 45 x1 57 inch L...

Страница 25: ...rcuit Current Isc A 8 92 8 98 9 03 9 09 9 15 9 20 9 26 9 32 9 37 9 43 9 49 9 59 Maximum system Voltage 1000VDC Dimensions Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Large cell PV module 1665x1002x40mm 65 55 39 45 x1 57 inch Half cut PV module 1665x992x40mm 65 55 39 05 x1 57 inch Large cell Half cut PV module 1684x1002x40mm 66 30 39 45 x1 57 inch Large cell PV module 1665x1002x35mm 65 55...

Страница 26: ...Power Current Imp A 7 46 7 60 7 73 7 86 7 98 8 12 8 23 8 36 Open circuit Voltage Voc V 33 5 33 7 34 0 34 3 34 5 34 8 35 0 35 2 Short circuit Current Isc A 8 53 8 61 8 68 8 75 8 85 8 92 9 01 9 10 Maximum system Voltage 1000VDC Dimensions Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Large cell PV module 1665x1002x40mm 65 55 39 45 x1 57 inch Large cell PV module 1665x1002x35mm 65 55 39 45 x1...

Страница 27: ...06 Open circuit Voltage Voc V 35 4 35 6 35 8 36 1 36 2 36 7 36 9 37 2 Short circuit Current Isc A 9 17 9 23 9 32 9 39 9 45 9 51 9 57 9 58 Maximum system Voltage 1000VDC Dimensions Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Large cell PV module 1665x1002x40mm 65 55 39 45 x1 57 inch Large cell PV module 1665x1002x35mm 65 55 39 45 x1 38 inch Normal PV module 1650x992x35mm 64 97 39 05 x1 38...

Страница 28: ...7 49 7 59 7 71 7 81 7 93 8 03 8 11 8 15 8 20 8 30 Open circuit Voltage Voc V 43 5 43 7 43 9 44 1 44 2 44 4 44 5 44 7 44 9 45 1 45 3 45 6 Short circuit Current Isc A 8 05 8 18 8 26 8 33 8 43 8 49 8 58 8 61 8 69 8 76 8 84 8 91 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 57 inch Half cut PV module 1...

Страница 29: ...pen circuit Voltage Voc V 45 9 46 2 46 4 46 7 46 9 47 2 47 5 47 8 48 48 2 48 5 48 8 49 1 Short circuit Current Isc A 8 96 9 01 9 05 9 1 9 14 9 18 9 22 9 29 9 36 9 43 9 51 9 58 9 63 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 57 inch Half cut PV module 1987x992x40mm 78 23 39 05 x1 57 inch Large ce...

Страница 30: ...ge Vmp V 32 5 32 8 33 0 33 2 33 3 33 4 33 5 33 7 Maximum Power Current Imp A 7 69 7 78 7 88 7 99 8 12 8 22 8 35 8 45 Open circuit Voltage Voc V 41 3 41 5 41 7 41 9 42 0 42 2 42 3 42 5 Short circuit Current Isc A 8 52 8 61 8 70 8 77 8 87 8 94 9 03 9 06 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 5...

Страница 31: ...wer Current Imp A 8 54 8 58 8 63 8 74 8 82 8 93 9 01 9 12 9 20 Open circuit Voltage Voc V 42 7 42 8 43 0 43 3 43 6 43 9 44 1 44 5 44 7 Short circuit Current Isc A 9 15 9 22 9 31 9 38 9 43 9 48 9 53 9 55 9 57 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 57 inch Maximum series overcurrent protective...

Страница 32: ... 8 06 8 14 8 20 8 28 8 42 8 50 Open circuit Voltage Voc V 35 3 35 5 35 8 36 1 36 3 36 6 36 8 37 0 37 3 37 5 37 7 38 0 37 9 38 2 Short circuit Current Isc A 8 09 8 18 8 25 8 31 8 41 8 48 8 56 8 65 8 71 8 76 8 85 8 96 9 10 9 19 Maximum system Voltage 1000VDC Dimensions Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Half cut PV module 1665x992x40mm 65 55 39 05 x1 57 inch Large cell PV module 1...

Страница 33: ... 38 4 38 5 38 6 38 7 39 5 39 7 40 1 40 3 40 5 40 7 40 9 41 1 41 3 41 5 41 7 Short circui t Current Isc A 9 28 9 40 9 49 9 51 9 55 9 61 9 72 9 83 9 92 10 0 4 10 1 5 10 2 10 3 1 10 3 6 10 5 5 Maximum system Voltage 1000VDC Dimension s Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Half cut PV module 1665x992x40mm 65 55 39 05 x1 57 inch Large cell PV module 1665x1002x35mm 65 55 39 45 x1 38 inc...

Страница 34: ...wer Current Imp A 7 09 7 22 7 34 7 47 7 59 7 71 7 82 7 94 8 06 8 14 Open circuit Voltage Voc V 35 3 35 5 35 8 36 1 36 3 36 6 36 8 37 0 37 3 37 5 Short circuit Current Isc A 8 09 8 18 8 25 8 31 8 41 8 48 8 56 8 65 8 71 8 76 Maximum system Voltage 1000VDC Dimensions Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Large cell PV module 1665x1002x40mm 65 55 39 45 x1 57 inch Large cell PV module 1...

Страница 35: ... 9 02 9 10 Open circuit Voltage Voc V 37 7 37 9 38 0 38 2 38 4 38 5 38 6 38 7 39 5 39 7 Short circuit Current Isc A 8 85 8 92 9 10 9 19 9 28 9 40 9 49 9 51 9 55 9 61 Maximum system Voltage 1000VDC Dimensions Normal PV module 1650x992x40mm 64 97 39 05 x1 57 inch Large cell PV module 1665x1002x40mm 65 55 39 45 x1 57 inch Large cell PV module 1665x1002x35mm 65 55 39 45 x1 38 inch Normal PV module 165...

Страница 36: ... 7 37 7 44 7 52 7 62 7 71 7 81 7 90 8 02 8 11 8 20 8 29 Open circuit Voltage Voc V 43 4 43 6 43 9 44 1 44 4 44 6 44 8 45 0 45 2 45 3 45 5 45 7 45 9 Short circuit Current Isc A 7 84 7 92 7 99 8 07 8 15 8 23 8 32 8 40 8 47 8 55 8 64 8 72 8 80 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 57 inch Half...

Страница 37: ...Open circuit Voltage Voc V 46 1 46 3 46 5 46 7 46 9 47 1 47 3 47 5 47 8 48 0 48 2 48 5 48 7 48 9 Short circuit Current Isc A 8 87 8 95 9 03 9 11 9 18 9 24 9 31 9 38 9 45 9 51 9 57 9 61 9 68 9 75 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 57 inch Half cut PV module 1987x992x40mm 78 23 39 05 x1 57...

Страница 38: ...9 3 49 5 49 8 50 1 50 4 Short circuit Current Isc A 9 92 10 12 10 23 10 36 10 48 10 60 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 57 inch Half cut PV module 1987x992x40mm 78 23 39 05 x1 57 inch Large cell Half cut PV module 2008x1002x40mm 79 06 39 45 x1 57 inch Half cut PV module 2000x992x40mm 7...

Страница 39: ... 3 35 6 35 9 36 1 36 3 36 5 36 7 36 8 37 0 37 2 Maximum Power Current Imp A 7 18 7 29 7 37 7 44 7 52 7 62 7 71 7 81 7 90 8 02 8 11 8 20 Open circuit Voltage Voc V 43 4 43 6 43 9 44 1 44 4 44 6 44 8 45 0 45 2 45 3 45 5 45 7 Short circuit Current Isc A 7 84 7 92 7 99 8 07 8 15 8 23 8 32 8 40 8 47 8 55 8 64 8 72 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 5...

Страница 40: ... Current Imp A 8 29 8 38 8 47 8 55 8 64 8 72 8 79 8 87 8 94 9 04 Open circuit Voltage Voc V 45 9 46 1 46 3 46 5 46 7 46 9 47 1 47 3 47 5 47 8 Short circuit Current Isc A 8 80 8 87 8 95 9 03 9 11 9 18 9 24 9 31 9 38 9 45 Maximum system Voltage 1000VDC Dimensions Normal PV module 1956x992x40mm 77 01 39 05 x1 57 inch Large cell PV module 1979x1002x40mm 77 91 39 45 x1 57 inch Maximum series overcurren...

Страница 41: ...sumed by Jinko for any infringement of patents or other rights of third parties which may result from use of the PV product NO license is granted by implication or otherwise under any patent or patent rights The information in this manual is based on Jinko s knowledge and experience and is believed to be reliable but such information including product specification without limitations and suggesti...

Страница 42: ..._______________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ ...

Страница 43: ...34100 Tel 86 793 8588188 Fax 86 793 8461152 Jinko solar Import and Export co LTD Xuri District Shangrao Economic Development Zone Jiangxi Province China Postcode 334100 Tel 86 793 8618987 Fax 86 793 8461152 Customer Service cs jinkosolar com Jinko Solar USA 495 Market Street Suite 2200 San Francisco CA 94105 Tel 415 402 0502 Fax 415 402 0703 us jinkosolar com Jinko Solar Canada Co Ltd Suite 703 10...

Страница 44: ...ent Zone Jiangxi Province China 334100 Tel 86 793 858 8188 Fax 86 793 846 1152 Jiangxi Manufacture Base No 58 Yuanxi Road Haining Yuanhua Industrial Park Zhejiang Province China 314416 Tel 86 573 8798 5678 Fax 86 573 8787 1070 Zhejiang Manufacture Base Jinko Building 99 Shouyang Road Jingan District Shanghai China 200027 Tel 86 21 5183 8777 Fax 86 21 5180 8600 ...

Отзывы: