Rev. C
- 15
-
Clamp type
Dimension(mm)
Q
O
R
P
Middle Clamp
13.5
0.5~2
15
2.5
Table 4 above: Mechanical dimensions when modules installed with mid Clamp
2.3.3 Fixation with clamps at short sides of the frames (this method has not been UL
1703 certified)
When installing modules using clamps on the short side of the frame, the products in Table 5
& 6 and the clamp in Table 3 & 4 are applicable. The fixation with clamps at short sides of the
frames
can‟t be used unless the fixation is UL certified with Jinko modules.
The considerations and requirements for mounting with clamps, please refer to the
instructions in 2.3.2, and find detailed mounting information in the below Figure 5 & 6. The
mounting place distance is suggested bigger than J and less than K, as shown below.
1)Half-cut
Figure 5 above: PV module installed at short side with Clamp fitting method
Module
type
Cell type
Cell
quantity
Dimension(mm)
A*B
J
K
Frame
Group 2
6 inch Poly
6*20
1665*992 & 1684*1002
50
240
40*35 & 35*35
Group 5
6 inch Poly
6*24
1987*992 & 2000*992 & 2008*1002
50
240
40*35 & 35*35
Group 8
6 inch Mono
6*20
1665*992 & 1684*1002
50 240
40*35
Group 11 6 inch Mono
6*24
1987*992 & 2000*992 & 2008*1002 50 240
40*35
Table 5 above: Mechanical dimensions when modules installed at short side with Clamp fitting method