background image

P/N 466-5224 

• REV C• 6NOV2015 

 

 

Concord 4 Touch Screen Installation Sheet 

Description 

The Concord 4 Touch Screen, model 60-924-3-C4TS, features 
a 3.5-inch color LCD screen with a graphical user interface 
designed to control basic functionality of the Concord 4, 
version 4.5 or later. 

Multiple touch screens can be added to each Concord 4 panel. 
An internal speaker provides system status beeps for trouble 
and alarm indications.

 

The touch screen provides a convenient option for the 
following system operations: 

• 

Easily obtain home/building status using At-A-Glance 
(AAG) sensor status. 

• 

Arm the system (doors, windows, motion sensors, and 
property). 

• 

Disarm the system. 

• 

Activate a panic alarm to call the central monitoring station 
in a non-medical emergency. 

Equipment

 

• 

Alphanumeric keypad (for panel and end user 
programming) 

• 

4-conductor, 22-gauge wire 

• 

#6 screws and anchors (included) 

• 

Super bus power supply (optional), PN 600-1019 

Tools 

• 

2.5mm flat-blade screwdriver 

• 

#2 Phillips screwdriver 

• 

Drill and drill bits for opening wallboard (1/8- and 1/2-inch 
bits) 

Safety information 

IMPORTANT SAFETY INFORMATION. READ ENCLOSED 

WARNINGS AND SAFETY INFORMATION. 

 WARNING: CHOKING HAZARD

.

 

The product accessory 

bag contains items that could be choking hazards. Please keep 
away from small children.  

 

ATTENTION: Le sachet d'accessoires produit contient des 
éléments qui pourraient être les dangers d'étouffement. 
Veuillez garder hors de la portée des jeunes enfants. 

 WARNING: 

Disconnect panel power before servicing.

 

Débrancher l'alimentation du panneau avant l'entretien.

 

 CAUTION: 

Use static electricity precautions when 

handling electronic components. Utiliser les précautions de 
l'électricite statique lors de la manipulation des composants 
électroniques. 

Installation 

Installation guidelines 

The touch screen is an auxiliary interface device and in its 
current version cannot be used to program the Concord 4. A 
full function alphanumeric keypad (such as Interlogix P/N 600-
1070 or 60-983) is required to be present. Consult the Concord 
4 Installation Guide for selection of a full function alphanumeric 
keypad. 

• 

The touch screen is not listed to UL Fire Standards and 
may not be programmed for use with a Fire System in 
California per CSFM Regulations. 

•   Mount the touch screen in an environmentally-controlled 

area (32°F to 120°F/0°C to 49°C). 

• 

Do not exceed the maximum available power given in the 
panel. Refer to the total system power and guideline 
section in Concord 4 installation instructions. See Table 1 
for touch screen power usage and Table 2 for maximum 
wire length between touch screen and panel. 

Table 1: Touch Screen Power Usage 

Current (mA) 

Conditions 

250 

Maximum alarm current with the buzzer sounding 
and the touch screen illuminated from a button 
press 

100 

Typical operation 

40 

Power saving mode (no panel AC power) 

 

Содержание 60-924-3-C4TS

Страница 1: ...oires produit contient des éléments qui pourraient être les dangers d étouffement Veuillez garder hors de la portée des jeunes enfants WARNING Disconnect panel power before servicing Débrancher l alimentation du panneau avant l entretien CAUTION Use static electricity precautions when handling electronic components Utiliser les précautions de l électricite statique lors de la manipulation des comp...

Страница 2: ...e by inserting a small screwdriver into the opening slot on the bottom of the touch screen Figure 1 Figure 1 Opening slot 2 Hold the base on the wall at the desired mounting location and mark the mounting holes and bus wire drop 3 At the mounting hole locations drill 1 8 inch holes into the wall for plastic anchors 4 At the bus wire drop opening drill a 1 2 inch hole into the wall 5 Push the two p...

Страница 3: ... and battery power from the panel 5 Replace the defective bus device with a new one 6 Apply AC and battery power to the panel Partition assignment With this menu assign bus devices to work in the desired partition To assign bus devices to partitions 1 With the display showing the desired bus device press 2 Press A or B until the display shows DEVICE PTN and then press The display shows PARTITION A...

Страница 4: ...ate the touch screen touch the icons in the corners of the screen using a soft fine point If unable to access calibration using the above procedure use the following steps 1 Press and hold the Reset button Figure 5 Figure 5 Touch screen reset button 2 Press and hold anywhere on the screen 3 While pressing the screen release the Reset button 4 Follow the calibration prompts Help Touch the Help butt...

Страница 5: ...ress volume levels in settings Check for correct wiring connections at touch screen and panel terminals Sensors named as door window motion are displaying under Property icon The name of the sensor is too long Place door window motion earlier in the name or shorten the name Touch screen has red icon offline This icon is displayed if a touch screen has incurred some form of communication and or har...

Страница 6: ...Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Warranty Information MANUFACTURER HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS WHETHER EXPRESS IMPLIED STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS CONCORD 4 ...

Отзывы: