background image

Concord 4 Touch Screen Installation Sheet  

Power up and bus communication 

Follow the steps below for powering up the panel and for 
verifying that the alphanumeric keypad, touch screen, and 
panel are properly communicating with each other.  

Note: 

An alphanumeric keypad is required for panel and end 

user programming. 

Note:

 On power up, the panel scans the bus for connected 

devices, assigns a unit number to each bus device, and 
automatically adds the device ID number of each bus device. 

1.  Verify that all wiring between the panel, touch screen, and 

alphanumeric keypad is correct. 

2.  Connect the panel battery and restore AC power.  

The alphanumeric keypad briefly shows

 SCANNING BUS 

DEVICES, 

then displays date and time. 

Note: 

Emergency button program changes can only be 

completed within two minutes of initial power up of touch 
screen.  

Verifying touch screen bus enrollment and panel 

programming touch screen options 

To enter programming with an alphanumeric touch pad, refer 
to the Concord 4 Installation Manual. 

1.  Go to the Bus Device Programming section in Concord 

(System Programming / Security / Accessory Modules / 
Bus Devices (shortcut 10,000 for unit ID 0). 

2.  The display shows the lowest device address and its ID.  

This example shows what a device address display may 
look like: 

UNIT - ID

 

02110185

*The 8-digit SuperBus ID number is also located on a label 
on the back of the alphanumeric keypad. 

3.  Cycle through all bus device addresses until the 

alphanumeric keypad appears. 

4.  To program the following touch screen options, choose the 

touch screen bus device address. 

Change ID 

With this menu, change the bus device ID number when 
replacing a defective bus device. 

To change a device ID: 

1.  With the display showing the desired bus device, press #, 

#.  

The display shows DEVICE ID (current ID). 

2.  Enter the ID of the new bus device.  

The display flashes the entered selection. Press #

 

and the 

display shows the new setting. 

3.  Exit programming mode. 

4.  Remove AC and battery power from the panel. 

5.  Replace the defective bus device with a new one. 

6.  Apply AC and battery power to the panel. 

Partition assignment 

With this menu, assign bus devices to work in the desired 
partition. 

To assign bus devices to partitions: 

1.  With the display showing the desired bus device, press #. 

2.  Press A

 

or B

 

until the display shows DEVICE PTN and 

then press #. The display shows PARTITION ASSIGN. 

3.  Press 1

 

to 6

 

to select the desired partition.  

The display flashes the entered selection.  

4.  Press #

 

and the display shows the new setting. 

Status beeps 

Option not used with touch screen. Touch screen status beeps 
can be changed in the touch screen settings menu. 

Key beeps  

Option not used with touch screen. Touch screen key beeps 
can be changed in the touch screen settings menu. 

Panel sensor text programming guidelines 

Programming for touch screen At-A-Glance (AAG) icons 

For best results, do not program sensor names that contain a 
combination of the words Door, Window, and/or Motion.  

The designator words Door, Window, or Motion should be 
programmed within the first three words of the sensor text 
sequence. If not, the wrong AAG association may occur. 

Door

 - Sensor names 

must contain “Door” (item number 50). 

When programming a name for a sensor, enter 50 and the 
word Door is added to the text. These sensors should be a 
sensor group that requires a restoral.  

Window 

- Sensor names 

must contain “Window” (item number 

183). When programming a name for a sensor, enter 183 and 
the word Window is added to the text. These sensors should 
be a sensor group that requires a restoral. 

Motion

 

-

 

Sensor names 

must contain “Motion” (item number 

119). When programming a name for a sensor, enter 119 and 
the word Motion is added to the text. These sensors should be 
a sensor group that does not require a restoral. 

Property 

- Any sensor that does not contain the words Door, 

Window, or Motion. They may be a restoral or non-restoral 
sensor. 

If a sensor contains the AAG keyword of Door, Window, or 
Motion, but the sensor appears in the Property AAG when 
tripped, the name of the sensor is too long. The AAG keyword 
needs to be moved closer to the start of the sensor name. 

Содержание 60-924-3-C4TS

Страница 1: ...oires produit contient des éléments qui pourraient être les dangers d étouffement Veuillez garder hors de la portée des jeunes enfants WARNING Disconnect panel power before servicing Débrancher l alimentation du panneau avant l entretien CAUTION Use static electricity precautions when handling electronic components Utiliser les précautions de l électricite statique lors de la manipulation des comp...

Страница 2: ...e by inserting a small screwdriver into the opening slot on the bottom of the touch screen Figure 1 Figure 1 Opening slot 2 Hold the base on the wall at the desired mounting location and mark the mounting holes and bus wire drop 3 At the mounting hole locations drill 1 8 inch holes into the wall for plastic anchors 4 At the bus wire drop opening drill a 1 2 inch hole into the wall 5 Push the two p...

Страница 3: ... and battery power from the panel 5 Replace the defective bus device with a new one 6 Apply AC and battery power to the panel Partition assignment With this menu assign bus devices to work in the desired partition To assign bus devices to partitions 1 With the display showing the desired bus device press 2 Press A or B until the display shows DEVICE PTN and then press The display shows PARTITION A...

Страница 4: ...ate the touch screen touch the icons in the corners of the screen using a soft fine point If unable to access calibration using the above procedure use the following steps 1 Press and hold the Reset button Figure 5 Figure 5 Touch screen reset button 2 Press and hold anywhere on the screen 3 While pressing the screen release the Reset button 4 Follow the calibration prompts Help Touch the Help butt...

Страница 5: ...ress volume levels in settings Check for correct wiring connections at touch screen and panel terminals Sensors named as door window motion are displaying under Property icon The name of the sensor is too long Place door window motion earlier in the name or shorten the name Touch screen has red icon offline This icon is displayed if a touch screen has incurred some form of communication and or har...

Страница 6: ...Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Warranty Information MANUFACTURER HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS WHETHER EXPRESS IMPLIED STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS CONCORD 4 ...

Отзывы: