manualshive.com logo in svg
background image

 

User’s Manual

 

 

iOne-MP17ix (MP176)

 

 

All-in-one Medical Panel PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright© ,2013. All rights reserved   

 

The information in this document is subject to change without notice.

 

Содержание iOne-MP17ix

Страница 1: ...1 User s Manual iOne MP17ix MP176 All in one Medical Panel PC Copyright 2013 All rights reserved The information in this document is subject to change without notice ...

Страница 2: ...ulatory Notice 3 11 A FCC Class B 3 3 B Electronic Magnetic Compatibility 4 8 C Safety 9 10 D Intended use 11 II Product Basic 12 18 A Specifications 12 14 B The Packing Outline I O Control Buttons 15 16 C Others 17 18 III BIOS 19 27 ...

Страница 3: ...ed to be causing harmful interference to radio or television reception this can be determined by turning the equipment on and off If interference is occurring the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to a power out...

Страница 4: ...e power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Recommended separation distances between portable and mobile RF communications equipment and the iOne MP176 The iOne MP176 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The user of th...

Страница 5: ...nity The iOne MP176 is intended for use in the electromagnetic environment specified below The user of the iOne MP176 should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floo...

Страница 6: ...P176 be powered from an uninterruptible power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE UT is the a c mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic imm...

Страница 7: ...watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequenc...

Страница 8: ...t due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the iOne MP176 used exceeds the applicable RF compliance level above the iOne MP176 should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the iOne MP176 b Over th...

Страница 9: ... display products please follow the guidance of your local authority or ask the shop where you purchased the product or if applicable follow any agreements made between yourself The mark on electrical and electronic products only applies to the current European Union Member States When networking with electrical devices the operator is responsible for ensuring that the resulting system meets the r...

Страница 10: ...equipment and IEC 60601 1 for medical equipment Furthermore all configurations shall comply with the system standard IEC 60601 1 1 Everybody who connects additional equipment to the signal input part or signal output part configures a medical system and is therefore responsible that the system complies with the requirements of the system standard IEC 60601 1 1 The unit is for exclusive interconnec...

Страница 11: ...ased solely on images displayed by this device Caution Use suitable mounting apparatus to avoid risk of injury The sound pressure level at the operator s position according to IEC 704 1 1982 is no more than 70dB A A Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade B Use a power cord that matches the voltag...

Страница 12: ...internal COM x 6 x 2 external x 4 internal Audio Realtek ALC262 audio codec 2 2 watts amplifier LAN Marvell 88E8071 Gigabit Ethernet x 2 BIOS AMI BIOS 4M EEPROM RTC wake up Wake on LAN Power on after power failure PnP ACPI Speaker 2 watts x 2 front bottom LCD Panel Size 17 5 4 Resolution 1280 x 1024 Brightness 380 nits Contrast 1000 1 Color numbers 16 7M 6 bit x 3 FRC Viewing angle 170 H 160 V Res...

Страница 13: ...ut medical grade Sinpro MPU101 105 Power consumption 75 watts typical without any add ons Internal battery optional Rechargeable Lithium Ion 2S2P 29 2Wh avg 27 74Wh min for 20 25 minutes operating approx Charge time 2 hours system off 3 5 hours system on Mechanical Environmental Housing Plastic front bezel rear cover and I O cover w antibacterial Coating White color IP rating IP65 front side Cooli...

Страница 14: ...0601 1 2006 ANSI AAMI ES60601 1 2005 CAN CSA C22 2 No 60601 1 08 Options Options WLAN mini PCIe module w internal antenna x 2 Bluetooth 2 1 USB Battery pack Power adaptor w 2 4m or 3 6m DC cable Desktop stand ...

Страница 15: ... The medical PC iOne MP17ix Power adaptor Sinpro MPU101 105 AC power cord Touch stylus pen DVD title with drivers user s manual User s manual Screws for rear cover VESA mounting Note The contents may vary due to different options or configuration Outline dimension ...

Страница 16: ...16 The I O interface basic configuration The control buttons From left to right Brightness Brightness Power on off Speaker volume Speaker volume ...

Страница 17: ...Touch panel 40 Sodium Hydroxid Damage Acetone OK Carbitol Acetate OK Cellosolve Acetate OK Ethanol Alcohol OK Methylene Chloride OK Hydrochloric Acid 6 OK Hexane OK Isopropanol Isopropyl Alcohol Propanol OK Methyl Ethyl Ketone OK Heptane OK Toluene Damage Turpentine OK Vm P Naptha OK Bleach Sodium Hypochlorite NaOCI Damage Benzyl alcohol OK Hydrogen peroxide Damage Chemical Plastic housing 40 Sodi...

Страница 18: ...um Ion rechargeable battery cell 2000mAh cell Configuration 2S2P Typical capacity 4000mAh for two cells Minimum capacity 3800mAh for two cells Nominal voltage 7 3 V average Energy 29 2 Wh typical 27 74 Wh minimum Charge voltage 8 4 V typical Charge time System on 1A 200 minutes System off 2A 120 minutes Battery life Discharge 10 minutes for 300 times 70 capacity left During the transportation we s...

Страница 19: ...iately after powering on the system during the POST Power On Self Test stage press the Del key to enter the BIOS setup utility program Follow the menu the keys instruction to modify the BIOS configuration settings Main ...

Страница 20: ...he system will enter when the SUSPEND button is pressed Lock Legacy Resources Enables or Disables Lock of Legacy Resources S3 Video Repost Enables or Disables S3 Video Repost S5 RTC Wake Settings Wake System with Fixed Time Enables or disables system wake on alarm event When enabled the system will wake on the time specified Wake system with Dynamic Time Enables or disables system wake on alarm ev...

Страница 21: ... Bit XD can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 RedHat Enterprise 3 Update 3 Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Hardware Prefetcher To turn on off the Mid Level Cache L2 streamer prefetch...

Страница 22: ... for 0Ses without EHCI hand off support The EHCI ownership change should be claimed by EHCI driver USB Mass Storage Driver Support Enable Disable USB Mass Storage Driver Support USB transfer time out The time out value for Control Bulk and Interrupt transfers Device reset time out USB mass storage device Start Unit command time out Device power up delay Maximum time the device will take before it ...

Страница 23: ...23 Set Parameters of Serial Port 4 Serial Port 5 6 Configuration Optional Serial Port 5 Configuration Set Parameters of Serial Port 5 Serial Port 6 Configuration Set Parameters of Serial Port 6 ...

Страница 24: ...24 Chipset System Agent SA PCH IO Configuration This screen provides information on System Agent and PCH parameters ...

Страница 25: ...llows you to determine whether to display the Logo at system startup Disabled displays normal POST message Fast Boot Enables or disables the quick boot function to speed up the system boot up process to shorten the waiting time for entering the operating system and to deliver greater efficiency for daily use CSM16 Parameters Enable Disable option ROM execution settings etc CSM parameters Option RO...

Страница 26: ...26 Security Enables or disables the security chip It is recommended that you use this function with the Administrator User password ...

Страница 27: ...ave Changes Save the changes done so far to any of setup options Discard Changes Discard the changes done so far to any of setup options Restore Defaults Restore load default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Launch EFI Shell From filesystem device Attempts to...

Отзывы: