After entering the main menu interface select “Actuator”
,
then enter the
sub-menu press the up and down keys to select " Gasoline nozzle (Current) "
,
press “OK” button, after confirmation, before entering oscilloscope operation
interface, it will prompt "must comply with the current clamp using " Wait a few
seconds to enter the oscilloscope interface
③
Connect current clamp to CH1,since the “Gasoline nozzle (Current)” Function of
oscilloscope has default settings
(
Probe 1X
,
time base 1ms
)
,simply connect the
probe to the corresponding signal can display waveform.
④
Press“CH1”
,
can view the values and configuration
(
configuration has default
)
⑤
Waveform display can be adjusted based on their own through the vertical volts /
division and trigger ways to meet your needs
(
Time base, vertical volts / division
and other specific operations, please refer to the operation of general oscilloscope
)
4
)
Gasoline nozzle (Voltage and Current)
①
Same as Electromagnetic valve step 1
②
After entering the main menu interface select “Actuator”
,
then enter the
sub-menu press the up and down keys to select " Gasoline nozzle (Voltage and
Current) "
,
press “OK” button, after confirmation, before entering oscilloscope
operation interface, it will prompt " CH1:using probe
,
CH2:using current clamp"
Wait a few seconds to enter the oscilloscope interface
③
Connect the probe to CH1 and probe set to 10X
,
then connect grounding clip to
the signal ground or grounding. Connect the current clamp to CH2
④
Since the “Gasoline nozzle (Voltage and Current)” of oscilloscope has default
settings
(
CH1:Probe 10X
,
time base 1ms; CH2: Probe 1X
,
time base
1ms
)
,simply connect the probe to the corresponding signal can display waveform,
as picture 13
⑤
Press“CH1” and “CH2”
,
can view the values and configuration
(
configuration has
default
)
⑥
Waveform display can be adjusted based on their own through the vertical volts
/ division and trigger ways to meet your needs
(
Time base, vertical volts / division
and other specific operations, please refer to the operation of general
oscilloscope
)
Pic-13 Gasoline
nozzle (Voltage and Current)
Voltage
Current