20
⑤
Pres
s“CH1”
,
can view the values and configuration
(
configuration has default
)
⑥
Waveform display can be adjusted based on their own through the vertical volts /
division and trigger ways to meet your needs
(
Time base, vertical volts / division and
other specific operations, please refer to the operation of general oscilloscope
)
2
)
Gasoline and diesel fuel nozzle
①
Same as Electromagnetic valve step 1
②
After entering the main menu interface select “Actuator”
,
then enter the
sub-menu press the up and down keys to select " Gasoline and diesel fuel nozzle "
,
press “OK” button, after confirmation, entering oscilloscope operation interface
③
Connect the probe to CH1 and probe set to 10X
,
then connect grounding clip to
the signal ground or grounding.
④
Since the “Gasoline and diesel fuel nozzle” Function of oscilloscope has default
settings
(
Probe 10X
,
time base 1ms
)
,simply connect the probe to the
corresponding signal can display waveform.
⑤
Press“CH1”
,
can view the values and configuration
(
configuration has default
)
⑥
Waveform display can be adjusted based on their own through the vertical volts /
division and trigger ways to meet your needs
(
Time base, vertical volts / division
and other specific operations, please refer to the operation of general oscilloscope
)
Note:
there is a rectangular concave on waveform, the width of the rectangle is the
actual fuel injection pulse width, after the engine entering the closed-loop control,
fuel injection pulse width is generally 1.5ms-2.9ms. If bigger than this value, there
are clogging or excessive intake and other issues of nozzle.
3
)
Gasoline nozzle (Current)
①
Same as Electromagnetic valve step 1
Pic-12 Electromagnetic valve