ADO102 \ ADO104 automotive oscilloscope manual 

 

   

ADO102  \  ADO104  automotive  oscilloscope  is  a  portable  device  developed  and 

produced  by  JH  Company.  This  product  is  compact,  portable,  and  flexible  operation; 

Using  color  TFTLCD  and  pop-up  menus  to  display;  to  achieve  its  ease  of  use,  greatly 

improving the user productivity. 

    In  addition,  this  product  has  superior  performance  and  it  is  powerful,  affordable,  high 

cost.  The  real-time  sampling  rate  can  be  as  high  as  100MSa/S,can  meet  the  capture 

speed,  market  demand  for  complex  signals  and  auto  repair  market;  Support  for  USB 

storage  devices,  users  can  upgrade  via  USB,  Special  test  project  and  Universal 

oscilloscope to meet different levels of customer needs. 

 

Characteristic: 

Model 

Bandwidth 

ADO 102 

Dual channel 

ADO 104 

Four channel 

 

—New ultra-thin design, small volume, light weight, convenient carrying 
—Color TFTLCD display, 320*240 resolution, waveform display more clearly, stability 
—Four analog channel (ADO102 for Dual channel) 
—Can  be  convenient  to  realize  the  car  corresponding  module  features  one-button 
operation 
—Any interface screenshot (press F2 screenshot) 
—Screenshot can preview 
—Support for USB storage device 
—Have  the  edge  trigger  function,  under  universal oscilloscope mode  can  automatically 
detect the support (20Hz - 10MHz) 
—Support time and voltage cursors 
—Support A variety of waveforms mathematical sum 
—Adding a variety of waveform math functions   
—Support Chinese and English menu display 
—A variety of display styles 
—Backlight brightness can be adjusted 
—Long standby: single cell battery can work continuously for 5 hours 
—With a digital multimeter functions   

 
 

 
General safety requirements: 

The following safety precautions to avoid injury; And to prevent the product or any other 

products  connected  from  the  damage.  To  avoid  possible  danger,  be  sure  to  use  the 

Содержание ADO102

Страница 1: ...olume light weight convenient carrying Color TFTLCD display 320 240 resolution waveform display more clearly stability Four analog channel ADO102 for Dual channel Can be convenient to realize the car corresponding module features one button operation Any interface screenshot press F2 screenshot Screenshot can preview Support for USB storage device Have the edge trigger function under universal osc...

Страница 2: ...uit exposed After the boot Do not touch exposed connections and components Suspected product failure do not operate If you suspect that the product has failed you can ask a qualified service personnel To maintain adequate ventilation Do not operate in wet conditions Do not operate in the flammable explosive environment Please keep the product surface is clean and dry 2 Security terminology and lab...

Страница 3: ... handheld oscilloscope s front panel user interface functional check and probe compensation Features and Operation a detailed presentation for functions and operations of universal oscilloscope and automotive oscilloscope and multimeter The application example provide some measurement example for reader reference System Tips and Troubleshooting Service and Support Appendix ...

Страница 4: ...set 25 4 Default settings 26 5 Vertical Systems 26 6 Horizontal Systems 27 7 Trigger system 28 8 Math System 29 9 System Setup 30 10 The storage system 31 2 3 Multimeter function and operation 32 Chapter3 Application Examples 34 3 1 Singal measure 34 3 2 Cursor measure 34 3 3 Capture the Single Signal 35 3 4 Use Multimeter to Measure DC Voltage 36 Chapter 4 System Tips and Troubleshooting 36 4 1 P...

Страница 5: ...O series front panel operation and function To make use of you in the shortest possible time familiar with the oscilloscope ADO provide users with a clear and simple front panel To facilitate the user to perform basic operations On the left and right side of the display panel is marked with various function keys Key to set the different options up and down through the menu The red substrate power ...

Страница 6: ... compensation as follows 1 Set the Probe option attenuation to 10X in the channel menu The switch on the probe is also set to 10X And oscilloscope probe connected to channel 1 If using the probe hook tip ensure reliable contact with the probe 2 Connect the probe tip and the signal generator output connector Grounding clip and signal generator is connected to the ground connector Display Channel Th...

Страница 7: ...sary Chapter 2 Describes of the function and operation In order to use ADO Series oscilloscope effectively you need to understand the main functional framework of the oscilloscope This chapter is divided into three modules to introduce oscilloscope according to the functional framework automotive oscilloscope general oscilloscope multimeter ...

Страница 8: ...eform pictures of each functional test in text are from Dodge Journey 2 4 L model cars different models measured different waveforms so there will be differences 1 Quick Operation Guide Setting essentials 1 Wave height adjustment amplitude Press the corresponding channel and adjust through the up and down keys 2 Waveform overall move Press the corresponding channel and then adjust through the left...

Страница 9: ...ding to working order of engine Spark plugs lead ignition high voltage to cylinder combustion chamber and produce spark between the electrodes Igniting the combustible mixture The advantage of this ignition system is relatively easy for detection service one of the disadvantage is mechanical parts and electrical contacts easy to wear short life And the high voltage connector portion also easily da...

Страница 10: ...el sensors or camshaft sensor Ignition control module calculates ignition time and charging time based on the collected information If a sensor is not working properly it will cause the output signal is incorrect so modern control module have to check whether the signal sent by the sensor is authentic when there are untrusted signal it may not output any signal Ignition control module output signa...

Страница 11: ...12 V square wave 7 Secondary ignition When ignition coil secondary generates a high voltage when the voltage is gradually increased to a certain value the spark plug produce sparks this voltage is the ignition voltage The voltage then drops rapidly to another voltage value and maintained for some time this voltage is the combustion voltage combustion time is the time of voltage maintained at a com...

Страница 12: ...ge or spark plug gap is too large may have resulted in the phenomenon of high breakdown voltage Conversely if the breakdown voltage is too low It indicates that the resistance value in ignition secondary circuit is lower than normal spark plugs may be dirty or rupture high voltage leakage and other reasons caused Combustion line and combustion time if combustion line has too much clutter It repres...

Страница 13: ...ignition into the ignition function selection interface then you can enter the user interface through up and down keys to select the primary ignition as picture 2 Connect the probe to CH1 and probe set to 10X then connect grounding clip to the signal ground or grounding Since the primary ignition of oscilloscope has default settings Probe 10X time base 1ms Simply connect the ignition coil to the p...

Страница 14: ... default settings Probe 10X time base 1ms ignition system with sub cylinder line probe with capacitor small black squares side is sandwiched with sub cylinder line the other side connected to the ground or battery negative If the car is an independent ignition system you need to buy independent ignition extension cord one side connect to ignition coil one side connect to spark plug the role is to ...

Страница 15: ...e interface Connect current clamp to the oscilloscope CH1 since the primary ignition oscilloscope is default setting probe 1X time base 1ms simply connect the current clamp to ignition coil then waveform can be visually displayed As pic 2 Press CH1 you can view the value and configuration configuration has default Displayed waveform can be realized through the self regulating group vertical volts ...

Страница 16: ...nd CH2 separately and set probe to 1X then connect grounding clip to signal ground or grounding Since the magnetic electric and Hall function of oscilloscope has default settings probe 1X time base 10ms just need to connect two probes to corresponding signals then the waveforms can be displayed as pic 4 measured waveform is under 800 rpm Press CH1 or CH2 can view the values and configuration confi...

Страница 17: ...nding signal To intuitive display waveforms as shown in Figure 5 Press CH1 you can view the value and configuration by default waveform can be self fulfilling their needs by adjusting the time base vertical volts division and trigger mode time base vertical volts division and other specific operations please refer to the Universal oscilloscope operation 3 The oxygen sensor zirconium type titanium ...

Страница 18: ...kly brought under control Four wire a signal line and a signal ground Two other heating device lines Zirconium oxygen sensor needs to reach more than 300 degrees Celsius temperature in order to work properly this kind of oxygen sensor normal output feedback voltage change between 0 1V 0 5V above the output indicates that the mixture is too thick 0 5V output indicates that the appropriate balance b...

Страница 19: ...sion and trigger mode time base vertical volts division and other specific operations please refer to the Universal oscilloscope operation Note Open the ignition switch do not start the engine to detect the throttle position sensor signal slowly open to close the throttle observe the waveform has no sudden or irregular changes in the situation When the throttle position sensor is analyzed it is po...

Страница 20: ... change of 0 5V between the voltage signal transmitted to the oscilloscope Start the engine step on the accelerator pedal then the air flow signal should be with the throttle valve opening bigger and the higher the value In the idle speed should be kept stable when the throttle valve is fully open the signal will be increased to the maximum value Watch the waveform signal in the abnormal phenomeno...

Страница 21: ...user interface Connect the CH1 probe to the oscilloscope and set probe to 1X file transfer then connect the grounding clip to the signal ground or grounding Since the oscilloscope intake manifold absolute pressure sensor function has already default settings profiles probe 1X time base range 500ms just probe to the corresponding signal to intuitive display waveforms as shown in Figure 9 Note As in...

Страница 22: ...1X time base range 250ms just probe to the corresponding signal to intuitive display waveforms as shown in Figure 11 Note As in the SCAN scan mode requires patience waveform scanned Press CH1 you can view the value and configuration by default waveform can be self fulfilling their needs by adjusting the time base vertical volts division and trigger mode time base vertical volts division and other ...

Страница 23: ... grounding Since the Gasoline and diesel fuel nozzle Function of oscilloscope has default settings Probe 10X time base 1ms simply connect the probe to the corresponding signal can display waveform Press CH1 can view the values and configuration configuration has default Waveform display can be adjusted based on their own through the vertical volts division and trigger ways to meet your needs Time ...

Страница 24: ...agnetic valve step 1 After entering the main menu interface select Actuator then enter the sub menu press the up and down keys to select Gasoline nozzle Voltage and Current press OK button after confirmation before entering oscilloscope operation interface it will prompt CH1 using probe CH2 using current clamp Wait a few seconds to enter the oscilloscope interface Connect the probe to CH1 and prob...

Страница 25: ... CH2 probe set to 1X then connect grounding chipotle signal ground or grounding Since the CAN high CAN low function of oscilloscope has default settings CH1 CH2 Probe 1X time base 25us simply connect the probe to the corresponding signal can display waveform as picture 14 Press CH1 and CH2 can view the values and configuration configuration has default Waveform display can be adjusted based on the...

Страница 26: ... high CAN low step 1 After entering the main menu interface select Bus then enter the sub menu press the up and down keys to select FlexRay press OK button after confirmation entering oscilloscope operation interface Connect the two probes to CH1 and CH2 probe set to 1X then connect grounding clip to the signal ground or grounding Since the FlexRay Function of oscilloscope has default settings CH1...

Страница 27: ...orizontal control menu Continuously acquires waveforms or stops the acquisition Note In the stop mode the waveform vertical scale and horizontal base can be adjusted within a certain range equivalent to extend the signal on the horizontal or vertical direction MENU Function menu interface the first press of waveform storage interface the second press to display settings interface press three times...

Страница 28: ...t waveform connection COM and VΩ is used to connect the black and red pen 3 Automatically set ADO has an automatic setting function According to the input signal automatically adjusting the voltage stall time base and triggering the best way to form display AUTO for automatically setting If there is more than one channel signal the channel with the lowest frequency signal as the trigger source Fou...

Страница 29: ...splay Open Close Open display waveforms Close display waveforms Frequenc y Automatically displays the current input signal frequency peak to peak value Automatically displays the current waveform peak to peak value Duty Cycle automatically displays the current input signal duty Cycle automatically displays the current input signal cycle 1 Set the channel coupling To signal applied to the oscillosc...

Страница 30: ...ision press or to move up and down the entire waveform As Figure 2 7 If you set the vertical direction 1 00V div the steps in the above example As Figure 2 8 Figure 2 7 Figure 2 8 6 Horizontal Systems Use the control buttons to change the level of the horizontal scale time base trigger horizontal position trigger position in memory Changing the horizontal scale causes the waveform relative to the ...

Страница 31: ... press the time base on the cursor key to enter the display interface and then or key to adjust the cursor position 7 Trigger system The trigger determines when the oscilloscope starts to acquire data and display waveforms Once the trigger is set up correctly it can convert the unstable display into meaningful waveforms Trigger Control menu button TRIG Trigger Control Trigger The oscilloscope trig...

Страница 32: ...ing trigger flag each cell voltage value represents the relative position and the current channel a flag vertically to set the trigger level size Set slope 3 Press the F2 key to select slope up or down Set trigger mode 4 Press the F4 key to select Auto normal or single Auto Set in the absence of detectable also can collect waveform trigger conditions Normal Set only a triggering condition is satis...

Страница 33: ...OK button to enter the settings interface via the arrow keys to select Sound press OK button enter the change left and right keys to select On or Off and then press OK button to confirm 2 brightness setting the main menu select System Settings button press the OK button to enter the settings interface via the arrow keys to select Brightness press OK button to enter modify add brightness left minus...

Страница 34: ...ssing the F2 button selected as the reference NULL to close the reference waveform Store pictures steps Any Screenshots 1 Oscilloscope and automotive modules interface long press F2 operating status battery indicator on the left side will be blinking green to being shot wait a few seconds the name of the successful bomb box prompts screenshots and screenshots will appear 2 Multimeter screenshot wi...

Страница 35: ...uzzer off This device uses TFT full color display and has a range display polarity display overload display battery power display Meas ure Type Range DC Voltag e 400 0m V 4 000V 40 00V 400 0V 1000 V AC Voltag e 400 0m V 4 000V 40 00V 400 0V 750V Resist ance 400 0 Ω 4 000 KΩ 40 00 KΩ 400 0 KΩ 4 000 MΩ 40 00 MΩ Capa citanc e 51 2nF 512 0nF 5 120uF 51 20uF 100u F Diode 0V 1 5V Buzze r off Below 60Ω b...

Страница 36: ...to the measured voltage the device will read the value and show on the screen it can also read negative value AC Voltage has no polarity This device s default Range is Auto you can press or to change the Range Resistance measuring Press or to select Resistance mesuare it has a shortcut F2 Put the pen on the two side of the resistor device can read it s value Maybe you should set the Range manually...

Страница 37: ... the value immediately please do as fllows Enter the Universal oscilloscope Set the probe menu attenuation coefficient as 10X and switch the probe to 10X Connect the CH1 probe to the test point Press AUTO key The OSC will automatically set the optimum waveform display Then you can adjust the Vertical or Horizontal scale until the waveform meets your requirements Automatic measure signal s voltage ...

Страница 38: ...d easily capture the periodic signal pulses glitches etc To capture a single signal this signal first needs to have some prior knowledge in order to set the trigger level along If the case of a signal of uncertainty you can automatically trigger mode or normal first observation to determine the trigger level along Steps are as follows 1 As aforementioned set the attenuation coefficient of probe an...

Страница 39: ...e pen on the test point and it will read The value See Figure 3 5 Set the Voltage Range manually Press or to select DC Press or to adjust the range See figure 3 6 Chapter 4 System Tips and Troubleshooting 4 1 Prompting Message Trigger level limit Horizontal position limit Voltage range limit USB storage device is connected successfully 4 2 Troubleshooting 1 If you press the button oscilloscope scr...

Страница 40: ...epped waveform display This phenomenon is normal When the base level is too low may stall increasing the level of the base when the horizontal resolution can be increased to improve the display Chapter 5 service and support 5 1 Warranty Description We guarantee the production and sale of its products the date of shipment from authorized dealers within a year does not appear in material and workman...

Страница 41: ...e probe X100 2000V voltage can be measured Probe attenuation 1X 10X Set the probe attenuation factor 1X 10X 100X Signal acquisition system Sampling Method Real time sampling random sampling Memory depth 4K Acquisition Mode Sample Peak Detect Vertical System Vertical Sensitivity 10mV 5V Probe 1X 100mV 50V probe 10X 1 2 5 5 step Vertical accuracy 3 Vertical resolution 8bit Bandwidth 10MHz Horizontal...

Страница 42: ...e Six broken wire needle Lithium battery 2 lithium batteries 2 Battery Charger Battery Charger Portable Kit Portable Kit USB cable one USB cable one Appendix C routine maintenance and cleaning Routine maintenance Do not store or leave the instrument in where the LCD display will be exposed to direct sunlight for a long time Do not allow sprays liquids and solvents touches on the instrument or prob...

Страница 43: ...tery before wiping Use a mild detergent and water to scrub Do not use any corrosive chemicals to avoid damage to the instrument and probe WARNING Before reinstalling the battery make sure the instrument is completely dry to avoid water damage to equipment caused by electrical short circuit ...