JetMove 208-480
12 Ethernet Interface (Option)
Jetter AG
93
Configuration File
In order to gain access to the configuration file "System/cfgvar.ini" via FTP, the user
having got the administrator rights has to be logged in.
This file has the same structure as a Windows *.INI file:
[CFGVAR]
Version = 4
IP_Address = 192.128. 10. 97
IP_SubNetMask = 255.255.255. 0
IP_DefGateway = 192.128. 10. 1
BasePort = 50000
IP_DNS = 192.118.210.209
Registers
Alternative access to the configuration memory is possible via registers 10131
through 10145.
In order to make a change via registers, first password register with password value
2002149714 (0x77566152) must be loaded. Then, registers 10132 through 10145
are modified. Finally, the changes to the configuration memory have to be saved by
entering an arbitrary value into register 10100.
Important!
Never change the version number!
Register
Meaning
Value Used in
the Example
10100
Saving the configuration values
10131
Version number
4
10132
IP address MSB
192
10133
IP address 3SB
128
10134
IP address 2SB
10
10135
IP address LSB
97
10136
Subnet mask MSB
255
10137
Subnet mask 3SB
255
10138
Subnet mask 2SB
255
Содержание JM-208-480-OEM
Страница 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Страница 22: ...1 Safety Instructions 22 Jetter AG...
Страница 34: ...4 Physical Dimensions 34 Jetter AG...
Страница 42: ...5 Technical Data 42 Jetter AG...
Страница 82: ...9 Diagnostics 82 Jetter AG...
Страница 86: ...10 Connection Diagrams 86 Jetter AG...
Страница 106: ...13 Safe Standstill Option 106 Jetter AG...
Страница 116: ...15 Ordering Information 116 Jetter AG...
Страница 117: ...JetMove 208 480 Appendices Jetter AG 117 Appendices...
Страница 118: ...Appendices 118 Jetter AG...
Страница 127: ...JetMove 208 480 Appendices Jetter AG 127...