JetMove 208-480
7.1 Connection of the Power Supply
Jetter AG
45
7
Description of Connections
7.1
Connection of the Power Supply
Specification of Terminal X1
• 4-pin plug; screw connection (Type: Phoenix PC 6/4-ST-10.16)
• Allowed conductor size: max. 0.5 ... 6 mm
2
(AWG 20 ... 7)
• Torque: 1.2 ... 1.5 Nm (10.6 ... 13.3 lbf-inch)
• Ambient temperature: 45 °C max.
• Field wiring
Connecting Cable Specifications
• Cable size: min. 4 * 1.5 mm² (AWG 16)
• Material: Copper
• Temperature class: 60 °C
Shielding
• Not required.
Fig.: 8: Connection of the power supply
Power Supply
Amplifier Terminals X1
Power Lines
Specifications
U1
L1
• AC 400 ... 480 V
between the power lines
V1
L2
W1
L3
PE (GND)
PE / GND conductor
U1
V1
W
1
PE
yellow / green
PE
Core 3
Line voltage 3
Core 2
Line voltage 2
Core 1
Line voltage 3