Mounting the nozzle assebly (picture number 7a ABS version)

Guide the air nozzle (1) into the wall fitting (2) and secure with countersunk screws (M 5 x 20) (3). Fit the O-ring (4) in the groove
(5) of the wall fitting (2).

Pools with plastic liner or prefabricated pools (picture number 7a ABS version)

In the case of liner pools or pre-fabricated pools, i.e. pools requiring a clamping ring (6), the distance ring (7) should be placed
centrally over the clamping ring (6) in such a way that the recessed section (8) is topmost.

Insert the nozzle housing (9) into the wall fitting ensuring that the coutersunk holes (11) on the nozzle housing line up with the
threaded holes in the wall fitting (10). Now push the nozzle housing into the wall fitting so that the stainless steel front plate (12) of
the nozzle housing rests against the tiles in the case of tiled/mosaic pools, or fits into the recess (8) if the distance ring is used.
Insert the countersunk screws (13) and screw in without over tightening.

Mounting the intake screen and pump with suction hose (picture number 7a ABS version)

Centre the intake screen (14) on the wall fitting (15) in such a way that the threaded holes in the wall fitting are in line with the
countersunk holes of the intake screen. Insert countersunk screws (16) without over tightening.

Installing the air inlet fittings (picture number 7a red bronze version and ABS version)

It is advisable to make provision for protecting the pneumatic tube (PVC 2/4 Dia.) and air inlet tube(s) (PVC 12/21 Dia.) by placing
in protective conduit or through adjacent cable/ ventilation ducts.

Note:
The air inlet fittings (33) consist of a ball type non return valve with a straight connector (32), pipe clip (34)
and fixing clip (35). The air inlet fittings (33) should be located behind the pool wall with their openings at
least 5 cm above the maximum water level of the pool, away from the pump chamber to avoid any possibility
of flooding.

The 4 m length of air inlet tube  may be shortened if necessary.  The shorter the tube, the lesser the resistance, and the higher the
volume of air flow.
Steps should be taken to ensure that builders debris does not enter the tube or valve during the course of construction. The
purpose of the non return valve is to prevent water spraying out of the air inlet fitting. The valve will only function properly as long
as no hair/debris or lime deposit accumulates within it.
Fit the supplied air inlet valves to the end of the air suction hoses. Push the hose nipple (32) of the valve (33) into the hose and
secure by means of the hose clips (34). Fasten the pipe clip (35) with screw supplied to an adjacent wall.

Pneumatic switch operable from pool  (Accessory picture number 7a red bronze version and ABS version)

Turn gland nut (40) anto-clockwise in order to remove it together with blank sealing disc from wall fitting whilst ensuring that the
rubber sealing washer (42) remains inside the gland aperture in wall fitting (41).
Thread free end of the 10 m length of pneumatic tube (47) through the gland aperture from within the pool.
On the pneumatic switch is a short length of pneumatic tube (44). Thread this through the gland nut (40), soften end of tube and fix
to the free end of tube connector (42). Replace and tighten the gland nut (40), having ensured that tube connector (45) is flush
against the rubber sealing washer in the housing (41). Coil surplus pneumatic tube (44) around rear end of switch assembly (43).
Push the switch assembly (43) into the wall fitting so that the outer flange (50) is in contact with the pool wall ensuring that the
pneumatic tube does not get crushed. Line up the countersunk holes in the switch assembly (50) with the threaded holes in the
wall fitting (41) and screw in the countersunk screws (47) without over-tightening.

Assembly of pump, suction tube and pressure tube (picture 7a ABS version)

The pump should be assembled beneath the water level.If the pump is to be installed on a console/mounting bracket, supplied as
an optional extra, it should be fitted to the pool wall beforehand with concrete wall fixings. The pump should be secured with anti-
vibration mountings. Alternatively, the pump should be secured with appropriate fixings on a concrete plinth. Glue the suction tube
and the pressure tube by means of an appropriate bonding agent.

Do not forget to insert the gasket (26) between hose nipple and pump nipple.

Tighten the pump base with fixing bolts or anti-vibration mountings.

Important note:
The pump is normally installed in the walkway behind the pool wall. The installation environment must be dry
and must be protected by a suitably sized floor drain to prevent flooding.

Mounting the intake screen and pump with suction hose (picture number 7a red bronze version and ABS version)

Centre the intake screen (14) on the wall fitting (15) in such a way that the threaded holes in the wall fitting are in line with the
countersunk holes of the intake screen. Insert countersunk screws (16) without over tightening.

Mounting the control panel (picture number 7a red bronze version and ABS version)

The control panel must not be installed in a chamber. It should be accommodated either in a dry walkway behind the pool wall or
in an adjacent room. The connection must be effected carefully in accordance with EN 60335-2-41. Connection to the power
supply is effected by means of a 5 x 2,5 mm² (3N  PE 400V) cable or a 4 x 2,5 mm² (3  PE 230 V) cable. Both a power switch, with
which the unit can be isolated from the power supply on all poles, and an earth leakage circuit breaker (R.C.C.B.) should be
provided in this cable (see: “Information for the Electrician”).

Warning

Warning

Warning

Содержание VIVA

Страница 1: ...1 MONTAGE UND BEDIENUNGSANLEITUNG INSTALLATION AND OPERATING INSTRUCTIONS INSTRUCTIONS DE MONTAGE ET MODE D EMPLOI VIVA...

Страница 2: ...2 D Inhaltsverzeichnis MONTAGE UND BEDIENUNGSANLEITUNG Seite 3 11 GB Table of Contents INSTALLATION AND OPERATING INSTRUCTIONS page 12 19 F Contenu INSTRUCTIONS DE MONTAGE ET MODE D EMPLOI page 20 27...

Страница 3: ...Schwimmb dern im Freien bei einer Wassertemperatur bis zu 35 C Die Ger te sind zur Aufstellung und Betrieb in Anlagen und R umen in den Bereichen 1 und 2 nach DIN VDE 0100 T 702 geeignet Die Pumpe wir...

Страница 4: ...e einzuhalten Ist das Ger t komplett montiert und elektrisch angeschlossen kann das Ger t in Betrieb genommen werden Bevor Sie die uwe JETSTREAM Anlage in Betrieb nehmen drehen Sie den Motor am L fter...

Страница 5: ...telgeh use D se Verrohrung bauseits PVC Rohr NW 50 ND 6 Klemmrahmen Dichtung Senkschraube M 6x30 mind 150 von jeder Wand min 40 Becken boden Senkschraube M 6x30 Ma e in cm Ausschnitt und Bohrungen in...

Страница 6: ...ausgleich bis 6 cm Einsetzen der Rohbauteile in die Schalung Montage Bild 1a Ausf hrung ABS Setzen Sie die Rohbauteile b ndig mit der Beckenwand ein Beton Erh lt das Becken f r eine Folienauskleidung...

Страница 7: ...g bauseits PVC Rohr NW 54 D 63 Ausschnitt und Bohrungen in der Beckenwand am besten mit Hilfe des Klemmrahmens anreissen bzw abbohren Senkschraube M 6x30 Flachkopfschraube M5 Ma e in cm Ma e in cm Was...

Страница 8: ...htung 18 nicht vergessen Hanfen Sie den Doppelnippel 20 den Schieber 21 den Spezialbogen von 90 Grad und den Saugschlauch 23 ein Schrauben Sie entweder die Pumpe 24 mit den mitgelieferten Ankerschraub...

Страница 9: ...9 7...

Страница 10: ...in der Beckenwand Sonderzubeh r Bild 7a Ausf hrung Rotguss und Ausf hrung ABS Drehen Sie die Druckschraube 40 aus dem Rohbauteil 41 heraus Entfernen Sie die Dichtscheibe Belassen Sie aber unbedingt di...

Страница 11: ...Ausf hrung ABS Der Steuerkasten sollte entweder in einem trockenen Umgang oder in einem angrenzenden Raum untergebracht werden Der Anschluss ist nach DIN VDE 0100 Teil 702 auszuf hren In die Netzzulei...

Страница 12: ...annot fall into the water Units of enclosure class I must be permanently connected to permanently laid cables 1 4 Proper Operation All units are intended soleley for operation in covered swimming pool...

Страница 13: ...mosaics In the case of a concrete liner pool first stage components may project in order to compensate for cement render or liner insulation thickness Locate the pneumatic switch housing in a conveni...

Страница 14: ...ntilation ducts Tile plan picture number 2a and 3a ABS version Render and tile to inner edge Render tile 6 cm max Pools with plastic liner picture number 5 red bronze version picture number 5a ABS ver...

Страница 15: ...VC tube NW 54 D 63 nozzle housing dimensions in cm dimensions in cm 24 24 45 22 5 15 1 7 8 x 4 5 3 6 0 2 2 5 2 2 5 26 M 6 M 5 5a min 40 air inlet tube for air suction end part to be installed 5 10 cm...

Страница 16: ...PTFE tape or similar sealing material The plastic suction and pressure hose connectors should be connected to the plastic pump casing 28 34 first ensuring that the fibre washers 26 are in place The pl...

Страница 17: ...17 7...

Страница 18: ...nd ABS version Turn gland nut 40 anto clockwise in order to remove it together with blank sealing disc from wall fitting whilst ensuring that the rubber sealing washer 42 remains inside the gland aper...

Страница 19: ...19 7a 49 48 44 26 33 35 47 50 43 40 42 46 41 45 25 24 16 13 12 8 7 32 34 15 14 4 3 1 10 5 2 9 6...

Страница 20: ...onsabilit pour tout dommage r sultant d utilisation incorrecte ou non conforme Seul l utilisateur en est tenu responsable La conformit d utilisation de l appareil comporte gale ment le respect des con...

Страница 21: ...vec la paroi de b ton Retirer la protection seulement avant la pose des carrelages Si le bassin re oit pour un rev tement liner des plaques d enduit et d isolation il faut avancer le bo tier de la pi...

Страница 22: ...1a 2a mesure en cm 3a 6 cm 24 10 35 24 10 2 40 40 24 17 tuyau en PVC MW 50 DIN 6 vous incombant planche de coffrage monter la pi ce surface plane avec la paroi de b ton vis t te cylindrique M 6x35 pie...

Страница 23: ...er anneau de serrage liner mesure en cm tuyau en PVC vous incombant tuyau en PVC NW 50 ND 6 5a pi ce sceller 4a liner paroi bouchon 2 cadre de serrage fond bassin tuyau d aspiration d air pour la pris...

Страница 24: ...rrer fortement Etancher le raccord double 20 la vanne 21 le coude sp cial 90 22 et le tuyau d aspiration 23 Serrer la pompe 24 sur un socle b ton ou mayonn l aide des vis d ancrage livr es avec le dis...

Страница 25: ...25 7...

Страница 26: ...tique partir du bassin Accessoire image num ro 7a ex cution en bronze au zinc en ABS Retirer le presse toupe 40 de la pi ce sceller 41 en le tournant vers la gauche et enlever la rondelle plastique d...

Страница 27: ...27 7a 49 48 44 26 33 35 47 50 43 40 42 46 41 45 25 24 16 13 12 8 7 32 34 15 14 4 3 1 10 5 2 9 6...

Страница 28: ...28 ID NR 186 817 09 2005 uwe GmbH Buchstra e 82 Postfach 2020 D 73510 Schw bisch Gm nd Tel 07171 103 0 Fax 07171 103 106...

Отзывы: